LG

LG Electric Heater Element for Air Handler Cabinet

In stock

The genuine LG electric heat kit that adds backup heat to the multi-position air handler of your LG central heat pump.

AirGreen codeAG-AC-01402

5 to 20 kWfour sizes
208/230 Vsingle phase, 60 Hz
Breakerbuilt into the kit
R-32Multi-position air handlerGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-01402
BrandLG
Part nos.ANEH053C1, ANEH103C2, ANEH153C3, ANEH203C3
ForLG multi-position air handlers
Power208/230 V, 60 Hz, 1 phase
ControlHarness plugs into the air handler board

The LG ANEH electric element is the OEM backup heat for LG multi-position air handler cabinets. It installs in the central heat pump cabinet and its control harness plugs into the cabinet’s board: the LG unit turns it on when the heat pump can no longer keep up, during a defrost or for emergency heat.

Electric backup designed for extreme cold

In Québec, a central heat pump loses capacity as the outdoor temperature drops. The element closes the gap without changing equipment. LG offers it in 5, 10, 15 and 20 kW at 230 V (4.1, 8.2, 12.3 and 16.4 kW at 208 V), 208/230 V single-phase. LG shows it with its bracket, its built-in breaker and a bimetal relay.

The right element for your cabinet

  • ANEH053C1 (5 kW): 12,000 to 60,000 BTU/h cabinets, one circuit, 30 A breaker.
  • ANEH103C2 (10 kW): from 18,000 BTU/h, one circuit, 60 A breaker.
  • ANEH153C3 (15 kW): from 36,000 BTU/h, two circuits (60 A and 30 A).
  • ANEH203C3 (20 kW): from 42,000 BTU/h, two circuits (60 A and 60 A).

Compatible cabinets and points to check

LG lists them for the KNSLBxxxA and KNSLAxxxA single-zone cabinets, Multi F / Multi F MAX KNMLBxxxA and Multi V ZRNUxxxNAAA, NBAA and NCAA. The element needs a separate power supply. If a third-party thermostat is connected through a dry contact, it cannot control the backup heat. Wiring follows the LG manual and the electrical code.

Installed by AirGreen across Greater Montréal

Our technicians install the element in your LG cabinet and coordinate the wiring with a master electrician in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with your cabinet model and the output you need.

01 · What it is for

Backup heat inside the heat pump air handler

The kit slides into the LG air handler and steps in when the heat pump needs help in deep cold.

  • Backup heat for an LG central heat pump with a multi-position air handler
  • Single-zone (KNSLBxxxA, KNSLAxxxA) and Multi F / Multi F MAX (KNMLBxxxA) air handlers
  • Multi V air handlers (ZRNUxxxNAAA, ZRNUxxxNBAA, ZRNUxxxNCAA)
  • Emergency heat during defrost or an outdoor unit failure
Controlled by the air handlerThe control harness plugs into the air handler board, so the LG unit decides when the heater runs.
Built-in breakerLG shows the kit with its bracket, circuit breaker and bi-metal relay.
Sized to the cabinetLG publishes a compatibility grid: the bigger the air handler, the larger the heater it accepts.
Compatible with
KNSLBxxxAKNSLAxxxAKNMLBxxxAZRNUxxxNAAAZRNUxxxNBAAZRNUxxxNCAA
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

4 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelPart no.Output (208 / 230 V)Heater current (208 / 230 V)Power circuitsCircuit breakerAllowed air handlersAirGreen code
5 kW – ANEH053C1ANEH053C14.1 / 5 kW19.7 / 21.7 A130 A12,000 to 60,000 Btu/hAG-AC-01401
10 kW – ANEH103C2ANEH103C28.2 / 10 kW39.4 / 43.5 A160 A18,000 to 60,000 Btu/hAG-AC-01402
15 kW – ANEH153C3ANEH153C312.3 / 15 kWCircuit 1: 39.4 / 43.5 A; circuit 2: 19.7 / 21.7 A260 A + 30 A36,000 to 60,000 Btu/hAG-AC-01403
20 kW – ANEH203C3ANEH203C316.4 / 20 kW39.4 / 43.5 A per circuit260 A + 60 A42,000 to 60,000 Btu/hAG-AC-01404

Output at 208 V / 230 V. The air handler size limits the heater you can use.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandLG
TypeAuxiliary electric heat kit for multi-position air handler
ModelsANEH053C1, ANEH103C2, ANEH153C3, ANEH203C3
Power supply208/230 V, 60 Hz, 1 phase
ControlHarness connects to the air handler control board
ComponentsBracket, circuit breaker, bi-metal relay
Compatible air handlersKNSLBxxxA, KNSLAxxxA, KNMLBxxxA, ZRNUxxxNAAA, ZRNUxxxNBAA, ZRNUxxxNCAA
Part no.ANEH103C2
Output (208 / 230 V)8.2 / 10 kW
Heater current (208 / 230 V)39.4 / 43.5 A
Power circuits1
Circuit breaker60 A
Allowed air handlers18,000 to 60,000 Btu/h
AirGreen codeAG-AC-01402
04 · Before installing

What to know before installing

  • Check the air handler size: 5 kW fits every size, 10 kW from 18,000 Btu/h, 15 kW from 36,000 Btu/h, 20 kW from 42,000 Btu/h.
  • The heater needs its own power supply, separate from the air handler.
  • The 15 and 20 kW kits have two power circuits.
  • With a third-party thermostat on a dry contact, supplemental heat cannot be controlled by that thermostat.
  • The electrical connection is a job for a licensed electrician.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which heater fits my LG air handler?

Per LG’s grid: 5 kW on every air handler from 12,000 to 60,000 Btu/h, 10 kW from 18,000 Btu/h, 15 kW from 36,000 Btu/h and 20 kW from 42,000 Btu/h. Send us the air handler model number (KNSL…, KNML… or ZRNU…) and we confirm before ordering.

Why two ratings, 208 V and 230 V?

Real output drops with voltage. A 10 kW kit at 230 V delivers 8.2 kW at 208 V, per LG’s sheet.

Do I need a breaker at the panel?

Yes. The kit has a built-in breaker, but it needs a separate supply protected at the panel, sized per LG’s sheet and the code.

Can you install it?

Yes. We fit the kit in the air handler and connect it with a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Add backup heat to your LG air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.