AirGreenKINGHOME
KINGHOME · AIRY R32The KINGHOME space at AirGreenSold and installed by AirGreen · Montreal, Laval, Longueuil, South Shore and North Shore
KINGHOME warranty
AirGreen × KINGHOMESold and installed by AirGreenAIRY R324 modelsUp to 30 SEER211.2 HSPF2G-Storm compressorMontreal · Laval · Longueuil · South Shore · North Shore
01 · Spec plate

One plate per model, and the difference against the Polaris.

Pick a model: identity, certified heating, NEEP curve, efficiency, power, sound at each speed and installation. “Not published” means Kinghome does not give the figure.

Kinghome Airy R32 wall heat pump 12,000 BTU/h
Airy R32

Airy 12,000 BTU/h · 220 V

KW12XQ29S1DI / KW12XQ29S1DO · See the product page

$1,560Indicative LogisVert, Hydro-Québec list of Oct. 26, 2026

Identity

Indoor unit
KW12XQ29S1DI
Outdoor unit
KW12XQ29S1DO
Compressor
G-Storm, up to 200 Hz (brochure)
AHRI (product page)
217903558
ENERGY STAR
4514303
Wi-Fi
included

Certified heating

Rated at -8.3 °C
13,000 BTU/h
COP at -8.3 °C
2.06
At -15 °C
12,200 BTU/h
COP at -15 °C
2
Cold climate
yes

ENERGY STAR

Heating per NEEP

8.3 °C
16,200 BTU/h · COP 3.77
-8.3 °C
13,000 BTU/h · COP 2.06
-15 °C
12,200 BTU/h · COP 2
-30 °C
8,500 BTU/h · COP 1.75
Min. at 8.3 °C
3,270 BTU/h
Turndown (NEEP)
3.73

Maximum heat published and COP.

Efficiency

SEER2
29.5
EER2
15.2
HSPF2 Region IV
10
HSPF2 Region V (Canada)
8

Power

Voltage
220 V
MCA / MOP
10 / 15 A
Voltage range
187-253 V
Power wire
14/3 AWG
Interconnecting wire
14/4 AWG

Sound and air

Indoor min. / max.
19 / 43 dB(A)
Indoor sound, 7 speeds
27 · 29 · 33 · 39 · 40 · 42 · 43 dB(A)Sleep to Turbo, submittal
Outdoor
55 dB(A)
Max. airflow
565 CFM

Installation

Liquid-gas line
1/4 - 1/2 in
Indoor W × D × H
38.19 × 10.13 × 13.66 in
Outdoor W × D × H
34.38 × 14.80 × 21.84 in
Line length
10-100 ft
Max. height difference
60 ft
Pre-charged for
24.6 ft (7.5 m)manual
Additional charge
0.2 oz/ft
Factory R-32 charge
35.3 oz
Net weight out. / in.
78.3 / 33.1 lb
Dehumidification
1.4 L/h
Min. height outside
45 cm (18 in)snow and defrost, submittal

Product page, 2026 Airy brochure, R32 Split Type manual and the model’s submittal (notes).

Against the Polaris 12,000 (220 V), its same-size sibling

Difference against the Polaris. See the Polaris.

  • -2,000BTU/h at -8.3 °C
  • -1,500BTU/h at -15 °C (ENERGY STAR)
  • +4SEER2
  • -8dB(A) at indoor minimum
  • 0dB(A) outside
  • $-240LogisVert
02 · Electricity

How much electricity for 1,000 kWh of heat?

HSPF2 says how much heat a heat pump gives per kilowatt-hour over a typical season. We use the Region V value, the Canadian climate one, and compare it with electric baseboards, which give 1 kWh of heat per kWh paid.

Size
Measure

03 · The -15 °C promise

“100% of its capacity at -15 °C”: we checked.

The Airy brochure says the G-Storm compressor “delivers 100% heating capacity at -15°C”. We took the certified figures on NEEP for each size and did the math two ways.

ModelRated at 8.3 °CMax. at -15 °CCOP at -15 °Cof sizeof rated at 8.3 °C100%?
Airy 9,00010,60011,5002.11128%108%yes
Airy 12,00012,20012,2002102%100%yes
Airy 18,00018,60018,0001.8100%97%97%
Airy 24,00024,00024,0001.8100%100%yes

NEEP, Airy records (rated and maximum heat, BTU/h; COP), re-read Oct. 26, 2026. “Of size”: ratio to the nominal size (9,000, 12,000…). “Of rated”: ratio to the rated heat at 8.3 °C (47 °F).

VerdictTrue for all four sizes against their nominal size. Against the rated heat at 8.3 °C, the 18,000 keeps 97%: 18,000 against 18,600 BTU/h. At 18,000 and 24,000, that is the strongest retention of our Kinghome wall units at -15 °C; at 9,000 and 12,000, the Polaris does better.
The AIRY shop

All Airy units, right below.

Filter by capacity, then open the product page: each one carries its AHRI number and, from 12,000 BTU/h, its indicative LogisVert amount.

KINGHOME
Everything to know

Everything to know about the Airy

Cold, noise at each speed, space inside and out, controls, what the technician must follow and the LogisVert calculation for each model.

04 · Deep cold

How much heat each Airy keeps when it freezes.

Slide toward the cold: the four Airy units show their maximum heat and COP per NEEP, down to -30 °C, their coldest certified point.

The NEEP curve, from 8.3 to -30 °C

05 · Noise

Each Airy’s sound, speed by speed.

Pick a model: its 7 speeds, from Sleep to Turbo, are placed on the Government of Québec scale, with the outdoor unit sound. Kinghome does not publish the test conditions: compare models with each other.

