The Goodman CHPTA3026B3 2 to 2.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCHPTA3026B3

2 to 2.5 tons30,000 BTU/h nominal
26 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCHPTA3026B3
ManufacturerGoodman
Size2 to 2.5 tons
Width26 in
RefrigerantR-32
MeteringTXV

Questions and answers about the Goodman CHPTA3026B3 coil, 2 to 2.5 tons in a 26 in cabinet

The Goodman CHPTA3026B3 evaporator coil is mostly of interest to owners of bungalows, compact cottages and semi-detached homes that have a mid-width furnace but a more serious cooling load than average. Rather than a dry spec sheet, here are the questions that customers in Montreal, Laval, Longueuil, on the North Shore and on the South Shore ask us most often about it.

What exactly is this product?

A cased A-coil from the CHPTA range, using R-32 refrigerant. It sits in the furnace plenum and receives refrigerant from the outdoor unit. Its nominal range runs from 2 to 2.5 tons, or 30,000 BTU/h, and it measures 26 × 17-1/2 × 21 in. The metering device is a TXV.

Why 26 in of width for a capacity of 2 to 2.5 tons?

That is the particularity of this model. For the same 26 in width, the series offers two ranges: 1.5 to 2 tons with the CHPTA2426B3, 2 to 2.5 tons here. The footprint is identical, which means a 26 in furnace can take either one. Only the load calculation will say which one fits.

Also, the suction line is 7/8 in on both, and the liquid line 3/8 in. The difference therefore lies in the exchange surface and in the planned match with the outdoor unit, not in the size.

How many tons does my home need?

No reliable rule fits in one line. Living area, ceiling height, insulation quality, window size and orientation, a finished basement, all of it shifts the result. We run the load calculation on site. If the figure falls in the 2 to 2.5 ton zone, this coil comes into play.

And what if a unit that is too big were proposed? The system would start short-cycling, cool the air without time to remove the humidity, and leave the house sticky. That is why we prefer a right-sized system to a generous one.

Does it heat too?

Only with a heat pump as the outdoor unit. In that case, the coil delivers heat to the air in your home in winter, and the same appliance serves both seasons. With a central air conditioner, it only provides cooling. The furnace stays in place, with its blower, its filters and its role as relay in very cold weather, below a threshold that we program with you.

Can we keep the old air conditioner?

Generally, no. The CHPTA3026B3 runs on R-32 and must pair with the outdoor unit specified by the manufacturer, of the same capacity. So we install the complete system, coil and unit together. We also confirm the match's AHRI number in the directory before the order, because the SEER2, EER2 and HSPF2 ratings belong to the system, not to the coil alone.

As of 2026-11-26, no R-32 match with this coil was listed in the ENERGY STAR data set; AHRI serves as the reference.

B3 or C3?

The CHPTA3026C3 has the same capacity, the same width and the same R-32, but a taller cabinet. If your mechanical room is low, the B3 is the one to pick. If the plenum has room, the C3 is possible. In both cases, we measure before answering.

Does a finished basement change the choice?

Often, yes. A finished basement adds volume to cool and, sometimes, rooms whose air vents are far from the furnace. In that case, capacity alone is not enough: the duct network also has to let enough air through. We look at the existing ducts, spot the pinched sections and tell you frankly whether a fix is needed before installation.

Conversely, a home whose upper floor gets very hot in summer, but whose ground floor stays cool, responds well to a carefully sized system and good airflow balancing. The coil is only one link: it is the whole system that delivers comfort.

And compared with the other sizes?

  • Smaller, same width: CHPTA2426B3 and CHPTA2426C3, from 1.5 to 2 tons;
  • Smaller and narrower: CHPTA1822A3 and CHPTA1822B3, at 1.5 ton, on 22 in;
  • Larger and wider: CHPTA3630B3 and CHPTA3630C3, from 2.5 to 3 tons, on 30 in, then CHPTA4230C3, from 2.5 to 3.5 tons;
  • The large sizes: CHPTA4830C3 (3.5 to 4 tons) and CHPTA6030D3 (4 to 5 tons).

Full spec sheet

  • model: CHPTA3026B3;
  • type: cased evaporator coil;
  • nominal size: 2 to 2.5 tons (30,000 BTU/h);
  • refrigerant: R-32;
  • dimensions W × H × D: 26 × 17-1/2 × 21 in;
  • connections: 3/8 in liquid, 7/8 in suction;
  • metering device: TXV;
  • position: horizontal;
  • R-32 refrigerant sensor designed to last the life of the coil;
  • 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).

How long does it take to get used to?

Not long. After start-up, the thermostat replaces the window air conditioners and the extra fans. The rooms even out, the air is drier, and you stop wondering which bedroom will be bearable at nightfall. For winter, a heat pump changes the dynamic of the bill: it moves heat rather than making it, which gives, in mild weather, two to three times more heat than the electricity consumed.

Our installation, step by step

AirGreen is a family-owned heating and cooling company in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. On this project, we:

  1. take the furnace measurements and check the blower and the electrical panel;
  2. install the cabinet in the plenum, with an insulated transition if the width differs, and seal the joints;
  3. install the outdoor unit, braze the piping, test the circuit with nitrogen and pull a vacuum;
  4. connect the drain and the thermostat;
  5. start the system, adjust the airflow and explain how it works.

Three checks before buying

  • R-32 requires an outdoor unit with the same refrigerant, installed at the same time.
  • The published ratings belong to the certified match.
  • The furnace must have the right width and a blower with the required airflow.

A word about Goodman

The brand belongs to Daikin Comfort Technologies, which also produces Daikin and Amana. Its R-32 coils equip recent central air conditioners and heat pumps, on a furnace or on a modular blower.

And the incentives?

Eligibility for Hydro-Québec programs concerns the complete system, according to the installation date, and not the coil by itself. We consult the official list while preparing your quote and tell you what applies.

Next step

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CHPTA3026B3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCHPTA3026B3
TypeCased evaporator coil
LineCHPTA
Nominal size2 to 2.5 tons (30,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D26 × 17-1/2 × 21 in
Model numberCHPTA3026B3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 26 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2 to 2.5-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.