GOODMAN CHPTA2426B3 Evaporator A-Coil | 1.5 to 2 Tons

In stock

The Goodman CHPTA2426B3 1.5 to 2-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCHPTA2426B3

1.5 to 2 tons24,000 BTU/h nominal
26 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCHPTA2426B3
ManufacturerGoodman
Size1.5 to 2 tons
Width26 in
RefrigerantR-32
MeteringTXV

CHPTA2426B3: the 1.5 to 2 ton Goodman coil for homes in the grey zone between small and medium

Some homes fall exactly between two sizes in the calculations. Not small enough for 1.5 ton, not big enough for 2.5 tons. A renovated bungalow on the South Shore with new windows, a Montreal duplex with a well-insulated upper floor, a semi-detached home in Laval with a half-finished basement: these are the typical customers for the Goodman CHPTA2426B3 evaporator coil.

It is a cased A-coil using R-32, with a nominal range covering 1.5 to 2 tons (24,000 BTU/h) on a width of 26 in. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Why a range and not a single figure

The "1.5 to 2 tons" label means this coil can be paired with outdoor units of different capacity within that span. It is your home's load calculation that determines the choice, not a rough rule based on floor area. Two homes of the same size can have very different needs depending on their insulation, windows and orientation.

We recommend the outdoor unit that fits the calculated load, then we confirm the match with the coil in the AHRI directory, which assigns a number to each certified combination.

What the 26 in width tells you

The dimensions are 26 × 17-1/2 × 21 in. The jump from 22 in to 26 in of width compared with the 1.5 ton models is no small detail: it follows the furnace and the airflow that passes through the coil. More fin surface exposes the air to more refrigerant, which sets the stage for the added capacity.

If your furnace has a different width, we measure and build an insulated transition on site. It is a routine job for us.

The numbers to know

  • model: CHPTA2426B3, cased coil, CHPTA range;
  • nominal range: 1.5 to 2 tons, or 24,000 BTU/h;
  • refrigerant: R-32;
  • metering device: TXV;
  • connections: 3/8 in for liquid and 7/8 in for suction;
  • published installation position: horizontal;
  • R-32 refrigerant sensor designed to last the life of the coil;
  • 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).

The suction line is larger than on the 22 in models: it goes with a higher refrigerant flow.

A simple test: is your home a candidate?

Answer these questions honestly, then compare with our calculation during the visit:

  • In summer, does the heat build up mostly upstairs or in a south-facing room?
  • Is your current furnace close to 26 in wide?
  • Were you offered a small 1.5 ton system, but you worry it will run out of steam on heat wave days?
  • Does a 2.5 ton system seem oversized for your floor area?

If you answer yes to two or three of these questions, this coil deserves serious consideration.

B3 or C3: the cabinet question

The CHPTA2426C3 shares the capacity, the 26 in width, the R-32 and the TXV. It has a taller cabinet. Our rule is simple: if the space above the furnace is limited, the B3 is preferable; if there is height, the C3 offers a roomier air path. We decide nothing before checking the plenum.

The neighbours in the series at a glance

  • CHPTA1822A3 and CHPTA1822B3: 1.5 ton, 22 in wide; for narrower furnaces and small homes;
  • CHPTA3026B3 and CHPTA3026C3: 2 to 2.5 tons, still 26 in wide. Same footprint as this one, more capacity;
  • CHPTA3630B3, CHPTA3630C3 and CHPTA4230C3: from 2.5 tons to 3.5 tons, on a 30 in width;
  • CHPTA4830C3 and CHPTA6030D3: from 3.5 tons to 5 tons, also on 30 in.

What you will notice day to day

A well-matched coil is easy to forget, and that is the whole point. In July, the air comes out of the grilles cooler and noticeably drier, the clammy feeling disappears from room to room and the thermostat stops calling for short cycles. In winter, with a heat pump, the heat arrives milder and steadier than from a furnace that fires up hard and then shuts off.

Noise is also a good measure: a system whose capacity is well chosen runs at a moderate speed most of the time. An oversized system, on the other hand, shows itself through repeated starts that you can hear throughout the house.

The match and the efficiency ratings

The coil pairs with a Goodman outdoor unit of the same capacity and the same refrigerant, installed at the same time. It carries no efficiency rating of its own: SEER2, EER2 and HSPF2 belong to the certified system. To compare two quotes, always ask for the AHRI number. As of 2026-11-26, no R-32 match with this coil is listed with ENERGY STAR in the data set we consulted.

What a heat pump does that electricity alone does not

A baseboard heater or an electric furnace converts each unit of electricity into one unit of heat. A heat pump instead moves the heat present outdoors to the inside: in mild weather, it delivers two to three times the energy it consumes. When it is very cold, this ratio drops, and the furnace takes over at the threshold we program with you.

How the installation goes

AirGreen is a family-owned heating and cooling company established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. The job includes:

  1. measuring the furnace and plenum, then checking the blower and the electrical entrance;
  2. installing the cabinet, with a transition built if needed, and sealing the joints;
  3. installing the outdoor unit, brazed piping, nitrogen test and vacuum;
  4. connecting the condensate drain and the thermostat;
  5. commissioning, airflow adjustment and a full explanation of how it works.

To confirm before ordering

  • R-32 refrigerant: the outdoor unit must be of the same type.
  • The published ratings correspond to the certified match.
  • The furnace must offer the 26 in width and a blower capable of the airflow required.

Goodman in two lines

The brand is a division of Daikin Comfort Technologies, which also owns Daikin and Amana. Its R-32 coils install on a furnace or on a modular blower.

Incentives

Hydro-Québec programs apply to the complete system. We check the official list against the installation date and tell you what applies before you sign.

Get your quote

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CHPTA2426B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCHPTA2426B3
TypeCased evaporator coil
LineCHPTA
Nominal size1.5 to 2 tons (24,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D26 × 17-1/2 × 21 in
Model numberCHPTA2426B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 26 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 1.5 to 2-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.