ACD heat pumps in Montreal: a checked passport for every system
Three wall units that heat down to -20 °C, -25 °C (9,000 to 24,000) or -30 °C, a multi-zone system for 2 to 5 rooms and a FLEXX central system down to -30 °C. Pick a system: its passport shows what is certified, what qualifies for LogisVert and what the warranty covers.
UHD
Révolution · 12,000 BTU/h
An ACD machine, a local team.
ACD puts its name on the heat pump, from the Éclypse wall unit to the FLEXX central. AirGreen comes to see the house, chooses the system with you and installs it. Each does what it does best.
What ACD brings
- Down to -30 °CThe Révolution wall unit and the FLEXX central keep heating down to that, per ACD’s brochures.
- Three wall units, three wintersÉclypse down to -20 °C, Commodore23 down to -25 °C (9,000 to 24,000), Révolution down to -30 °C.
- A multi-zone for 2 to 5 roomsWall, ducted, cassette, console or floor-ceiling heads on the same MPD outdoor unit.
- 10 years on parts and compressorResidential use in Québec, from the original installation.
What AirGreen brings
- Sold and installed by AirGreenMontreal, Laval, Longueuil, the South Shore and the North Shore.
- Free home estimateWe visit your home and choose the system with you.
- A clear quoteAnd the AHRI number on our system pages, so you can check ENERGY STAR and Hydro-Québec yourself.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: the right ACD, chosen with you on checked numbers and installed by AirGreen.
Eight families, one brand, one warranty.
Wall units, multi-zone, central and indoor heads: everything we install from ACD, with a link to each collection.
Éclypse, Commodore23 or Révolution: one brand, three different winters.
Pick a size. Figures come from ACD’s brochures and, when the model is certified, from ENERGY STAR and Hydro-Québec. Green marks the best value in each row.

Éclypse
ACD’s entry model
Commodore23
The middle, up to 36,000
Révolution
The deep-cold modelSEER and HSPF: ACD brochures. Commodore23: -25 °C published from 9,000 to 24,000; -20 °C for the 30,000 and 36,000 per their manual. SEER2, HSPF2 and heat at -15 °C: ENERGY STAR dataset w7cv-9xjt, certified capacities at 5 °F; heat at -8 °C for the Révolution: maximum listed on NEEP (records 406806, 406805, 406804), ENERGY STAR or NEEP nominal rating in parentheses. LogisVert: indicative amount, Hydro-Québec list checked on October 13, 2026.
Slide the thermometer: see which ACD systems still heat.
Each bar ends at the minimum outdoor heating temperature published by ACD. Below it, another heat source is needed.
Sources: ACD brochures for Éclypse, Commodore23, Révolution, MPD and FLEXX. Commodore23: -25 °C published from 9,000 to 24,000; -20 °C for the 30,000 and 36,000 per their manual. The FLEXX brochure states 100% efficiency at -20 °C and 78% at -30 °C.
Build your rooms: we tell you which MPD compressor accepts them.
One outdoor unit for 2 to 5 rooms. Pick the type and size of each head: the tool checks the combination against ACD’s published tables and refuses the ones that are not listed.
Sizes offered by ACD: wall 9,000 to 24,000, ducted 9,000 to 24,000, cassette 12,000 to 24,000, console 9,000 and 12,000, floor-ceiling 9,000 to 24,000 BTU/h.
Recommended compressor
3 heads: 9,000 + 9,000 + 12,000. It is the smallest compressor whose ACD table accepts this combination (MPD24KCH21S).
LogisVert: not eligible (no ENERGY STAR record); the MPD compressors on our pages are not on Hydro-Québec’s list checked on October 13, 2026.
Request my estimateFive ways to deliver air, all connected to an MPD.
At ACD, the cassette, ducted, console and floor-ceiling units exist only as heads of the MPD multi-zone. We mix them with wall heads to suit each room.
On your ducts, down to -30 °C: the FLEXX, from 2 to 5 tons.
An FXD outdoor unit and an AH indoor air handler that takes the furnace’s place. All four sizes are ENERGY STAR cold-climate certified and on the LogisVert list.