Model
20 dB(A)A whisper heard at one metre, a light wind in the trees
30 dB(A)A conversation in a low voice
40 dB(A)A library, a refrigerator, a quiet street at night
50 dB(A)Moderate rain, a washing machine
60 dB(A)A normal conversation
70 dB(A)A busy street, a vacuum cleaner

Scale: Québec.ca, “Mesure du bruit”, updated June 16, 2022. Levels: product pages (indoor minimum / maximum, outdoor).

06 · Dimensions

The Airy to scale, inside and outside.

Pick a model: the indoor and outdoor units are drawn to scale, the outdoor unit 45 cm (18 in) off the ground as the submittals ask.

Model

Dimensions: product pages (width × depth × height, inches). 45 cm (18 in) under the outdoor unit: submittals. 30 cm from the wall: Kinghome outdoor unit manual (Dec. 4, 2025). 1 ft grid.

07 · Controls and features

The remote, the optional controls and the Airy’s features.

The names are Kinghome’s own. Where the sheet gives no description, we say so.

Controls

  • YBE1FBFinfrared remote

Optional accessories:

  • XE71-44Gwired controller
  • XE74-44Eembedded wired controller
  • XE72-44Eembedded Wi-Fi wired controller
  • XE71-00/E24 V interlock wired controller

Included features

  • WI-FI controlWi-Fi control
  • 8C heating8 °C heating
  • I-feelKinghome’s name, no description on the sheet
  • Forced defrostforced defrost
  • Soft startsoft start
  • Self cleanself-cleaning
  • Low voltage startuplow-voltage start-up

Airy submittals, Kinghome Canada (March 13, 2026), read Oct. 26, 2026.

What the brochure highlights

08 · Technician’s corner

All four Airy units, installation side.

Pre-charged for 7.5 m (24.6 ft) of line per the manual, 25 ft per the brochure. The 24,000’s outdoor unit weighs 115.8 lb, almost as much as the Charmo 30,000 and 36,000 units (116.8 lb per their submittals). Torque, vacuum and clearances: on the wall units page.

ModelLine (ft)Height diff. (ft)Add. (oz/ft)Charge (oz)Outdoor wt (lb)Dehum. (L/h)Wires (AWG)
9,000 · 220 V10-100600.235.335s78.30.814/3 / 14/4
12,000 · 220 V10-100600.235.335s78.31.414/3 / 14/4
18,000 · 220 V10-131820.447.647s94.81.812/3 / 14/4
24,000 · 220 V10-131820.456.456s115.83.510/3 / 14/4

2026 Airy brochure. s: submittal (March 13, 2026), in small type when it differs from the brochure (charges rounded to the ounce). Additional charge: R32 Split Type manual. Wires: power / interconnecting. The English and French brochures print KW12XQ29S1DO as the 18,000’s outdoor unit: the product page, ENERGY STAR and NEEP say KW18XQ29S1DO. Outdoor unit at least 18 in (45 cm) above any surface, per the submittals.

Torque, vacuum and clearances

09 · LogisVert

The LogisVert of each Airy, with the calculation.

For an ENERGY STAR cold-climate heat pump, Hydro-Québec pays $120 per 1,000 BTU/h of heat at -8 °C, if the outdoor unit is at least 12,000 BTU/h. The rules and the deadline are on the Kinghome page.

ModelHeat at -8.3 °CCalculationLogisVert
Airy 9,000 · 220 V12,000 BTU/hnominal size under 12,000 BTU/hnot eligible
Airy 12,000 · 220 V13,000 BTU/h13,000 × $120 ÷ 1,000$1,560
Airy 18,000 · 220 V19,500 BTU/h19,500 × $120 ÷ 1,000$2,340
Airy 24,000 · 220 V23,000 BTU/h23,000 × $120 ÷ 1,000$2,760

Heat at -8.3 °C (17 °F) and amount: product pages, read live, identical to Hydro-Québec’s list of October 26, 2026. Hydro-Québec confirms the amount when you apply.

10 · Frequently asked questions

Your questions about the Airy.

Product-page figures are read live: when a product page changes, the answer follows. The others come from the dated documents at the foot of the page.

AirGreen × KINGHOMESold and installed by AirGreenAIRY R32Up to 30 SEER211.2 HSPF2Montreal · Laval · Longueuil · South Shore · North Shore

Sources checked on October 26, 2026

  1. AirGreen Kinghome Airy product pages (metafields), read live.
  2. Kinghome Canada, Airy submittals, 4 models (March 13, 2026), and Airy brochures (English of July 22, 2026, French of July 6, 2026), read Oct. 26, 2026; R32 Split Type outdoor unit manual (Dec. 4, 2025).
  3. NEEP, Cold Climate Air Source Heat Pump List, Kinghome wall unit records (modified Aug. 24 to Sept. 4, 2026), re-read Oct. 26, 2026.
  4. ENERGY STAR, certified heat pumps dataset w7cv-9xjt (Canadian market), re-read Oct. 26, 2026.
  5. Hydro-Québec, LogisVert list “owner, existing home” of Oct. 26, 2026; participation guide v1.10 (Sept. 15, 2026).
  6. Environment and Climate Change Canada, 1991-2020 climate normals, Montreal-Trudeau, re-read Oct. 26, 2026.
  7. Québec.ca, “Mesure du bruit” (updated June 16, 2022), re-read Oct. 26, 2026.

The amounts shown are estimates; only the responsible organizations confirm the assistance granted. Capacities and sound levels come from Kinghome documents and certificates; your installation may give a different result.