Kinghome wall heat pumps: what it takes to install one in your home
22 R32 wall units in four series, from 9,000 to 36,000 BTU/h. To pick a series by what matters to you, the Kinghome page has its selector and comparison table. Here, we answer the installation questions: space on the wall, the line to the outdoor unit, the electrical circuit and the heat left when it is -25 °C.
Who makes which size?
All 22 formats at a glance. Each pill opens the product page.
| BTU/h | Charmo | Clivia | Airy | Polaris |
|---|---|---|---|---|
| 9,000 | 220 V115 V | 220 V115 V | 220 V | 220 V |
| 12,000 | 220 V115 V | 220 V115 V | 220 V | 220 V |
| 18,000 | 220 V | 220 V | 220 V | 220 V |
| 24,000 | 220 V | 220 V | 220 V | 220 V |
| 30,000 | 220 V | |||
| 36,000 | 220 V |
Nominal sizes and voltage: product pages, read live.
Four series, four installation sheets.
Each card sums up what matters for the installation: width on the wall, line allowed, breaker, outdoor sound and height under the outdoor unit. Choosing by priority is on the Kinghome page.

Charmo
9,000-36,000 BTU/hThe only one of our Kinghome wall series above 24,000 BTU/h. Also comes in 115 V.- Models8
- 115 Vyes
- Indoor width32.88-42.44 in
- Max. line (brochure)66-131 ft
- Breaker (MOP)15-30 A
- Outdoor sound51-62 dB(A)
- Min. height outside45 cm

Clivia
9,000-24,000 BTU/hOptional mini-ERV fresh-air kit, per Kinghome. Also comes in 115 V.- Models6
- 115 Vyes
- Indoor width32.95-39.09 in
- Max. line (brochure)66-131 ft
- Breaker (MOP)15-30 A
- Outdoor sound52-59 dB(A)
- Min. height outside45 cm

Airy
9,000-24,000 BTU/hLine up to 100 ft from the 9,000 up, per its brochure.- Models4
- 115 Vno
- Indoor width38.19-43.7 in
- Max. line (brochure)100-131 ft
- Breaker (MOP)15-30 A
- Outdoor sound55-62 dB(A)
- Min. height outside45 cm

Polaris
9,000-24,000 BTU/hLine up to 131 ft from the 9,000 up, per its brochure and submittals.- Models4
- 115 Vno
- Indoor width35.6-43.9 in
- Max. line (brochure)131 ft
- Breaker (MOP)15-30 A
- Outdoor sound55 dB(A)submittals: up to 60
- Min. height outside45 cm
Models, sizes, voltage, width, MOP and sound: product pages, read live. Line: 2026 Kinghome brochures (Charmo 30,000 and 36,000: submittals). 45 cm: submittals of all four series.
One size, four series: what each one needs in your home.
Pick a size, then the voltage when a 115 V model exists: space on the wall, line, circuit and outdoor unit, side by side. “Not published” means Kinghome does not give the figure.
Dimensions, airflow, line sizes, MCA / MOP and sound: product pages, read live. Line, height difference and weight: 2026 Kinghome brochures, with the submittal as a note when it differs or when the brochure does not cover the model. Pre-charge and additional charge: R32 Split Type manual (Polaris: submittals). Height under the unit: submittals. Base-pan heater: NEEP.
What KINGHOME requires at installation, what AirGreen brings.
KINGHOME sets its installation rules in its manual and submittals. AirGreen picks the wall unit with you and installs it.

What KINGHOME sets out for installation
- Pre-charged for 7.5 m of lineBeyond that, R-32 is added: 0.2 or 0.4 oz per foot depending on the model (manual).
- 45 cm under the outdoor unitFor snow and defrost water, per the submittals of all four series.
- A base-pan heater68 to 160 W depending on the model, on during defrost and below 1 °C (Polaris 24,000: below -5 °C), per NEEP.
- “Leak test is a must”Vacuum to -0.1 MPa, then a mandatory leak test after installation (manual).
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free home estimateWe come to see the house and choose the series and size with you.
- A clear quotationWith the indicative LogisVert amount of the chosen model.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: the right KINGHOME, chosen with you and installed by AirGreen.
All wall units, right below.
Filter by capacity or series, then open the product page: each one carries its AHRI number and, from 12,000 BTU/h, its indicative LogisVert amount.

