AirGreenCanAir
AirGreen × CANAIR · 4C22 series · R-454BCanAir’s compact wall unit, by night and by daySold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.
The full CanAir range
  1. Home
  2. CanAir
  3. Wall units
  4. 4C22
CanAir · 4C22 wall unit · R-454B

Turned down low: the 4C22 goes as quiet as 17.5 dB(A).

Five compact wall units from 9,000 to 18,000 BTU/h, on R-454B, two of them on 115 V. In silent speed, the 12,000 115 V is rated at 17.5 dB(A), per the CanAir brochure.

Updated October 27, 2026 · CanAir 4C22 brochure, ENERGY STAR, NEEP and Hydro-Québec’s LogisVert list

zz17.5dB(A)silent speed, 12,000 · 115 V
17.5dB(A) indoors, 12,000 · 115 V in silent speed, per CanAir
52.5dB(A) outdoors for the 9,000 · 115 V: the quietest outdoor unit in the CanAir wall-unit brochures
-15 °Cheating, on all 5 models, per the brochure table
$996–$1,680indicative LogisVert with the “-P” indoor unit, list of Oct. 27, 2026
This page answers

For anyone who wants a compact R-454B wall unit for a bedroom, an office or the shoulder seasons, and wants to know how it behaves at night, in the cold and for LogisVert.

The CanAir shop · 4C22

All five 4C22 wall units, right below.

From 9,000 to 18,000 BTU/h, on 115 V or 230 V. Each page lists the AHRI number.

01 · Night mode

Pick a size and a speed: the needle shows the published level.

The 4C22 brochure publishes five fan speeds, from turbo down to silent, with the sound level of each.

Size and voltage

Fan speed

—
—dB(A)

—

Outdoor unit—
Same unit, in turbo—
Quietest at this speed—
See this model’s page →

—

Indoor sound levels in dB(A) by speed, and the outdoor unit level: CanAir 4C22 brochure (June 2025), p. 5. Rule of thumb: 10 dB(A) more sounds about twice as loud. dB(A) is weighted to follow the ear’s sensitivity.

02 · The “-P” version

Same outdoor unit, another head: the letter P is what opens LogisVert.

On June 9, 2026, ENERGY STAR certified 4C22 indoor heads whose model ends in “-P”, all of them cold climate. With them, the 12,000 (115 V and 230 V) and the 18,000 are on Hydro-Québec’s LogisVert list. The AHRI numbers on our current product sheets are not.

Your 4C22

Current product sheet

—

Indoor unit—
LogisVert—
“-P” version

—

Indoor unit—
LogisVert—
Indicative LogisVert amount
—

—

See this model’s page →

Who decides: the AHRI number on your invoice. We confirm with the distributor which version is delivered (with or without “-P”) and write it on the quote. The 9,000 has no amount either way: it is under the 12,000 BTU/h minimum.

Amounts and -8 °C outputs: Hydro-Québec LogisVert list of October 27, 2026 (identical to the October 8 list). “-P” certification: ENERGY STAR, read Oct. 8, 2026. Rate: $120 per 1,000 BTU/h at -8 °C, LogisVert residential participation guide, version 1.10, September 15, 2026.

03 · In the cold

At -15 °C, the 4C22 gives 6,500 to 11,500 BTU/h.

A shoulder-season and backup wall unit: it heats down to -15 °C, with a COP of 1.84 to 2.15 at that temperature.

Heat at -15 °C, size by size

9,000 · 115 VCOP 1.96
6,500 BTU/h
9,000 · 230 VCOP 2.07
7,000 BTU/h
12,000 · 115 VCOP 1.84
6,600 BTU/h
12,000 · 230 VCOP 1.91
8,000 BTU/h
18,000 · 230 VCOP 2.15
11,500 BTU/h

Rated output and COP at -15 °C: CanAir 4C22 brochure (June 2025), p. 5. COP compares heat delivered with electricity used; baseboard heat gives 1.

Below -15 °C, another heat source takes over

The published heating range runs from -15 °C to 24 °C. Colder than that, your baseboards or current system heat the room. To heat all winter with the wall unit, the 4C28 goes down to -30 °C.

See the 4C28, down to -30 °C

04 · R-454B

The C22 on R-410A, the 4C22 on R-454B: same job, another gas.

The 4C22 takes over the C22’s compact sizes with a refrigerant whose global warming potential is about 4.5 times lower.

Global warming potential (GWP, 100 years)

R-410AC22 · C28
2,088
R-454B4C22 · 4C28 · 4CDH
466

÷ 4.5 when moving to R-454B

100-year GWP, IPCC Fourth Assessment Report (AR4): R-410A 2,088, R-454B 466. Refrigerant by series: CanAir brochures.

A2L

Class A2L, printed on the brochure

The 4C22 brochure prints “A2L R-454B” (p. 5). A2L means low toxicity and mildly flammable. We install it following the rules set for that class.

