THERMO 2000 BTH Ultra 15 Electric Boiler | 15 kW - 240V
The Thermo 2000 BTH ULTRA 15: a 15 kW, 240 V wall-mounted electric boiler with two 3 kW elements and two 4.5 kW elements.
Model numberBTH ULTCA 15
514 316-2973 · sales@airgreen.ca
Quick facts
15 kW on the wall to heat the home or take over from your heat pump
A wall-mounted boiler that plays two roles
Thermo 2000’s BTH ULTRA 15 can be the main heat source of a home heated with hot water, or the backup for a heat pump, a geothermal system or solar collectors. Either way, it delivers 15 kW at 240 V, or 51,180 BTU/h, in a 63 lb wall-mounted cabinet that holds 2 US gallons of water.
This size suits a bungalow heated by radiators, a single-storey home with radiant floors in the basement, or a homeowner who has installed an air-to-water heat pump and wants reliable backup for January nights. It also easily replaces a wall-mounted electric boiler at the end of its life.
What sets it apart
The BTH ULTRA 15 combines two 3 kW elements and two 4.5 kW elements, spread over four stages. The T2 UltraSmart controller modulates output based on the loop’s demand and sets the water temperature from the supplied outdoor sensor, on one of three curves (MIN, STD, MAX). The backlit display shows the settings, and presets by distribution system make commissioning easier, whether for radiant floors, baseboards or radiators.
When the boiler serves as backup, these settings come into their own. Warm weather shutdown keeps it at rest during periods when the heat pump is enough, and Boost mode is there for more demanding mornings. Pump purge and a 24 V supply for the thermostat and accessories round out the controller.
What to plan electrically
At 240 V single phase, the boiler draws 62.5 A and Thermo 2000 lists an 80 A breaker. The wire gauge is confirmed with the installation manual. If your building is supplied at 208 V, Thermo 2000 states that output is multiplied by 0.75: we take this into account when choosing the size.
What AirGreen’s installation covers
We start with a free on-site estimate: heating loop, main source if any, electrical panel and wall space. You receive a written quote describing the chosen size and each step. Our technicians then install the boiler, connect it to the loop through its 1 in NPT connections and to the electrical circuit, fill and purge the system, then set the controller to work with your heat pump or on its own.
AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.
Next step
We serve Montreal, Laval, Longueuil, the South Shore and the North Shore.
Book your free estimate and get a written quote for your BTH ULTRA 15; financing is available.
A wall-mounted boiler to heat the home or back up a heat pump
The BTH ULTRA 15 heats radiant floors, radiators or hot water baseboards. Thermo 2000 also designs it as backup for a heat pump, geothermal or solar system, in new construction as well as replacement.
- Backup for an air-to-water heat pump feeding a radiant floor
- Bungalow or single-storey home heated by hot water radiators
- Replacing an existing wall-mounted electric boiler
- Backup for a geothermal or solar system
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- 240 V single-phase, 60 Hz power supply: 62.5 A, on an 80 A breaker. Wire gauge is confirmed with Thermo 2000’s installation manual.
- At 208 V, output is multiplied by 0.75 and current by 0.867, according to Thermo 2000.
- 63 lb wall-mounted boiler, 1 in female NPT water connections (two reducers supplied).
- Maximum working pressure of 30 psi (207 kPa), with the 30 psi relief valve supplied.
- 30 psi relief valve
- Drain valve
- 2 reducers
- Outdoor sensor
- Temperature and pressure gauge
Manufacturer documents
Explore the range
Electric boilersSee allSame brand
THERMO 2000See all
Frequently asked questions
Why two element sizes?
The BTH ULTRA 15 combines two 3 kW elements and two 4.5 kW elements to reach 15 kW over four stages. The T2 UltraSmart controller modulates output based on the loop’s demand.
Can it back up an air-to-water heat pump?
Yes. Thermo 2000 presents the BTH ULTRA as backup for a heat pump, a geothermal system or a solar system. We set the boiler so it supplements your main source.
Which breaker does it need?
An 80 A breaker on a 240 V single-phase circuit; the unit draws 62.5 A. We confirm the wire gauge with the installation manual and check your panel during the free estimate.
What comes with the boiler?
The 30 psi relief valve, drain valve, two reducers, outdoor sensor and temperature and pressure gauge.
How hot does it heat the water?
The operating range is 50 °F to 190 °F (10 °C to 90 °C). An automatic limit at 208 °F and a manual limit at 227 °F protect the unit.
A 15 kW BTH ULTRA, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.