AirGreenCanAir
AirGreen × CANAIR · 4C28 multi-zone · 5 roomsFive rooms: heads or ductsSold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.
The full CanAir range
  1. Home
  2. CanAir
  3. 5-room multi-zone
CanAir · 4C28 multi-zone · 5 rooms

Five rooms: five heads, or your ducts?

At five rooms, two CanAir systems hold up on paper: a 4C28MC multi-zone with one head per room, or a 4CDH central system that runs through the ducts. Both heat down to -30 °C. What decides it is your house.

Updated October 27, 2026 · CanAir 4C28 and 4CDH brochures, ENERGY STAR, NEEP and Hydro-Québec’s LogisVert list

or5 headsDucts
24C28MC outdoor units take five heads: the 536 and the 648
47,000BTU/h at -15 °C for the 4C28MC648, per NEEP
39,000BTU/h at -15 °C for the 3-ton 4CDH central, per CanAir
$4,560indicative LogisVert for the 4C28MC536, one amount for the system
This page answers

For anyone heating and cooling five rooms or more who is torn between a wall head in every room and a central system that uses the ducts.

The CanAir shop · 5-room multi-zone

The 2 five-room systems, right below.

The 4C28MC536 and the 4C28MC648, each with its AHRI number and indicative LogisVert amount.

01 · Your route

Four answers, and your house picks the route.

Ducts or not, a furnace or not, heads on the wall or grilles: the tool tells you which CanAir route holds up in your home, and puts the two systems side by side.

Does your house have air ducts?

How is the house heated today?

In the rooms, you would rather have…

Size to compare

The right size is worked out at your home, room by room; these two pairs compare systems of similar output.

—

—

—

At this size——
02 · Side by side

Two multi-zones, three centrals: the figures, unrounded.

CanAir systems of comparable output, side by side. Each indicative LogisVert amount links to the product page.

SystemIn the roomsNominalHeat at -15 °CHeat at -30 °CSEER2 /
HSPF2 IV
LogisVert
4C28MC536H21
Multi-zone, up to 5 heads
One wall head per room36,000 BTU/h36,000 BTU/h22,400 BTU/h23.0 / 10.7$4,560
4C28MC648H21
Multi-zone, up to 6 heads
One wall head per room47,000 BTU/h47,000 BTU/h24,600 BTU/h23.0 / 11.0$5,400 – $5,520
4CDH 3 tons
Central, indoor unit 4CDH2036F21
Your duct grilles36,000 BTU/h39,000 BTU/h27,800 BTU/h17.3 / 10.3$3,816
4CDH 4 tons
Central, indoor unit 4CDH2048F21
Your duct grilles48,000 BTU/h46,000 BTU/h25,900 BTU/h16.5 / 9.5$4,740
4CDH 5 tons
Central, indoor unit 4CDH2060F21
Your duct grilles54,000 BTU/h52,000 BTU/h30,900 BTU/h16.0 / 9.0$5,400

Multi-zone: one setpoint per room

Each head keeps its own temperature, but all five follow the same mode: heating or cooling.

Central: the air runs through your ducts

One multi-position indoor unit, in the basement or a closet. Wi-Fi wired controller included, per the 4CDH brochure.

Central: backup inside the unit

The 4CDH indoor unit takes 5 to 25 kW electric elements, as an option. The panel is checked on site.

Multi-zone: nominal, head count and sound, CanAir 4C28 brochure (June 2025). Central: CanAir 4CDH brochure (revised July 18, 2025), including heat at -15 °C. Heat at -30 °C: NEEP, Oct. 27, 2026. SEER2 and HSPF2 (region IV): ENERGY STAR and the 4CDH brochure. LogisVert: Hydro-Québec list of Oct. 27, 2026; for the 4C28MC648, the amount depends on the combination’s AHRI number.

03 · 536 or 648

The 536 fills up at five. The 648 keeps one in reserve.

Both units drawn to the same scale, with their ports: solid for your five rooms, dotted for what is left.