Everything to know before installing a Kinghome wall unit
Montreal cold, outdoor noise, wall space, room size and what the technician must follow. Everything comes from Kinghome Canada documents, NEEP, ENERGY STAR, Environment Canada and Québec.ca.
At each published temperature, how much heat is left.
Pick a size and a temperature: the four series show the maximum heat published on NEEP, the COP and the minimum heat. Below their coldest published point, a series is marked out of range.
Environment and Climate Change Canada, 1991-2020 normals. Heating points: NEEP, only at the published temperatures, no interpolation.
The NEEP curve, from 8.3 to -30 °C
A wall unit’s noise, inside and out, placed on the Québec.ca scale.
Pick a model: the indoor range and the outdoor unit sound from its product page appear on the Government of Québec scale. The sheets give no test conditions: compare models with each other.
Scale: Québec.ca, “Mesure du bruit”, updated June 16, 2022. Levels: product pages (indoor minimum / maximum, outdoor). Polaris: its submittals (Sept. 17, 2026) give higher levels than its product page and brochure; the note shows under the model.
The four wall units of the same size, to scale.
The template draws each series’ indoor unit on a 1 ft grid: useful to see what fits above a window or between two frames.
Dimensions: product pages (width × depth × height, inches). 1 ft grid. The outdoor units are in the table and in Your installation.
What size for your room?
ENERGY STAR’s official table, with its four corrections. The result points to the smallest Kinghome size that covers it.
What the Kinghome documents require, in numbers.
The R32 Split Type outdoor unit manual covers Charmo, Clivia and Airy; Polaris has its own manual (Sept. 24, 2026), with the same installation rules. All four series have their submittals.
Above any surface
45 cmThe submittals of all four series want the outdoor unit at least 18 in (45 cm) above any surface, for snow and defrost water.
The manual’s minimum
3 / 20 cmAt least 3 cm under the unit for the drain joint, 20 cm for a model with a heating element. The support must carry 4 times the unit’s weight.
Pre-charge
7.5 mThe outdoor unit is pre-charged for 7.5 m (24.6 ft) of line. Beyond that, R-32 is added per the table.
Vacuum
-0.1 MPaVacuum pump 10 to 15 minutes, pressure must hold at -0.1 MPa, then 1 to 2 minutes with the pump closed. Then, “Leak test is a must after installation”.
Clearances
30 cmAt least 30 cm between the outdoor unit and the wall; 30, 50 and 200 cm to obstacles depending on the side (manual diagram).
Bending
10 cmMinimum bending radius of 10 cm. If the outdoor unit is higher than the wall hole, a U-shaped loop keeps rain out.
Base-pan heater
68-160 WPer NEEP, each of our Kinghome wall units listed on NEEP has one, on during defrost and below 1 °C (Polaris 24,000: below -5 °C).
Breaker (MOP)
15-30 AThe maximum breaker rating, from the product page; 20 A for the 115 V models. Details in the table below.
R-32 refrigerant
A2LGlobal warming potential of 675 (SOR/2016-137). The manual treats it as an A2L, mildly flammable, with its own installation and service precautions.
Max. length / max. height difference (ft), 230 V
| Series | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
|---|---|---|---|---|---|---|
| Charmo | 66 / 40 | 66 / 40 | 82 / 33 | 131 / 82 | 131 / 82* | 131 / 82* |
| Clivia | 66 / 40 | 66 / 40 | 131 / 82 | 131 / 82 | - | - |
| Airy | 100 / 60 | 100 / 60 | 131 / 82 | 131 / 82 | - | - |
| Polaris | 131 / 82* | 131 / 82* | 131 / 82* | 131 / 82* | - | - |
