GOODMAN CHPTA3630B3 Evaporator A-Coil | 2.5 to 3 Tons

In stock

The Goodman CHPTA3630B3 2.5 to 3-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCHPTA3630B3

2.5 to 3 tons36,000 BTU/h nominal
30 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCHPTA3630B3
ManufacturerGoodman
Size2.5 to 3 tons
Width30 in
RefrigerantR-32
MeteringTXV

CHPTA3630B3: the 2.5 to 3 ton Goodman coil for the two-storey home and the large bungalow

The two-storey home with a basement furnace is probably the most common house in Greater Montreal. You find it in Laval, in Longueuil, in Boisbriand, in Brossard: ducts running up to the second floor, a living room open to the kitchen, bedrooms at the back that heat up in summer. For this kind of home, the Goodman CHPTA3630B3 evaporator coil is a natural candidate: 2.5 to 3 tons (36,000 BTU/h), 30 in wide, a cabinet 17-1/2 in high, R-32.

We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Identity card

  • model CHPTA3630B3, cased A-coil, CHPTA range;
  • 2.5 to 3 tons, or 36,000 BTU/h nominal;
  • R-32 refrigerant, TXV metering device;
  • dimensions W × H × D: 30 × 17-1/2 × 21 in;
  • 3/8 in liquid connection, 7/8 in suction;
  • published position: horizontal;
  • R-32 leak sensor designed to last the life of the coil;
  • 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).

Air matters as much as refrigerant

People talk a lot about tons and efficiency ratings. They talk less about what really makes a system succeed: the amount of air that passes through the coil. If the blower pushes too little, the coil frosts up; if the ducts are pinched, the faraway rooms stay hot. At 30 in wide, this model offers a large face to the air, but it cannot make up for a poorly designed duct network.

That is why, before proposing this size, we check the blower and look at the ducts: sections, elbows, air returns. If a fix is worthwhile, we price it transparently in the quote.

A concrete scenario

Take a two-storey home whose basement furnace is 30 in wide. In summer, the upper floor becomes stifling by late afternoon, despite an old central air conditioner running non-stop. During the visit, we find that the upstairs air return is undersized and that the filter is in poor condition. The load calculation gives a value within the 2.5 to 3 ton range.

The solution comes down to three things: a new coil and its matched outdoor unit, a corrected air return, and a replaced filter that is explained to you. The following summer, the upper floor is no longer an oven and the system no longer runs continuously: it works in long, quiet cycles.

What makes a coil freeze up

A coil that becomes covered in ice usually lacks air: a clogged filter, a slowing blower, vents closed in too many rooms. It can also lack refrigerant, but that is rarer with a new system that has been properly evacuated. In both cases, the ice blocks the airflow even more, and the problem gets worse. We adjust the airflow at start-up and show you the simple steps that prevent this scenario.

Common myths about capacity

  • "More tons, more comfort." False. An oversized unit shuts off before it has dried the air.
  • "My old system was three tons, so I want three." Not necessarily. The old system may have been poorly chosen, or your home may have been insulated since.
  • "The coil alone determines efficiency." No. The SEER2, EER2 and HSPF2 ratings belong to the certified system, identified by an AHRI number.

The certified match

The CHPTA3630B3 connects to a Goodman outdoor unit of the same capacity and the same refrigerant. We look up the pair's AHRI number in the directory before ordering, so that the ratings we quote are the ones your installation will get. As of 2026-11-26, the ENERGY STAR data set contained no R-32 match with this coil.

B3 or C3: the height decision

Its twin, the CHPTA3630C3, offers the same range, the same width and the same R-32, with a taller cabinet. The B3 is the right choice when the space above the furnace is limited. When height is plentiful, the C3 leaves a more generous air path. We decide with the tape measure in hand, after opening the plenum and looking at what is around it.

Finding your way around the series

  • If your furnace is 26 in: CHPTA3026B3 or CHPTA3026C3 (2 to 2.5 tons), unless your load is clearly larger;
  • If you need a bit more capacity on 30 in: CHPTA4230C3, from 2.5 to 3.5 tons;
  • If the home is large: CHPTA4830C3 (3.5 to 4 tons) or CHPTA6030D3 (4 to 5 tons);
  • If the home is small: the CHPTA1822A3, CHPTA1822B3, CHPTA2426B3 and CHPTA2426C3.

Heat pump or air conditioner?

With a central air conditioner, the coil cools in summer. With a heat pump, it also heats in winter, through the same ducts. The furnace stays in place: it keeps its blower, its filters and its role as backup for the coldest days, below a threshold that we program with you. A heat pump, remember, moves heat instead of producing it: in mild weather, it delivers two to three times more heat than the electricity it consumes.

Installation: what is included

AirGreen, a family-owned heating and cooling company established in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our installation includes:

  • measuring the furnace, and checking the blower and the electrical panel;
  • installing the cabinet in the plenum, with an insulated transition if needed, and sealing the duct joints;
  • placing the outdoor unit, brazed piping, nitrogen test and vacuum;
  • connecting the condensate drain and the thermostat;
  • start-up, airflow adjustment and the walk-through.

Before you decide

  • R-32 requires installing an outdoor unit with the same refrigerant, at the same time.
  • The published ratings apply to the certified match.
  • 30 in width and a suitable blower: we confirm this on site.

On Goodman

Goodman is a brand of Daikin Comfort Technologies, which also includes Daikin and Amana. Its R-32 coils equip the new heat pumps and central air conditioners, on a furnace or a modular blower.

Financial assistance

Hydro-Québec looks at the complete system, not the coil alone. We consult the official list at the time of the quote, according to the installation date, and tell you what applies.

Request a quote

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CHPTA3630B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCHPTA3630B3
TypeCased evaporator coil
LineCHPTA
Nominal size2.5 to 3 tons (36,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D30 × 17-1/2 × 21 in
Model numberCHPTA3630B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 30 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5 to 3-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.