Arcoaire Electric Heater Kit for FVM4X and FCM4X Fan Coils

In stock

Genuine electric backup heat for Arcoaire FVM4X and FCM4X fan coils, from 5 to 30 kW.

AirGreen codeAG-AC-13506

5 to 30 kWsix kits
208/230 Vpower supply
FVM4X, FCM4XArcoaire fan coils
Fan coilGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-13506
BrandArcoaire
Part no.EHK05AKB to EHK30AHCF
ForFVM4X and FCM4X fan coils
Power supply208/230 V

Arcoaire EHK electric heater kits install in Arcoaire FVM4X variable-speed and FCM4X Observer communicating fan coils. They provide backup heat for a central heat pump by warming the air already moving through the ductwork. This page groups six kits, from 5 to 30 kW.

Six outputs for FVM4X and FCM4X fan coils

For each kit, Arcoaire publishes the fan coil sizes that accept it and its electrical values at 208 and 230 V. The 5 and 10 kW kits are protected by built-in circuit breakers; the 15 to 30 kW kits by fuses. Part number EHK25AHCF is a 24 kW kit.

The kits and their fan coils

  • EHK05AKB (5 kW), EHK10AKB (10 kW), EHK15AKF (15 kW) and EHK20AKF (20 kW): every size, from 2400 to 6000
  • EHK25AHCF (24 kW) and EHK30AHCF (30 kW): sizes 4800 and 6000 only

One or several circuits

The 5 and 10 kW kits connect to a single circuit. The 15 and 20 kW kits are fed by one circuit or two; for single-point wiring, Arcoaire lists the EBAC01SPK kit, sold separately. The 24 and 30 kW kits ship as 3-phase and convert to single phase, with one circuit or three. Arcoaire also states that the 15 and 20 kW kits are not recommended for some heat pump applications: the fan coil airflow is checked before choosing. Have your electrical service checked before choosing a high output.

Installed by AirGreen in Greater Montréal

We install the kit in your Arcoaire fan coil and set up the backup heat with the heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore; the supply circuit is done by a licensed electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the fan coil model, the output and the quantity.

01 · What it is for

Backup heat for the Arcoaire fan coil

Installed in the fan coil, the kit warms the air already moving through the ducts when the heat pump needs extra heat.

  • Backup heat for a central heat pump with an FVM4X or FCM4X fan coil
  • Homes heated electrically through ductwork
  • Replacing an EHK kit on an existing fan coil
  • Large 4800 and 6000 sizes, paired with the 24 and 30 kW kits
Six outputsFrom 5 to 30 kW, each listed by Arcoaire for specific fan coil sizes.
Breakers or fusesThe 5 and 10 kW kits have built-in circuit breakers; the 15 to 30 kW kits, fuses.
One or several circuitsThe 15 and 20 kW kits take one or two circuits; the 24 and 30 kW, up to three in single phase.
Compatible with
FVM4X2400BFVM4X3600BFVM4X4800BFVM4X6000BFCM4X2400FCM4X3600FCM4X4800FCM4X6000
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