2026 Kinghome brochures (July 22, 2026). *: submittals (Charmo 30,000 and 36,000, not in the brochure: July 16, 2026; Polaris height difference, which its brochure does not give: Sept. 17, 2026). The submittals allow more for Charmo and Clivia at 9,000 and 12,000 (100 / 60) and for Charmo 18,000 (131 / 82): we follow the brochure, which is more cautious.
Additional charge (oz/ft)
| Series | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
|---|---|---|---|---|---|---|
| Charmo | 0.2 | 0.2 | 0.2 | 0.2 | 0.4 | 0.4 |
| Clivia | 0.2 | 0.2 | 0.2 | 0.4 | - | - |
| Airy | 0.2 | 0.2 | 0.4 | 0.4 | - | - |
| Polaris* | 0.2 | 0.2 | 0.2 | 0.4 | - | - |
R32 Split Type manual, Dec. 4, 2025. *Polaris: brochure and submittals. The Charmo brochure prints 0.1 oz/ft for the 24,000 (the manual says 0.2); the Clivia 24,000 submittal says 0.2 (the manual and the brochure say 0.4).
Circuit: MCA / MOP (A)
| Series | 9,000 | 12,000 | 18,000 | 24,000 | 30,000 | 36,000 |
|---|---|---|---|---|---|---|
| Charmo | 10 / 15 | 12 / 15 | 13 / 15 | 15 / 20 | 27 / 30 | 24 / 30 |
| Charmo 115 V | 19 / 20 | 19 / 20 | - | - | - | - |
| Clivia | 10 / 15 | 10 / 15 | 16 / 20 | 22 / 30 | - | - |
| Clivia 115 V | 19 / 20 | 19 / 20 | - | - | - | - |
| Airy | 10 / 15 | 10 / 15 | 20 / 25 | 25 / 30 | - | - |
| Polaris | 13 / 15 | 13 / 15 | 16 / 20 | 22 / 30 | - | - |
Product pages, read live. MCA: minimum circuit ampacity. MOP: maximum overcurrent protection.
Flare nut tightening torque
| 1/4 in | 15-20 N·m |
|---|---|
| 3/8 in | 30-40 N·m |
| 1/2 in | 45-55 N·m |
| 5/8 in | 60-65 N·m |
| 3/4 in | 70-75 N·m |
R32 Split Type manual, p. 18; same values in the Polaris manual.
Eight words from product pages and quotes, explained on the back of the card.
LogisVert in three numbers.
Each model’s amount, the calculation and the application deadline are on the Kinghome page. Here, what applies to the wall units.
Your questions about installing a Kinghome wall unit.
Product-page figures are read live: when a product page changes, the answer follows. The others come from the dated documents at the foot of the page.
No question matches. Call us at 514 316-2973.
We see the house, choose the size with you, and install.
We come to see the house and choose the series and size with you. The estimate is done at your home, with no commitment, and it is free.
Gas or oil: that work goes to a licensed partner.
Sources checked on October 26, 2026
- AirGreen Kinghome product pages (metafields), read live.
- NEEP, Cold Climate Air Source Heat Pump List, 21 Kinghome records (modified Aug. 24 to Sept. 4, 2026), re-read Oct. 26, 2026.
- ENERGY STAR, certified heat pumps dataset w7cv-9xjt (Canadian market), re-read Oct. 26, 2026.
- Hydro-Québec, LogisVert list “owner, existing home” of Oct. 26, 2026 (ENERGY STAR CSV depot read by Hydro-Québec’s tool); participation guide v1.10 (Sept. 15, 2026).
- Kinghome Canada, Charmo, Clivia, Airy and Polaris brochures (July 22, 2026, re-read Oct. 26, 2026); submittals of all four series (Charmo, Clivia, Airy: March 13 and July 16, 2026; Polaris: Sept. 17, 2026), read Oct. 26, 2026; outdoor unit manuals: R32 Split Type (Dec. 4, 2025, reissued Aug. 11, 2026), Airy (Aug. 14, 2026) and Polaris (Sept. 24, 2026).
- Environment and Climate Change Canada, 1991-2020 climate normals, Montreal-Trudeau (page modified Aug. 10, 2026), re-read Oct. 26, 2026.
- Québec.ca, “Mesure du bruit” (updated June 16, 2022), re-read Oct. 26, 2026.
- ENERGY STAR, Room Air Conditioners sizing table, re-read Oct. 26, 2026; Heat Pump criteria v6.2.
- SOR/2016-137, Schedule 1 (GWP of HFC-32).
The amounts shown are estimates; only the responsible organizations confirm the assistance granted. Capacities and sound levels come from Kinghome documents and certificates; your installation may give a different result.