GOODMAN CHPTA4830C3 Evaporator A-Coil | 3.5 to 4 Tons
The Goodman CHPTA4830C3 3.5 to 4-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCHPTA4830C3
514 316-2973 · sales@airgreen.ca
Quick facts
Goodman CHPTA4830C3: 3.5 to 4 tons for large homes, with a checklist to follow in order
When a home calls for 3.5 to 4 tons of cooling, the temptation is to look at the coil first. Our experience says the opposite: the coil comes last. Before it, four things have to be validated. The Goodman CHPTA4830C3 evaporator coil (48,000 BTU/h nominal, 30 in wide, 21 in high cabinet, R-32) then takes its logical place in a well-prepared project.
We carry out these projects in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, mostly in large homes, properties with finished basements and residences enlarged over the years.
Priority number one: the load calculation
At this size, an error of half a ton is costly, in either direction. We calculate the load room by room: glazed areas, insulation, exposure, volumes. If the result exceeds this coil's range, we propose the CHPTA6030D3. If it falls lower, the CHPTA4230C3 becomes a serious option.
Priority number two: the electrical entrance
The matched outdoor unit needs its own circuit. In a large home, the panel is sometimes already well occupied: dryer, stove, water heater, charging station. We examine the panel at the first visit and honestly tell you whether an upgrade is required. Our electrical work is done under our own licence.
Priority number three: the air network
A coil of this capacity demands a lot of air. If the ducts are too small or the returns insufficient, the system does not deliver what it promises. We inspect the network and the blower, and determine whether the airflow is up to the task. This point often decides the success of a large project.
Priority number four: the height above the furnace
The CHPTA4830C3 footprint is 30 × 21 × 21 in. This cabinet must find its place in the plenum, with enough clearance. We measure before the order, which avoids surprises on installation day.
And finally, the coil
- model: CHPTA4830C3, cased evaporator coil, CHPTA range, A-coil;
- nominal size: 3.5 to 4 tons (48,000 BTU/h);
- refrigerant: R-32, TXV metering device;
- dimensions W × H × D: 30 × 21 × 21 in;
- connections: 3/8 in liquid, 7/8 in suction;
- position published by the manufacturer: horizontal;
- R-32 refrigerant sensor designed to last the life of the coil;
- 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).
What a system this size changes in daily life
In a large home, air takes time to circulate from one end to the other. The system must therefore work for long periods, at moderate speed, to avoid differences between rooms. Good vent balancing, a well-placed thermostat and a clean filter count as much as the coil itself.
Humidity is the other issue. A finished basement, an open kitchen, several bathrooms: in summer, the air holds a lot of water. A correctly sized coil removes it continuously, and the pan directs it to the drain. We check that this drain has the right slope and clearance, because it must carry away a significant flow of water.
Positioning yourself in the series
The CHPTA4830C3 sits on the second-to-last step:
- below it, the CHPTA4230C3 (2.5 to 3.5 tons) and the CHPTA3630B3 and CHPTA3630C3 (2.5 to 3 tons) share its 30 in width;
- above it, the CHPTA6030D3 (4 to 5 tons) offers the largest capacity in the series;
- narrower and smaller: the CHPTA3026B3 and CHPTA3026C3 (2 to 2.5 tons, 26 in), the CHPTA2426B3 and CHPTA2426C3 (1.5 to 2 tons, 26 in), then the CHPTA1822A3 and CHPTA1822B3 (1.5 ton, 22 in).
All share R-32 and the TXV. Here, the only 3.5 to 4 ton model is this C3: there is no variant with a shorter cabinet.
One large system or two smaller ones?
In some large homes, two more modest systems, one per floor or zone, give better comfort than a single big unit. In others, a single system is simpler and less costly. We discuss this option without bias, because we want your installation to be well suited, not just to carry a big number.
The certified match
The CHPTA4830C3 pairs with a Goodman outdoor unit of the same capacity and the same refrigerant. The SEER2, EER2 and HSPF2 ratings belong to the system and are tied to an AHRI number; the coil has no rating of its own. As of 2026-11-26, we found no R-32 match with this coil in the ENERGY STAR data; we therefore confirm the number in the AHRI directory before committing to the order.
Planning the job
A project of this size is prepared. We set a date with you, plan access to the basement and to the yard for the outdoor unit, protect the floors and announce power shutoffs in advance. The goal is for installation day to run without improvisation, from the first connection to the final walk-through.
Backup heat and heat pump
With a heat pump, the furnace stays useful: it takes over when the outdoor temperature falls below the threshold that we program with you. In mild weather, the heat pump provides two to three times more heat than the electricity it consumes.
Our installation
AirGreen is a family-owned heating and cooling company established in Montreal for more than fifteen years, under RBQ licence 5645-9605-01 (refrigeration, ventilation, electrical). We provide:
- measuring the furnace, and checking the blower and the electrical panel;
- installing the cabinet in the plenum, the insulated transition if needed, sealing the duct joints;
- the outdoor unit on a base or stand, brazed piping, nitrogen test and vacuum;
- the condensate drain and the thermostat;
- commissioning, airflow adjustment, the explanation at your home.
Reminder of the points to confirm
- R-32: the outdoor unit uses the same refrigerant and is installed at the same time.
- The published ratings apply to the certified match.
- A 30 in wide furnace and a blower with the required airflow.
The brand
Goodman is part of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 coils install on a furnace or on a modular blower.
Incentives
Eligibility for Hydro-Québec programs depends on the complete system, according to the installation date. We consult the official list at the time of the quote and tell you what applies.
Get your estimate
Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CHPTA4830C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 30 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5 to 4-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.