GOODMAN CHPTA1822B3 Evaporator A-Coil | 1.5 Tons

In stock

The Goodman CHPTA1822B3 1.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCHPTA1822B3

1.5 tons18,000 BTU/h nominal
22 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCHPTA1822B3
ManufacturerGoodman
Size1.5 tons
Width22 in
RefrigerantR-32
MeteringTXV

Goodman CHPTA1822B3 coil: 1.5 ton, 22 in wide and a cabinet 17-1/2 in high

A plex owner in Laval once asked us this question: "My ground-floor unit is small, my furnace is narrow, but my basement is fairly high. Do I really have to take the smallest coil possible?" The short answer is no. When height is not a problem, the Goodman CHPTA1822B3 evaporator coil is often the most logical choice for a 1.5 ton system.

It is the same size as the CHPTA1822A3, with the same width, the same R-32 and the same TXV. What sets it apart is a taller cabinet: 22 × 17-1/2 × 21 in. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Why two coils for the same capacity?

Two 1.5 ton models exist in the range because furnaces do not all have the same free volume above the heat exchanger. The A3 is the shorter of the two; the B3 rises to 17-1/2 in. The second leaves a longer air path above the cabinet, which can make the transition to the supply plenum easier and leave the coil less cramped to reach later, at the time of maintenance.

In practice, if your plenum is already tall and clear, the B3 fits in without moving anything. If the ceiling is right overhead, the A3 has the advantage. We take measurements before deciding, and the decision is made on site.

How the coil works

Mounted on the furnace, it receives liquid refrigerant from the outdoor unit through the 3/8 in line. The fluid expands in the TXV, evaporates in the fins and returns outside through the 3/4 in suction line. Along the way, the air in the house, pushed by the blower, is cooled and loses some of its moisture. The water collected in the pan flows to the drain.

With a heat pump upstream, the same path is used for heating: the heat captured outdoors is given up to the air circulating in your existing ducts.

CHPTA1822B3 spec sheet

  • type: cased A-coil evaporator, CHPTA range;
  • nominal size: 1.5 ton (18,000 BTU/h);
  • refrigerant: R-32;
  • dimensions W × H × D: 22 × 17-1/2 × 21 in;
  • liquid connection: 3/8 in; suction connection: 3/4 in;
  • metering device: TXV;
  • published position: horizontal;
  • R-32 leak sensor designed to last the life of the coil;
  • 10-year limited parts warranty; online registration within 60 days of installation, not required in Quebec.

A detail that matters in summer: the pan and the drain

In a small home, condensation water is easy to forget until the day it overflows. The pan under the coil collects the water, then the drain carries it to a floor drain or a pump. We inspect the whole path: drain slope, access for cleaning and clearance around the cabinet. A taller cabinet like the B3's leaves a little more room for a hand during this annual check.

Think about the filter too. A clean filter spares the blower and protects the coil fins from dust. We show you where it is and how to replace it, so that basic upkeep becomes part of your routine.

A system well sized for a small volume

In a compact home, the temptation is to inflate the capacity "just in case". But an oversized system reaches the setpoint quickly, shuts off, then restarts: it never runs long enough to dry the air. You get cold without comfort. So we run the load calculation before recommending a size, taking into account insulation, windows and sun exposure.

What the match changes

This coil pairs with a Goodman outdoor unit of the same capacity and the same refrigerant. The two parts are installed together. No efficiency rating is attached to the coil alone: SEER2, EER2 and HSPF2 relate to the complete system, identified by an AHRI number. We verify it before the order so that the advertised ratings are the ones you will actually get.

A useful note: as of 2026-11-26, no R-32 match with this coil appears in the ENERGY STAR data set. The outdoor unit chosen is therefore validated in the AHRI directory.

B3 or another model? A short guide

  • You are weighing it against the CHPTA1822A3: same capacity and same width, but a shorter cabinet. Choose it only if height is tight;
  • Your furnace is 26 in wide: look at the CHPTA2426B3 or the CHPTA2426C3, which cover 1.5 to 2 tons;
  • Your needs exceed 2 tons: the CHPTA3026B3 and CHPTA3026C3 cover 2 to 2.5 tons, then the series climbs to 4 to 5 tons with the CHPTA6030D3;
  • All models use R-32 and the TXV: the choice therefore comes down to capacity, width and height.

And what happens to my furnace?

It stays. Its blower pushes the air, its filters clean it, and it serves as backup heat during the coldest weather when the outdoor unit is a heat pump. We set with you the temperature below which it takes over. We only need to confirm that the blower can reach the airflow the system calls for.

What our installation includes

AirGreen, a family-owned heating and cooling company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. At your home, we do the following:

  • measure the furnace and check the electrical panel;
  • install the cabinet and, if needed, a custom-built insulated transition;
  • install the outdoor unit on a stand, run brazed copper piping, and do the nitrogen test and vacuum;
  • connect the condensate drain and the thermostat;
  • start up the system, balance the airflow and show you how to use it.

Points to confirm before signing

  • R-32 requires a match with an outdoor unit using the same refrigerant.
  • The published ratings apply to the certified system.
  • The 22 in width and the furnace blower must be suitable.

The manufacturer behind the coil

Goodman belongs to Daikin Comfort Technologies, as do Daikin and Amana. The brand's R-32 range goes with new-generation central air conditioners and heat pumps, on a furnace or on a modular blower.

Financial assistance

Hydro-Québec programs assess the complete system according to the installation date, not the coil taken alone. We consult the official list when we prepare your quote and explain clearly what applies.

Take the next step

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CHPTA1822B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCHPTA1822B3
TypeCased evaporator coil
LineCHPTA
Nominal size1.5 tons (18,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D22 × 17-1/2 × 21 in
Model numberCHPTA1822B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 22 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.