What changes for you

In use, nothing: the unit heats and cools the same way. The refrigerant matters mostly for the environment and for the technician who services it.

See its twin, the C22

05 · Region IV or V

Two HSPF2 figures on the brochure: region V is the colder of the two.

HSPF2 measures heating efficiency over a season. Most spec sheets give only region IV; the 4C22 brochure also publishes region V, a colder climate. Switch to compare.

HSPF2 in region IV and region V: CanAir 4C22 brochure (June 2025), p. 5. Our product pages show the region IV value.

06 · On 115 V

Two 4C22 units run on 115 V: the 9,000 and the 12,000.

Same size, two voltages. Here are the published differences, side by side. The 12,000 on 115 V is the quietest in silent speed; the 230 V keeps better heating efficiency.

9,000 BTU/h: 115 V · 230 V

4C22SCH09H11 · 4C22SCH09H21

SEER221.5 · 21.2
EER212.5 · 12.6
HSPF2 region IV9.0 · 9.1
Heat at -15 °C6,500 · 7,000
Sound, silent speed18.0 · 18.5
Outdoor sound52.5 · 53.5
Max. circuit protection (sheet)20 A · 15 A

12,000 BTU/h: 115 V · 230 V

4C22SCH12H11 · 4C22SCH12H21

SEER221.2 · 21.3
EER210.1 · 10.8
HSPF2 region IV8.7 · 9.1
Heat at -15 °C6,600 · 8,000
Sound, silent speed17.5 · 21.0
Outdoor sound54.0 · 54.0
Max. circuit protection (sheet)20 A · 15 A

Your panel decides. Choosing 115 V or 230 V mostly depends on the room and the circuit available in your electrical panel. AirGreen holds subclass 16 (electrical) of its RBQ licence 5645-9605-01: we check it during the visit.

Efficiencies, heat at -15 °C and sound: CanAir 4C22 brochure (June 2025), p. 5. Max. circuit protection: airgreen.ca product pages, Oct. 27, 2026. Values given as 115 V · 230 V.

07 · Questions

What people ask us about the 4C22.

Which 4C22 is the quietest?
The 12,000 on 115 V: 17.5 dB(A) in silent speed, per the CanAir brochure. The 9,000 115 V follows at 18.0, the 9,000 230 V at 18.5.
Does the 4C22 qualify for LogisVert?
Only with the “-P” indoor unit: $1,080 for the 12,000 115 V, $996 for the 12,000 230 V and $1,680 for the 18,000, per Hydro-Québec’s list of October 27, 2026. The 9,000 has no amount.
Why does the 12,000 on 230 V get less than the 115 V?
The amount follows the heating output certified at -8 °C: 8,300 BTU/h for the 230 V “-P”, 9,000 for the 115 V “-P”. At $120 per 1,000 BTU/h, that gives $996 and $1,080.
How cold can the 4C22 heat?
Down to -15 °C, per the CanAir brochure table. Colder than that, another heat source takes over.
How is it different from the C22?
The refrigerant: R-454B for the 4C22, R-410A for the C22. Both heat down to -15 °C. The C22 goes up to 24,000 BTU/h; the 4C22 stops at 18,000 and publishes a silent speed.
Is Wi-Fi available?
Yes, as an option: the 4C22 brochure lists Wi-Fi control as optional. We discuss it at the quote.
Is R-454B safe in a bedroom?
It is classed A2L: low toxicity, mildly flammable. The brochure states it, and we install it following the rules set for that class.
What warranty covers a 4C22?
The same CanAir base warranty as the other wall units: 10 years on the compressor and parts, and 6 years of limited labour, for a residential system sold since October 5, 2026 and installed in Quebec.
AirGreen · Air conditioning & heating

Your 4C22, chosen for the room you sleep in.

We come and see the room and the panel, choose the size and voltage with you, and hand you a clear quote with the AHRI number of the version delivered.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Free estimateAt home, no commitment
LogisVert checkedBy AHRI number, on Hydro-Québec’s list
Showroom1370 Joliot-Curie St., Suite 712, Boucherville

Heads-up: Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. If a call “from Hydro-Québec” tries to sell you a heat pump, hang up.

Sources checked on October 27, 2026

  • CanAir 4C22 R-454B brochure (June 2025), p. 5.
  • ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, read Oct. 8, 2026.
  • NEEP cold-climate air-source heat pump list (ashp.neep.org), read October 27, 2026.
  • Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 27, 2026.
  • LogisVert residential participation guide, version 1.10, September 15, 2026.
  • 100-year GWP, IPCC Fourth Assessment Report (AR4): R-410A 2,088, R-454B 466.
  • CanAir base warranty 2026-10-05 (consumer) and 4-year extended labour warranty 2026-10-05.
  • airgreen.ca product pages, Oct. 27, 2026.

LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote; free in-home estimate.