6 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelOutputPower supplyBuilt-in protectionSupply circuitsHeater current at 208 / 230 VMCA at 208 / 230 V (1 circuit)Max. protection (MOCP) at 208 / 230 V (1 circuit)Fan coils listed by ArcoairePart no.AirGreen code
5 kW – EHK05AKB5 kWSingle phase, 208/230 VCircuit breakers118.1 / 20.0 A26.0 / 28.4 A (sizes 2400 and 3600); 31.2 / 33.5 A (sizes 4800 and 6000)30 / 30 A (sizes 2400 and 3600); 35 / 35 A (sizes 4800 and 6000)FVM4X2400B, FVM4X3600B, FVM4X4800B, FVM4X6000B; FCM4X2400, FCM4X3600, FCM4X4800, FCM4X6000EHK05AKBAG-AC-13501
10 kW – EHK10AKB10 kWSingle phase, 208/230 VCircuit breakers136.2 / 40.0 A53.8 / 58.5 A60 / 60 AFVM4X2400B, FVM4X3600B, FVM4X4800B, FVM4X6000B; FCM4X2400, FCM4X3600, FCM4X4800, FCM4X6000EHK10AKBAG-AC-13502
15 kW – EHK15AKF15 kWSingle phase, 208/230 VFuses1 or 254.2 / 59.9 A76.3 / 83.4 A80 / 90 AFVM4X2400B, FVM4X3600B, FVM4X4800B, FVM4X6000B; FCM4X2400, FCM4X3600, FCM4X4800, FCM4X6000EHK15AKFAG-AC-13503
20 kW – EHK20AKF20 kWSingle phase, 208/230 VFuses1 or 272.3 / 79.9 A98.9 / 108.4 A100 / 110 AFVM4X2400B, FVM4X3600B, FVM4X4800B, FVM4X6000B; FCM4X2400, FCM4X3600, FCM4X4800, FCM4X6000EHK20AKFAG-AC-13504
24 kW – EHK25AHCF24 kWShipped 3-phase, convertible to single phase, 208/230 VFuses1 in 3-phase; 1 or 3 in single phase86.7 / 95.5 A (single phase); 50.1 / 55.4 A (3-phase)116.9 / 127.9 A (single phase); 71.2 / 77.8 A (3-phase)125 / 150 A (single phase); 80 / 80 A (3-phase)FVM4X4800B, FVM4X6000B; FCM4X4800, FCM4X6000EHK25AHCFAG-AC-13505
30 kW – EHK30AHCF30 kWShipped 3-phase, convertible to single phase, 208/230 VFuses1 in 3-phase; 1 or 3 in single phase109.0 / 120.0 A (single phase); 62.6 / 69.2 A (3-phase)144.8 / 158.5 A (single phase); 86.8 / 95.0 A (3-phase)150 / 175 A (single phase); 90 / 100 A (3-phase)FVM4X4800B, FVM4X6000B; FCM4X4800, FCM4X6000EHK30AHCFAG-AC-13506

Per Arcoaire, the MCA and maximum protection values include the motor of the largest fan coil used with the kit.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandArcoaire
TypeElectric heater kit for fan coil
Outputs5, 10, 15, 20, 24 and 30 kW
Power supply208/230 V; EHK25AHCF and EHK30AHCF ship 3-phase, convertible to single phase
Built-in protectionCircuit breakers (EHK05AKB, EHK10AKB), fuses (EHK15AKF, EHK20AKF, EHK25AHCF, EHK30AHCF)
Fan coilsArcoaire FVM4X and FCM4X, sizes 2400 to 6000 (24 and 30 kW: 4800 and 6000)
Single-point wiringEBAC01SPK kit for the 15 and 20 kW fused kits, sold separately
Output30 kW
Power supplyShipped 3-phase, convertible to single phase, 208/230 V
Built-in protectionFuses
Supply circuits1 in 3-phase; 1 or 3 in single phase
Heater current at 208 / 230 V109.0 / 120.0 A (single phase); 62.6 / 69.2 A (3-phase)
MCA at 208 / 230 V (1 circuit)144.8 / 158.5 A (single phase); 86.8 / 95.0 A (3-phase)
Max. protection (MOCP) at 208 / 230 V (1 circuit)150 / 175 A (single phase); 90 / 100 A (3-phase)
Fan coils listed by ArcoaireFVM4X4800B, FVM4X6000B; FCM4X4800, FCM4X6000
Part no.EHK30AHCF
AirGreen codeAG-AC-13506
04 · Before installing

What to know before installing

  • The 24 and 30 kW kits are listed for sizes 4800 and 6000 only.
  • Arcoaire states the 15 and 20 kW kits are not recommended for some heat pump applications: the fan coil airflow must be checked.
  • EHK25AHCF and EHK30AHCF ship as 3-phase; they are converted to single phase on site.
  • The manufacturer requires copper wire; the circuit is sized from the nameplate and the Québec electrical code.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which kit fits my fan coil?

Per Arcoaire, the 5 to 20 kW kits fit every FVM4X and FCM4X size from 2400 to 6000; the 24 and 30 kW kits fit sizes 4800 and 6000 only. We pick the output from a heating load calculation.

Why is EHK25AHCF a 24 kW kit?

That is the output Arcoaire publishes for this part number. It ships as 3-phase and converts to single phase, with one circuit or three.

Do I need a single-point wiring kit?

For the 15 and 20 kW fused kits, Arcoaire lists the EBAC01SPK single-point wiring kit, sold separately.

Can you install it?

Yes. We fit the kit in the fan coil and set up the backup heat with the heat pump; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Genuine backup heat for your Arcoaire fan coil