Élios Heating Element for EAHM Air Handler

In stock

The original heater kit for the Central-Elios EAHM multi-position air handler, from 5 to 25 kW.

AirGreen codeAG-AC-01202

5 to 25 kW6 nominal ratings
1 or 2 stagesdepending on rating
208-230 Vsingle phase, 60 Hz
Central heat pumpGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-01202
BrandÉlios
Part no.EAH05EUL to EAH25EUL
ForÉlios EAHMA24 to EAHMA60 multi-position air handlers
Power208-230 V, 1 ph, 60 Hz
ComponentsRelay, circuit breaker

The Élios EAHxxEUL series heating element is the electric backup heat for the Central-Elios EAHM multi-position air handler. It covers six nominal outputs, from 5 to 25 kW, at 208-230 V single-phase. According to the manufacturer's drawing, each element carries its own relay and breaker.

The electric complement to the central heat pump

With an EAHM air handler, the central heat pump heats the house through the existing ducts. The element takes over when the heat pump needs extra heat, which makes it a common solution for replacing an electric furnace. The 5, 8 and 10 kW elements heat in one stage; the 15, 20 and 25 kW elements, in two stages.

Outputs listed by air handler size

  • 5 kW: EAHMA24, 30 and 36.
  • 8 kW: EAHMA24 to 48.
  • 10 and 15 kW: EAHMA24 to 60.
  • 20 kW: EAHMA36 to 60.
  • 25 kW: EAHMA60 only.

Circuits and power supply

The 5, 8 and 10 kW elements connect to a single circuit. The 15 and 20 kW require two and the 25 kW, three, each with its own MCA and maximum overcurrent protection value. At 230 V, the 25 kW draws 100 A in total for 23 kW actual. The values for each size are shown in the table when you select it. Have the capacity of your electrical service confirmed before choosing a high output.

Installed by AirGreen in Greater Montréal

We install the element in your Élios air handler and set up the backup heat with the heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore; the supply circuit is done by a master electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the air handler model, the output and the quantity.

01 · What it is for

Backup heat for the Élios central heat pump

In an EAHM air handler, the kit tops up the central heat pump and can heat on its own when needed.

  • Backup heat for a Central-Elios heat pump with an EAHM air handler
  • All-electric homes with no furnace
  • Replacing an electric furnace with an air handler and a heat pump
  • Replacing an EUL-series heater
Six ratings5 to 25 kW nominal, each listed by Élios for specific air handler sizes.
Two stages from 15 kWThe 15, 20 and 25 kW kits heat in two stages; 5, 8 and 10 kW in one.
Relay and breakerThe manufacturer’s drawing shows a relay and a circuit breaker on every EUL kit.
Compatible with
EAHMA24R4AS1EAHMA30R4AS1EAHMA36R4AS1EAHMA48R4AS1EAHMA60R4AS1
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

6 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelStages / circuitsActual output at 208 / 230 VTotal current at 208 / 230 VTotal MCA at 208 / 230 VTotal MOCP at 208 / 230 VNet weightCompatible air handlersPart no.AirGreen code
5 kW – EAH05EUL1 / 13.75 / 4.6 kW18 / 20 A23 / 27 A25 / 30 A2.6 kg (5.7 lb)EAHMA24, EAHMA30, EAHMA36EAH05EULAG-AC-01201
8 kW – EAH08EUL1 / 16 / 7.35 kW28.8 / 32 A37 / 42 A40 / 45 A3.3 kg (7.3 lb)EAHMA24, EAHMA30, EAHMA36, EAHMA48EAH08EULAG-AC-01202
10 kW – EAH10EUL1 / 17.5 / 9.2 kW36.1 / 40 A46 / 53 A50 / 60 A3.1 kg (6.8 lb)EAHMA24, EAHMA30, EAHMA36, EAHMA48, EAHMA60EAH10EULAG-AC-01203
15 kW – EAH15EUL2 / 211.25 / 13.8 kW54.1 / 60 A69 / 80 A75 / 90 A4 kg (8.8 lb)EAHMA24, EAHMA30, EAHMA36, EAHMA48, EAHMA60EAH15EULAG-AC-01204
20 kW – EAH20EUL2 / 215 / 18.4 kW72.1 / 80 A92 / 106 A100 / 120 A4.4 kg (9.7 lb)EAHMA36, EAHMA48, EAHMA60EAH20EULAG-AC-01205
25 kW – EAH25EUL2 / 318.75 / 23 kW90.1 / 100 A115 / 133 A125 / 150 A5.7 kg (12.6 lb)EAHMA60EAH25EULAG-AC-01206

Nominal output. Actual values, circuits and compatible air handlers are in the table for the size you pick.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandÉlios
TypeElectric heater kit (backup heat)
SeriesEAHxxEUL
ModelsEAH05EUL, EAH08EUL, EAH10EUL, EAH15EUL, EAH20EUL, EAH25EUL
Power208-230 V, 1 ph, 60 Hz
Heating stages1 (5 to 10 kW), 2 (15 to 25 kW)
ComponentsRelay, circuit breaker
Net dimensions (W × D × H)8 × 21.13 × 10.13 in; 8 × 21.13 × 11.75 in for 25 kW
Air handlersÉlios EAHMA24R4AS1, EAHMA30R4AS1, EAHMA36R4AS1, EAHMA48R4AS1, EAHMA60R4AS1
Stages / circuits1 / 1
Actual output at 208 / 230 V6 / 7.35 kW
Total current at 208 / 230 V28.8 / 32 A
Total MCA at 208 / 230 V37 / 42 A
Total MOCP at 208 / 230 V40 / 45 A
Net weight3.3 kg (7.3 lb)
Compatible air handlersEAHMA24, EAHMA30, EAHMA36, EAHMA48
Part no.EAH08EUL
AirGreen codeAG-AC-01202
04 · Before installing

What to know before installing

  • Each rating is listed for certain air handler sizes only: check the table for the size you pick.
  • The 15 and 20 kW kits have 2 supply circuits and the 25 kW has 3, each with its own protection.
  • The 25 kW kit needs up to 133 A total MCA at 230 V: your electrical service must handle it.
  • The supply circuit is done by a licensed electrician, with the unit powered off.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which kit fits my EAHM air handler?

Per the Élios submittals: 5 kW for the EAHMA24 to 36, 8 kW up to the 48, 10 and 15 kW for every size from 24 to 60, 20 kW for 36 to 60 and 25 kW for the 60 only. We pick the rating from a heating load calculation.

How many circuits do I need?

One for the 5, 8 and 10 kW kits, two for the 15 and 20 kW and three for the 25 kW, per the manufacturer’s sheet. Each circuit has its own MCA and max. overcurrent protection.

Can I use a 24 V thermostat?

Élios lists its ST1S42RW1 smart thermostat and its wired controllers for the EAHM. The MI3C1 mini interface also lets you connect a standard 24 V thermostat, with some functions possibly reduced.

Can you install it?

Yes. We fit the kit in the air handler and set up the backup heat with the heat pump; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Original backup heat for your Élios EAHM air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.