The C28 9,000: SEER2 28.1, the best cooling efficiency of our 22 wall units.
Six sizes from 9,000 to 36,000 BTU/h. From 9,000 to 24,000 it heats down to -30 °C and is ENERGY STAR cold climate. The 30,000 and 36,000 stop at -15 °C: we show you the difference.
Updated October 27, 2026 · CanAir C28 brochure, ENERGY STAR and Hydro-Québec’s LogisVert list
For anyone who wants the wall unit that uses the least power to cool, and wants to know which C28 units really heat in winter.
The 6 C28 wall units, right below.
From 9,000 to 36,000 BTU/h, all on 230 V. Each page lists the AHRI number and the indicative LogisVert amount.
Same comfort, less electricity: put the C28 up against any CanAir wall unit.
Pick a C28, then another unit from the range. For the same cooling (SEER2) or the same heating season (HSPF2), we work out the electricity saved, or added. The math is shown.
Your C28
Compared with
For
—
Ratio of published seasonal ratings, for equal use: an indication, not a bill. Real use depends on the house, the climate and the size chosen.
See this C28’s page →SEER2 and HSPF2 (region IV): CanAir C22 (p. 7), C28 (p. 4), 4C22 (p. 5) and 4C35-28-25 (p. 11) brochures. For the same energy delivered, consumption varies inversely with the rating: 1 ÷ SEER2, 1 ÷ HSPF2. Region IV is a milder climate than Montreal, and the rating does not count the backup heat needed below -15 °C for the C22, the 4C22 and the C28 30,000 and 36,000.
From 9,000 to 24,000: -30 °C. In 30,000 and 36,000: -15 °C.
Same series name, two behaviours in deep cold. The CanAir brochure says so size by size; we put it side by side.
C28 9,000, 12,000, 18,000 and 24,000
C28 30,000 and 36,000
Ranges: CanAir C28 brochure (January 31, 2025), p. 4. ENERGY STAR: dataset read Oct. 8, 2026. Heat at -15 °C: ENERGY STAR (9,000 to 24,000). LogisVert: Hydro-Québec list of Oct. 27, 2026; the 9,000 is under the 12,000 BTU/h minimum.
At -15 °C, each kWh of electricity gives back 1.80 to 2.21 in heat.
COP compares heat delivered to electricity used. Electric baseboard heat gives 1 kWh of heat per kWh: that is the benchmark.
—
Heat and COP at -15 °C (5 °F), at maximum output: NEEP, read Oct. 27, 2026, for the 9,000 to 24,000 (ENERGY STAR lists the same outputs). For the 30,000 and 36,000, COP from the CanAir C28 brochure, p. 4; their heat at -15 °C is published neither in the brochure nor by ENERGY STAR, and their heating range ends at -15 °C.
Three C28 units have an amount: $1,200, $1,800 and $2,544.
$120 per 1,000 BTU/h of output at -8 °C, for an ENERGY STAR cold-climate heat pump of 12,000 BTU/h or more. The other three C28 units miss out, for two different reasons.
Amounts and output at -8 °C: Hydro-Québec LogisVert list of October 27, 2026 (owner, existing home), same as October 8. Rules: LogisVert residential participation guide, version 1.10, September 15, 2026. Hydro-Québec confirms the amount when you apply.
C28 or 4C28: same cold, different refrigerant, different strengths.
The four sizes they share, figure against figure. The green dot marks the better of the two.
| Size | SEER2 | HSPF2 IV | Heat at -15 °C | LogisVert | ||||
|---|---|---|---|---|---|---|---|---|
| C28 | 4C28 | C28 | 4C28 | C28 | 4C28 | C28 | 4C28 | |
| 9,000 BTU/h | 28.1 | 27.4 | 11.5 | 12.5 | 10,600 | 11,500 | — | — |
| 12,000 BTU/h | 25.5 | 25.4 | 10.4 | 10.5 | 12,000 | 11,500 | $1,200 | $1,440 |
| 18,000 BTU/h | 21.5 | 21.4 | 11.3 | 11.0 | 18,000 | 18,000 | $1,800 | $2,160 |
| 24,000 BTU/h | 21.5 | 21.0 | 11.4 | 13.5 | 25,000 | 24,200 | $2,544 | $2,664 |
The C28 wins on cooling
Its SEER2 is higher in all four shared sizes: 28.1 vs 27.4 in 9,000, and the gap stays in its favour up to 24,000.
The 4C28 wins on LogisVert
Its amounts are higher in 12,000, 18,000 and 24,000 ($1,440, $2,160 and $2,664), and its range goes up to 33,000 BTU/h, every size heating down to -30 °C.
The refrigerant
R-410A for the C28 (GWP 2,088), R-454B for the 4C28 (GWP 466). GWP measures the climate effect of a leak over 100 years: the R-454B figure is about 4.5 times lower (our calculation).
CanAir C28 (p. 4) and 4C35-28-25 (p. 11) brochures; heat at -15 °C: ENERGY STAR (C28) and brochure (4C28); LogisVert: Hydro-Québec list of Oct. 27, 2026; GWP: IPCC AR4.
What people ask us about the C28.
Which C28 is the most efficient?
Do all C28 units heat down to -30 °C?
Why do the C28 30,000 and 36,000 get no LogisVert amount?
How much does LogisVert pay for a C28?
What does a SEER2 of 28.1 mean?
C28 or 4C28?
Does the C28 have Wi-Fi?
What does the C28 warranty cover?
Your C28, picked for its efficiency, in the right size.
We come and see the room, check whether a C28 from 9,000 to 24,000 is enough for your winter, and hand you a clear quote with the AHRI number and the indicative LogisVert amount.
Heads-up: Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. If a call “from Hydro-Québec” tries to sell you a heat pump, hang up.
Sources checked on October 27, 2026
- CanAir C28 R-410A brochure (January 31, 2025), pp. 4–5.
- CanAir C22 R-410A brochure (January 31, 2025), p. 7.
- CanAir 4C22 R-454B brochure (June 2025), p. 5.
- CanAir 4C35-28-25 wall heat pump brochure (version 2026-10-05), pp. 8, 11, 12.
- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, read Oct. 8, 2026.
- Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 27, 2026.
- LogisVert residential participation guide, version 1.10, September 15, 2026.
- 100-year GWP, IPCC Fourth Assessment Report (AR4): R-410A 2,088, R-454B 466.
- CanAir base warranty 2026-10-05 (consumer) and 4-year extended labour warranty 2026-10-05.
- airgreen.ca product pages, Oct. 27, 2026.