AirGreenKINGHOME
KINGHOME · R32 WALL HEAT PUMPSThe KINGHOME space at AirGreenSold and installed by AirGreen · Montreal, Laval, Longueuil, South Shore and North Shore
KINGHOME warranty
AirGreen × KINGHOMESold and installed by AirGreen22 R32 wall units9,000 to 36,000 BTU/h115 V in CHARMO and CLIVIAPre-charged for 7.5 m45 cm under the outdoor unitMontreal · Laval · Longueuil · South Shore · North Shore
02 · Your installation

One size, four series: what each one needs in your home.

Pick a size, then the voltage when a 115 V model exists: space on the wall, line, circuit and outdoor unit, side by side. “Not published” means Kinghome does not give the figure.

Size
Voltage

Dimensions, airflow, line sizes, MCA / MOP and sound: product pages, read live. Line, height difference and weight: 2026 Kinghome brochures, with the submittal as a note when it differs or when the brochure does not cover the model. Pre-charge and additional charge: R32 Split Type manual (Polaris: submittals). Height under the unit: submittals. Base-pan heater: NEEP.

AirGreen × KINGHOME

What KINGHOME requires at installation, what AirGreen brings.

KINGHOME sets its installation rules in its manual and submittals. AirGreen picks the wall unit with you and installs it.

KINGHOME

What KINGHOME sets out for installation

  • Pre-charged for 7.5 m of lineBeyond that, R-32 is added: 0.2 or 0.4 oz per foot depending on the model (manual).
  • 45 cm under the outdoor unitFor snow and defrost water, per the submittals of all four series.
  • A base-pan heater68 to 160 W depending on the model, on during defrost and below 1 °C (Polaris 24,000: below -5 °C), per NEEP.
  • “Leak test is a must”Vacuum to -0.1 MPa, then a mandatory leak test after installation (manual).
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free home estimateWe come to see the house and choose the series and size with you.
  • A clear quotationWith the indicative LogisVert amount of the chosen model.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.

The result: the right KINGHOME, chosen with you and installed by AirGreen.

The KINGHOME wall shop

All wall units, right below.

Filter by capacity or series, then open the product page: each one carries its AHRI number and, from 12,000 BTU/h, its indicative LogisVert amount.

KINGHOME
Everything to know

Everything to know before installing a Kinghome wall unit

Montreal cold, outdoor noise, wall space, room size and what the technician must follow. Everything comes from Kinghome Canada documents, NEEP, ENERGY STAR, Environment Canada and Québec.ca.

03 · Deep cold

At each published temperature, how much heat is left.

Pick a size and a temperature: the four series show the maximum heat published on NEEP, the COP and the minimum heat. Below their coldest published point, a series is marked out of range.

Size

The NEEP curve, from 8.3 to -30 °C

04 · Noise

A wall unit’s noise, inside and out, placed on the Québec.ca scale.

Pick a model: the indoor range and the outdoor unit sound from its product page appear on the Government of Québec scale. The sheets give no test conditions: compare models with each other.

Series
Model
20 dB(A)A whisper heard at one metre, a light wind in the trees
30 dB(A)A conversation in a low voice
40 dB(A)A library, a refrigerator, a quiet street at night
50 dB(A)Moderate rain, a washing machine
60 dB(A)A normal conversation
70 dB(A)A busy street, a vacuum cleaner

Scale: Québec.ca, “Mesure du bruit”, updated June 16, 2022. Levels: product pages (indoor minimum / maximum, outdoor). Polaris: its submittals (Sept. 17, 2026) give higher levels than its product page and brochure; the note shows under the model.

05 · On the wall

The four wall units of the same size, to scale.

The template draws each series’ indoor unit on a 1 ft grid: useful to see what fits above a window or between two frames.

Size

Dimensions: product pages (width × depth × height, inches). 1 ft grid. The outdoor units are in the table and in Your installation.

06 · Room size

What size for your room?

ENERGY STAR’s official table, with its four corrections. The result points to the smallest Kinghome size that covers it.

Sunlight
People in the room
07 · Technician’s corner

What the Kinghome documents require, in numbers.

The R32 Split Type outdoor unit manual covers Charmo, Clivia and Airy; Polaris has its own manual (Sept. 24, 2026), with the same installation rules. All four series have their submittals.

Above any surface

45 cm

The submittals of all four series want the outdoor unit at least 18 in (45 cm) above any surface, for snow and defrost water.

The manual’s minimum

3 / 20 cm

At least 3 cm under the unit for the drain joint, 20 cm for a model with a heating element. The support must carry 4 times the unit’s weight.

Pre-charge

7.5 m

The outdoor unit is pre-charged for 7.5 m (24.6 ft) of line. Beyond that, R-32 is added per the table.

Vacuum

-0.1 MPa

Vacuum pump 10 to 15 minutes, pressure must hold at -0.1 MPa, then 1 to 2 minutes with the pump closed. Then, “Leak test is a must after installation”.

Clearances

30 cm

At least 30 cm between the outdoor unit and the wall; 30, 50 and 200 cm to obstacles depending on the side (manual diagram).