4C28MC536H21

Five heads: every port is taken.

Height (product page)38.39 in
Heat at -15 °C / -30 °C36,000 / 22,400
LogisVert$4,560
Max. fuse40 A
Outdoor sound65.0 dB(A)
See the page →

4C28MC648H21

1 free port

Five heads, with one port left for a sixth room, if CanAir’s table allows it.

Height (product page)52.48 in
Heat at -15 °C / -30 °C47,000 / 24,600
LogisVert$5,400 – $5,520
Max. fuse40 A
Outdoor sound65.0 dB(A)
See the page →

Height: airgreen.ca product pages. Head count, fuse and sound: CanAir 4C28 brochure (June 2025). Heat: NEEP, Oct. 27, 2026. LogisVert: Hydro-Québec list of Oct. 27, 2026.

04 · Questions

What people ask us before choosing.

Five heads or a central: which heats better at -30 °C?
Both heat down to -30 °C. Per NEEP, maximum output at -30 °C is 22,400 BTU/h for the 4C28MC536 and 24,600 for the 4C28MC648; 27,800 for the 3-ton 4CDH central, 25,900 for the 4-ton and 30,900 for the 5-ton. The right choice depends mostly on your ducts and your rooms.
My house has no ducts. Is a central system possible?
A central system needs ductwork to deliver the air. Without ducts, the multi-zone is the direct route: one wall head per room, one unit outside.
I have a gas or oil furnace. What are my options?
Two routes: the CanAir add-on keeps your furnace and adds a heat pump and coil to it, or a multi-zone is added without going through the furnace. AirGreen installs the heat pump; we do not work on the burner or the gas or oil supply: a partner holding the required licence handles that if needed.
Is the 4C28MC536 enough for five rooms?
It takes five heads at most, for 36,000 BTU/h nominal. If the heads add up to more than that, each head delivers less, mostly in heating, per CanAir. The sizing is worked out room by room on site.
Does a 4CDH central qualify for LogisVert?
Yes, per Hydro-Québec’s list of October 27, 2026, as indicative amounts: $3,816 for the 3-ton, $4,740 for the 4-ton and $5,400 for the 5-ton. On the multi-zone side, the 4C28MC536 is at $4,560 and the 4C28MC648 at $5,400 for the combinations on our product pages.
Can I keep my baseboards with a multi-zone?
The multi-zone does not require removing them. What stays and what goes is decided with you on site.
With five heads, does each room get its own temperature?
Yes, each head keeps its own setpoint. All five heat or cool at the same time: you cannot heat one room and cool another at the same moment.
What warranty, either way?
Compressor and parts: 10 years either way, for residential use, per CanAir’s base warranty. Labour: 6 years limited for a multi-zone sold since October 5, 2026; for the 4CDH central system, we confirm it in writing on the quote.
AirGreen · Air conditioning & heating

Heads or ducts: we settle it at your home, room by room.

We look at your ducts, your furnace and each room, then hand you a clear quote for the route that holds up, with the AHRI number and the indicative LogisVert amount. If both hold up, we price both.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Free estimateAt home, no commitment
LogisVert checkedBy AHRI number, on Hydro-Québec’s list
Showroom1370 Joliot-Curie St., Suite 712, Boucherville

Heads-up: Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. If a call “from Hydro-Québec” tries to sell you a heat pump, hang up.

Sources checked on October 27, 2026

  • CanAir 4C28 R-454B brochure (June 2025), multi-zone section; dealer copy, only legible values used.
  • CanAir 4CDH R-454B brochure (revised July 18, 2025).
  • NEEP cold-climate air-source heat pump list (ashp.neep.org), read October 27, 2026.
  • ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, read Oct. 8, 2026.
  • Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 27, 2026.
  • LogisVert residential participation guide, version 1.10, September 15, 2026.
  • CanAir base warranty 2026-10-05 (consumer) and 4-year extended labour warranty 2026-10-05.
  • airgreen.ca product pages, Oct. 27, 2026.

LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote; free in-home estimate.