AirGreenCanAir
AirGreen × CANAIR · 4C28 multi-zone · 6 roomsSix rooms on one unit: the top of the rangeSold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.
The full CanAir range
  1. Home
  2. CanAir
  3. 6-room multi-zone
CanAir · 4C28 multi-zone · 6 rooms

The maximum: six rooms on one outdoor unit.

The 4C28MC648 is the only 4C28MC unit that takes six heads. It puts out 47,000 BTU/h at -15 °C and heats down to -30 °C. One rule to know before you sign: all six rooms heat or cool together.

Updated October 27, 2026 · CanAir 4C28 brochure, ENERGY STAR, NEEP and Hydro-Québec’s LogisVert list

LivingKitchenMain bedroomBedroom 2OfficeBasement1 mode only
6heads at most on the 4C28MC648, per CanAir
47,000BTU/h at -15 °C for all heads together, per NEEP
24,600BTU/h still available at -30 °C, per NEEP
$5,400indicative LogisVert for the combination on our product pages (AHRI 215449733)
This page answers

For anyone who wants one heat pump to heat and cool six rooms, and wants to understand what that changes day to day and in deep cold.

The CanAir shop · 6-room multi-zone

The 6-room system, right below.

The 4C28MC648, with its AHRI number and indicative LogisVert amount.

01 · One mode

Six rooms, one mode: heat or cool, for all of them.

Each head keeps its own temperature, but the outdoor unit does one thing at a time. Set the six rooms and see what happens when they disagree, then what the unit puts out in deep cold.

An April afternoon

The sun warms the living room, the basement stays cool. Say what each room calls for.

Living roomsouth-facing
—
Kitchenoven on
—
Main bedroomnorth side
—
Bedroom 2door closed
—
Home officeshaded window
—
Basementcool all year
—

A scenario to show how a multi-zone works; your rooms’ real needs are assessed on site.

4C28MC648H21 · one mode
0to heat0to cool0off
—
——
——
——

Totals for all the heads that are running. Each head delivers at most its own size: with few heads running, their size is the limit, not the outdoor unit. Heat at -15 °C and -30 °C: NEEP, Oct. 27, 2026. Nominal cooling: CanAir 4C28 brochure.

See the 4C28MC648 page →
02 · The 648 up close

The biggest of our 4C28MC units, measured and in figures.

Drawn to scale, with its spec sheet and its three AHRI numbers.

37.48 in52.48 indepth 16.34 in
Heads1 to 6, from 6,000 to 33,000 BTU/h
Nominal cooling47,000 BTU/h (sold as 48,000)
Heat at -8.3 / -15 / -30 °C (NEEP)45,000 / 47,000 / 24,600
Heating rangedown to -30 °C
SEER2 / HSPF2 IV / HSPF2 V23.0 / 11.0 / 9.0
RefrigerantR-454B
Outdoor sound65.0 dB(A)
Max. fuse / min. ampacity40 A / 37 A
ENERGY STARCertified, cold climate
AHRI 215449733$5,40045,000 BTU/h
× $120 / 1,000
AHRI 215449734$5,52046,000 BTU/h
× $120 / 1,000
AHRI 215449735$5,46045,500 BTU/h
× $120 / 1,000

Size and min. ampacity: airgreen.ca product page. Head count, nominal, sound and fuse: CanAir 4C28 brochure (June 2025). Heat: NEEP, Oct. 27, 2026. SEER2 and HSPF2: ENERGY STAR and the brochure. LogisVert: Hydro-Québec list of Oct. 27, 2026, each number’s output at -8 °C × $120 / 1,000. Hydro-Québec sets the amount from the AHRI number of the combination installed. Heat: NEEP values as published, slightly higher at -15 °C than at -8.3 °C for this model.

03 · Good to know

Six rooms on one unit: four things to weigh.

What we tell you on site, before we even talk sizes.

One mode for the whole house

The 4C28MC heats or cools, for all its heads at once. In spring and fall, when the living room is warm and the basement cold, you have to pick one.

One unit, six rooms that depend on it

If the outdoor unit stops, all six heads stop with it. CanAir’s base warranty covers the compressor and parts for 10 years on residential systems sold since October 5, 2026.

The tallest 4C28MC

52.48 in. tall per our product page, 65 dB(A) per the brochure: its spot is picked with care, for clearance, snow and your city’s by-law.

Six lines to one point

Each head connects to the outdoor unit. Routes and lengths are planned room by room, per CanAir’s manual.

04 · Questions

What people ask us about six rooms.

How many heads does the 4C28MC648 take?
Up to six, per the CanAir 4C28 brochure: its combination table runs from one to six heads. It is the only one of our 4C28MC units that goes to six.
Can the basement heat while upstairs cools?
No. The outdoor unit heats or cools for all heads at once. Each room still keeps its own setpoint.
What do six rooms get in deep cold?
Per NEEP, the 4C28MC648 puts out at most 47,000 BTU/h at -15 °C and 24,600 BTU/h at -30 °C for all the heads running together. Each head delivers at most its own size.
What LogisVert amount for a 6-room system?
One indicative amount for the system: $5,400 for the combination on our product pages (AHRI 215449733), $5,460 or $5,520 for the two other combinations on Hydro-Québec’s list of October 27, 2026. The AHRI number is written on the quote, and Hydro-Québec confirms the amount.
Can I start with fewer than six heads?
CanAir’s combination table runs from one to six heads on the 4C28MC648. If six rooms are not planned, a smaller unit may do: we compare on site.
Which head sizes go on the 4C28MC648?
From 6,000 to 33,000 BTU/h, per our product page. Your six-head combination is checked against CanAir’s table.
What does the warranty cover on the 4C28MC648 and its heads?
CanAir’s base warranty, for a residential system sold since October 5, 2026: 10 years on the compressor and parts, and 6 years of limited labour for a residential install in Quebec, per the maker’s hours schedule. CanAir also offers a 4-year labour extension, as an option, for the original buyer only.
AirGreen · Air conditioning & heating

Six rooms, one unit: planned with you, room by room.

Six rooms means six line routes and a 52-inch-tall unit to place. We map them with you on site, then the quote lists each head’s size, the AHRI number and the indicative LogisVert amount.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Free estimateAt home, no commitment
LogisVert checkedBy AHRI number, on Hydro-Québec’s list
Showroom1370 Joliot-Curie St., Suite 712, Boucherville

Heads-up: Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. If a call “from Hydro-Québec” tries to sell you a heat pump, hang up.

Sources checked on October 27, 2026

  • CanAir 4C28 R-454B brochure (June 2025), multi-zone section; dealer copy, only legible values used.
  • NEEP cold-climate air-source heat pump list (ashp.neep.org), read October 27, 2026.
  • ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, read Oct. 8, 2026.
  • Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 27, 2026.
  • LogisVert residential participation guide, version 1.10, September 15, 2026.
  • CanAir base warranty 2026-10-05 (consumer) and 4-year extended labour warranty 2026-10-05.
  • airgreen.ca product pages, Oct. 27, 2026.

LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote; free in-home estimate.