Bending

10 cm

Minimum bending radius of 10 cm. If the outdoor unit is higher than the wall hole, a U-shaped loop keeps rain out.

Base-pan heater

68-160 W

Per NEEP, each of our Kinghome wall units listed on NEEP has one, on during defrost and below 1 °C (Polaris 24,000: below -5 °C).

Breaker (MOP)

15-30 A

The maximum breaker rating, from the product page; 20 A for the 115 V models. Details in the table below.

R-32 refrigerant

A2L

Global warming potential of 675 (SOR/2016-137). The manual treats it as an A2L, mildly flammable, with its own installation and service precautions.

Max. length / max. height difference (ft), 230 V

Series9,00012,00018,00024,00030,00036,000
Charmo66 / 4066 / 4082 / 33131 / 82131 / 82*131 / 82*
Clivia66 / 4066 / 40131 / 82131 / 82--
Airy100 / 60100 / 60131 / 82131 / 82--
Polaris131 / 82*131 / 82*131 / 82*131 / 82*--

2026 Kinghome brochures (July 22, 2026). *: submittals (Charmo 30,000 and 36,000, not in the brochure: July 16, 2026; Polaris height difference, which its brochure does not give: Sept. 17, 2026). The submittals allow more for Charmo and Clivia at 9,000 and 12,000 (100 / 60) and for Charmo 18,000 (131 / 82): we follow the brochure, which is more cautious.

Additional charge (oz/ft)

Series9,00012,00018,00024,00030,00036,000
Charmo0.20.20.20.20.40.4
Clivia0.20.20.20.4--
Airy0.20.20.40.4--
Polaris*0.20.20.20.4--

R32 Split Type manual, Dec. 4, 2025. *Polaris: brochure and submittals. The Charmo brochure prints 0.1 oz/ft for the 24,000 (the manual says 0.2); the Clivia 24,000 submittal says 0.2 (the manual and the brochure say 0.4).

Circuit: MCA / MOP (A)

Series9,00012,00018,00024,00030,00036,000
Charmo10 / 1512 / 1513 / 1515 / 2027 / 3024 / 30
Charmo 115 V19 / 2019 / 20----
Clivia10 / 1510 / 1516 / 2022 / 30--
Clivia 115 V19 / 2019 / 20----
Airy10 / 1510 / 1520 / 2525 / 30--
Polaris13 / 1513 / 1516 / 2022 / 30--

Product pages, read live. MCA: minimum circuit ampacity. MOP: maximum overcurrent protection.

Flare nut tightening torque

1/4 in15-20 N·m
3/8 in30-40 N·m
1/2 in45-55 N·m
5/8 in60-65 N·m
3/4 in70-75 N·m

R32 Split Type manual, p. 18; same values in the Polaris manual.

08 · Glossary

Eight words from product pages and quotes, explained on the back of the card.

09 · LogisVert

LogisVert in three numbers.

Each model’s amount, the calculation and the application deadline are on the Kinghome page. Here, what applies to the wall units.

10 · Frequently asked questions

Your questions about installing a Kinghome wall unit.

Product-page figures are read live: when a product page changes, the answer follows. The others come from the dated documents at the foot of the page.

AirGreen × KINGHOMESold and installed by AirGreenCHARMO · CLIVIA · AIRY · POLARISPre-charged for 7.5 m45 cm under the outdoor unitMontreal · Laval · Longueuil · South Shore · North Shore

Sources checked on October 26, 2026

  1. AirGreen Kinghome product pages (metafields), read live.
  2. NEEP, Cold Climate Air Source Heat Pump List, 21 Kinghome records (modified Aug. 24 to Sept. 4, 2026), re-read Oct. 26, 2026.
  3. ENERGY STAR, certified heat pumps dataset w7cv-9xjt (Canadian market), re-read Oct. 26, 2026.
  4. Hydro-Québec, LogisVert list “owner, existing home” of Oct. 26, 2026 (ENERGY STAR CSV depot read by Hydro-Québec’s tool); participation guide v1.10 (Sept. 15, 2026).
  5. Kinghome Canada, Charmo, Clivia, Airy and Polaris brochures (July 22, 2026, re-read Oct. 26, 2026); submittals of all four series (Charmo, Clivia, Airy: March 13 and July 16, 2026; Polaris: Sept. 17, 2026), read Oct. 26, 2026; outdoor unit manuals: R32 Split Type (Dec. 4, 2025, reissued Aug. 11, 2026), Airy (Aug. 14, 2026) and Polaris (Sept. 24, 2026).
  6. Environment and Climate Change Canada, 1991-2020 climate normals, Montreal-Trudeau (page modified Aug. 10, 2026), re-read Oct. 26, 2026.
  7. Québec.ca, “Mesure du bruit” (updated June 16, 2022), re-read Oct. 26, 2026.
  8. ENERGY STAR, Room Air Conditioners sizing table, re-read Oct. 26, 2026; Heat Pump criteria v6.2.
  9. SOR/2016-137, Schedule 1 (GWP of HFC-32).

The amounts shown are estimates; only the responsible organizations confirm the assistance granted. Capacities and sound levels come from Kinghome documents and certificates; your installation may give a different result.