Outdoor FXD-ACD36

Air handler AH236
FLEXX · 3 tons
Six ACD systems on Hydro-Québec’s list. We also tell you about the rest.
Since November 26, 2025, Hydro-Québec only accepts ENERGY STAR heat pumps. Every AHRI number on our ACD product pages was looked up in Hydro-Québec’s list on October 13, 2026; every amount shown is an indicative amount. Only Hydro-Québec confirms the assistance granted.
Certified heating capacity at -8 °C, divided by 1,000, times $120 for an ENERGY STAR cold-climate unit, or $50 for another ENERGY STAR unit. Example: FLEXX 5 tons, 44,000 ÷ 1,000 × $120 = $5,280, an indicative amount.
ENERGY STAR required; outdoor unit of at least 12,000 BTU/h; aid capped at 100% of the pre-tax cost; claim within 9 months of installation. Residential participation guide v1.10, Sept. 15, 2026.
Ten years on parts and compressor. Here is what comes with it.
Summary of the ACD standard warranty for R-410A equipment. Pick the use: the terms change.
on parts and compressor, from the original installation
ACD standard warranty for equipment installed in a residential home in Québec.
Installed per the instructions, codes and industry standards.
Done per the manual; otherwise the warranty can be voided in whole or in part.
For ACD equipment installed in Québec.
ACD R-410A equipment: Éclypse, Commodore23, Révolution, MPD and FLEXX.
Without a verifiable date, it starts 3 months after the manufacturing date.
The document asks for no online registration.
Not covered by the ACD standard warranty.
The warranty no longer applies if it is removed, reinstalled or modified without authorization.
Source: ACD R410 standard warranty, bilingual (file online since Sept. 22, 2025, no printed date); commercial use: ACD brochure footnotes. The warranty mentions no registration.
How to read ACD model numbers.
- Warranty: the ACD standard warranty, for ACD equipment installed in Québec after January 1, 2021.
- Refrigerant: the whole ACD lineup runs on R-410A (GWP of 2,088 per ENERGY STAR).
- Certifications: ENERGY STAR lists the Révolution 12,000 and 24,000 and the four FLEXX central systems on our pages; no Éclypse or Commodore23 model.
| Prefix | Family | Heats down to |
|---|---|---|
SED | Éclypse | -20 °C |
OCD | Commodore23 and MPD wall head | Single-zone: -25 °C published from 9,000 to 24,000; -20 °C for the 30,000 and 36,000 per their manual |
UHD | Révolution | -30 °C |
MPD | Multi-zone, outdoor unit | -20 °C |
SMD · CCD · CMD · FCD | Ducted, cassette, console, floor-ceiling heads | per the MPD |
FXD + AH | FLEXX central | -30 °C |
What people ask us about ACD.
AirGreen sells and installs the whole ACD range across Montreal, Laval, Longueuil, the South Shore and the North Shore. ACD’s brochures give the limits and efficiencies; the AHRI certificates and the NEEP and ENERGY STAR records, quoted by number on our product pages, let you check each listed system.
Your ACD, chosen on checked numbers.
We visit the house, choose the system with you and hand you a clear quote.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.
Sources checked on October 7 and 13 and November 5, 2026
- ACD product pages and terms (Éclypse, Commodore23, Révolution, MPD, FLEXX, multi-zone heads), viewed Oct. 7, 2026.
- ACD brochures: Éclypse, Commodore23 and Révolution series (FR), Multi-Zone System (MPD, EN), FLEXX central (FR).
- ACD Commodore23 30,000 and 36,000 manual.
- ACD R410 standard warranty (bilingual).
- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, queried Oct. 13, 2026 (AHRI numbers of the ACD pages).
- NEEP cold-climate heat pump list, records 406804, 406805, 406806 and 406031 to 406034, read on November 5, 2026.
- Hydro-Québec, LogisVert residential participation guide, version 1.10, Sept. 15, 2026.
- Hydro-Québec, eligible heat pump search tool: list checked on October 13, 2026, search by AHRI number.
- airgreen.ca ACD product pages (AHRI and model numbers), Oct. 13, 2026.
LogisVert amounts are indicative: Hydro-Québec confirms them when you file. Price on quotation.
Every ACD product we carry, right below.
Wall units, MPD multi-zone systems, FLEXX central systems and their air handlers, ducted units, floor-ceiling units, cassettes and consoles: filter by type, capacity or number of zones, then compare the product pages.