GOODMAN CHPTA3026C3 Evaporator A-Coil | 2 to 2.5 Tons
The Goodman CHPTA3026C3 2 to 2.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCHPTA3026C3
514 316-2973 · sales@airgreen.ca
Quick facts
Replacing an old central air conditioner: the Goodman CHPTA3026C3, 2 to 2.5 tons, 21 in cabinet
Many of our customers are not starting from zero. They already have a central air conditioner that has had its day: a tired compressor, a clogged coil, a refrigerant from a bygone generation. They want to replace it without redoing their ductwork. The Goodman CHPTA3026C3 evaporator coil was designed for this scenario: 2 to 2.5 tons (30,000 BTU/h), 26 in wide, 21 in high, using R-32 refrigerant.
Here is how such a replacement goes with us, in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
First visit: we look, we measure, we listen
We come to your home to look at what is there. Which furnace? What plenum width? Where does the drain run? Does the electrical panel have room for the outdoor unit's circuit? We measure the top of the furnace because this coil, with its 21 in height and its 26 in width, needs a bit of vertical space. If that space is missing, we will propose the CHPTA3026B3 instead, with the same capacity and a shorter cabinet.
We also run the load calculation. It is what says whether 2 tons or 2.5 tons suits your home, not the age or size of the old unit. An old air conditioner was sometimes too big, sometimes too small: copying it without checking would only repeat the mistake.
Second step: the written quote
You receive a clear document: the coil, the matched outdoor unit, the AHRI number of the pair, what is included in the installation, what is not. We also indicate whether the Hydro-Québec program list may apply, depending on the installation date.
The coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings belong to the matched system, hence the importance of the AHRI number. As of 2026-11-26, no R-32 match with this model was listed in the ENERGY STAR data consulted.
Third step: the installation
The cabinet goes on the furnace, with an insulated transition built on site if the width does not match 26 in. The outdoor unit is set on its base, the piping is brazed, and the circuit is pressure-tested with nitrogen and pulled into a vacuum. Finally the drain and the thermostat are connected, then we start up and adjust the airflow.
What a new coil corrects
- a clean heat exchanger, without the crushed fins or the fouling of an old model;
- R-32 refrigerant and a leak sensor designed to last the life of the coil;
- a TXV metering device, which regulates the refrigerant flow in the heat exchanger;
- an insulated cabinet, which limits condensation on the walls.
CHPTA3026C3 spec sheet
- type: cased evaporator coil, CHPTA range;
- nominal size: 2 to 2.5 tons (30,000 BTU/h);
- dimensions W × H × D: 26 × 21 × 21 in;
- connections: 3/8 in for liquid and 7/8 in for suction;
- published installation position: horizontal;
- 10-year limited parts warranty; online registration within 60 days of installation, not required in Quebec.
Can the old outdoor unit be reused?
No, as a general rule. An R-32 coil pairs with an outdoor unit of the same refrigerant and the same capacity, installed at the same time. Hooking a new coil to an old compressor is not a saving: you lose the certified match and the ratings that go with it.
What you will feel after the replacement
The most visible difference is not always the temperature. It is the humidity. A system with a clean coil and well-chosen capacity removes water from the air while it cools: the sheets no longer stick, the basement stops smelling stale and the wooden door no longer swells in August. The house feels cool at a higher setpoint, which leaves room to save.
The second change is sound. A system that runs for a long time at moderate speed is less noticeable than an old model that starts abruptly, then shuts off, then starts again. People often tell us they only notice the system when they come home and feel how pleasant it is.
Frequently asked questions about replacement
Do the ducts have to be redone? Generally not. We inspect the existing network and point out any sections to fix before installation.
Will my electrical panel be enough? We check it at the first visit, because the outdoor unit needs its own circuit.
What if my furnace has a width other than 26 in? We build an insulated transition on site.
Where this model sits in the series
- CHPTA3026B3: same range, width and metering device; shorter cabinet;
- CHPTA2426B3 and CHPTA2426C3: same width, range of 1.5 to 2 tons;
- CHPTA3630B3 and CHPTA3630C3: 2.5 to 3 tons on 30 in, for wider furnaces;
- CHPTA1822A3 and CHPTA1822B3: 1.5 ton on 22 in;
- CHPTA4230C3, CHPTA4830C3 and CHPTA6030D3: from 2.5 up to 5 tons, on 30 in.
What becomes of the furnace
It stays right there. If you choose a heat pump, the coil will also heat in winter and the furnace will take over only below the temperature threshold programmed with you. With an air conditioner, it keeps its usual heating role. In every case, the blower must be able to provide the system's airflow, a point we check from the first visit.
Why replace now rather than wait for a breakdown
A breakdown almost always comes at the worst time: the first heat wave, when every installer is swamped. Replacing the system in spring or fall leaves time to compare, plan and check the incentive programs without pressure. We far prefer installing a well-chosen system to making an emergency repair.
About AirGreen
A family-owned heating and cooling company established in Montreal for more than fifteen years, AirGreen carries out its refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01.
To check before replacing
- R-32 requires an outdoor unit with the same refrigerant.
- The ratings apply to the certified match.
- The furnace width, the plenum height and the blower must be suitable.
The Goodman brand
Goodman is part of Daikin Comfort Technologies, like Daikin and Amana. Its R-32 coils install on a furnace or on a modular blower.
Incentives
Hydro-Québec programs cover the complete system. We validate the match against the official list at the time of the quote, according to the installation date, then tell you what applies in your case.
Plan your replacement
Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CHPTA3026C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 26 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2 to 2.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.