GENERAL AIRSTAGE Long Life Filter for Medium Static Pressure Ducted Unit
The genuine long-life filter for AIRSTAGE medium static pressure ducted units (GENERAL or Fujitsu), in three sizes by capacity.
AirGreen codeAG-AC-00501
514 316-2973 · sales@airgreen.ca
Quick facts
For its medium static pressure ducted units, namely the R-32 ARUH…KUAS models and the previous ARU…RGLX generation, the manufacturer offers a filtration option: the GENERAL AIRSTAGE long life filter, in UTD-LFNA, UTD-LFNB or UTD-LFNC versions. With the GENERAL name on the packaging, it remains identical to the one sold under the Fujitsu AIRSTAGE brand, since Fujitsu General Limited, now under Paloma Rheem Holdings, has operated as GENERAL Inc. since January 1, 2026. Placed upstream, it catches dust before it makes its way to the coil and the fan.
One size for each capacity group
Concealed in a ceiling or an attic, the ducted unit pushes air into ducts that serve several rooms at once. That whole zone therefore relies on a single filter. The units’ submittal sheets show that the manufacturer ties each size to a specific capacity group.
Which filter for which unit
- UTD-LFNC: ARUH12KUAS and ARU12RGLX, the 12,000 BTU group
- UTD-LFNB: ARUH18KUAS, ARUH24KUAS and ARUH30KUAS, a group running from 18,000 to 30,000 BTU
- UTD-LFNA: ARUH36KUAS, ARUH42KUAS and ARUH48KUAS, a group running from 36,000 to 48,000 BTU
Keeping the filter in good shape
As it gets dirty, the filter holds back the airflow, which costs the heat pump both comfort and efficiency. Plan a check at least at every change of season, always after cutting power to the unit. If your ducted unit hides in a corner that is tough to get to, the filter check can be part of our annual maintenance.
Your ducted units, maintained by AirGreen
AirGreen installs and maintains AIRSTAGE ducted units, GENERAL or Fujitsu, from Montreal to Laval and Longueuil, and out to the North Shore and the South Shore, under its RBQ licence 5645-9605-01. Have the indoor unit model number and the number of filters you need at hand, then contact us at 514 316-2973 or sales@airgreen.ca for availability or a quote.
The filter made for your ducted unit
The manufacturer offers this filter as an option for its medium static ducted units, with one size per capacity group.
- AIRSTAGE (GENERAL or Fujitsu) ARUH12KUAS to ARUH48KUAS ducted units (R-32)
- ARU12RGLX to ARU48RGLX ducted units
- Replacing a worn GENERAL or Fujitsu long-life filter
- Adding the optional filter at installation
3 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Modèle | Unit capacity | Units listed by the manufacturer | Part no. | AirGreen code |
|---|---|---|---|---|
| UTD-LFNA – 36 000 à 48 000 BTU | 36,000, 42,000 and 48,000 BTU | ARUH36KUAS, ARUH42KUAS, ARUH48KUAS, ARU36RGLX, ARU42RGLX, ARU48RGLX | UTD-LFNA | AG-AC-00501 |
| UTD-LFNB – 18 000 à 30 000 BTU | 18,000, 24,000 and 30,000 BTU | ARUH18KUAS, ARUH24KUAS, ARUH30KUAS, ARU18RGLX, ARU24RGLX, ARU30RGLX | UTD-LFNB | AG-AC-00502 |
| UTD-LFNC – 12 000 BTU | 12,000 BTU | ARUH12KUAS, ARU12RGLX | UTD-LFNC | AG-AC-00503 |
Pick the size by the indoor unit’s capacity, shown in its model number (ARUH24KUAS = 24,000 BTU).
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Read the indoor unit model number: the size depends on its capacity.
- Switch off the unit before reaching the filter.
- A clogged filter cuts airflow: check it every season.
- Follow the unit’s installation manual for the filter location.
You may also need
GENERAL AIRSTAGE IR Receiver Kit with Wireless Remote Control (Ducted and Air Handler) – UTY-LBTUM
GENERAL AIRSTAGE Remote Temperature Sensor – UTY-XSZXZ1
GENERAL AIRSTAGE KAGAMI Wired Controller – UTY-RVRU
GENERAL AIRSTAGE UTY-TFSXJ4 Wi-Fi Module for Non-Wall-Mounted Unit (UART)
Fujitsu Leak Detection System Accessory – UTYSGZU
GENERAL AIRSTAGE Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)Original partsSee all
Frequently asked questions
Which filter for my ducted unit?
The manufacturer lists UTD-LFNC for 12,000 BTU units, UTD-LFNB for 18, 24 and 30,000 BTU and UTD-LFNA for 36, 42 and 48,000 BTU. The number after ARUH or ARU in the model number is the capacity.
Does it fit a slim duct unit?
The manufacturer lists it for its medium static ducted units (ARUH and ARU…RGLX). For another type of unit, send us the model number.
How often should I check it?
At least every change of season, more often during renovations or with pets.
Can you install it?
Yes. We fit it when installing or servicing your ducted unit, everywhere in Greater Montréal.
A genuine filter for your GENERAL or Fujitsu AIRSTAGE ducted unit
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.