GOODMAN CHPTA3630C3 Evaporator A-Coil | 2.5 to 3 Tons

In stock

The Goodman CHPTA3630C3 2.5 to 3-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberCHPTA3630C3

2.5 to 3 tons36,000 BTU/h nominal
30 inwidth
R-32refrigerant
R-32Add-on heat pumpCasedR-32
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberCHPTA3630C3
ManufacturerGoodman
Size2.5 to 3 tons
Width30 in
RefrigerantR-32
MeteringTXV

A year with the Goodman CHPTA3630C3: 2.5 to 3 tons, 30 in wide, 21 in cabinet

A coil is judged over twelve months, not on a spec sheet. Here, season by season, is what the Goodman CHPTA3630C3 evaporator coil does in a home in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, once it is installed on the furnace and matched with a Goodman outdoor unit of the same capacity.

Spring: the start-up

This is the best time to install. Schedules are more flexible, temperatures let us shut off the heat without discomfort, and you have time to compare. We measure the furnace, check the electrical panel, then install the 30 × 21 × 21 in cabinet (width, height, depth). This 21 in height calls for a clear plenum; if space is too tight, the CHPTA3630B3, with the same range but a shorter cabinet, settles the question.

The outdoor unit is set, the piping is brazed, and the circuit is pressure-tested with nitrogen and then pulled into a vacuum. The drain and the thermostat are connected. We start up, adjust the airflow and explain how it works.

Summer: the coil at work

R-32 refrigerant flows through the tubes, passes through the TXV and evaporates in the fins. The air in the house, pushed by the blower, gives up its heat and its humidity. The water runs into the pan and then to the drain. Upstairs, the air is cool; in the basement, it is dry.

The 2.5 to 3 ton size (36,000 BTU/h) suits homes big enough to justify a generous central system, without sliding into oversizing. An oversized system short-cycles and leaves the humidity in place: so we size it as closely as possible, based on your home's actual load.

Fall: inspection time

Before the cold, we clean. A glance at the filter, a check of the drain, an inspection of the pan. If your outdoor unit is a heat pump, we check that nothing is blocking its fins (leaves, branches). This routine is simple and extends the life of the system.

It is also the time when we set with you the outdoor temperature threshold below which the furnace will take over from the heat pump. This setting determines the split between electric or backup heat and the heat coming from the heat pump.

Winter: if the outdoor unit is a heat pump

The cycle reverses: the refrigerant captures heat outdoors, even in cold weather, and delivers it to the air in the house through the coil. A heat pump moves heat rather than making it; at mild temperatures, it provides two to three times more heat than the electricity it consumes, and this ratio declines as the cold deepens. In the coldest weather, the furnace takes over, with its blower and its filters.

Five questions to ask any installer

  1. What is the AHRI number of the proposed match, and can it be checked in the directory?
  2. Has the load calculation for my home been done, or was the capacity guessed?
  3. Who checks the blower airflow and the condition of the ducts?
  4. Is the circuit pressure-tested with nitrogen and pulled into a vacuum before start-up?
  5. Who takes care of checking my eligibility for incentives, according to the installation date?

We are comfortable answering these five questions. If an installer does not answer them, that is a signal to take seriously.

Technical data

  • model: CHPTA3630C3, cased evaporator coil, CHPTA range;
  • nominal size: 2.5 to 3 tons (36,000 BTU/h);
  • refrigerant: R-32;
  • metering device: TXV;
  • connections: 3/8 in liquid, 7/8 in suction;
  • published position: horizontal;
  • leak detection: R-32 refrigerant sensor designed to last the life of the coil;
  • 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).

The AHRI number, the real judge of efficiency

This coil carries no efficiency rating by itself. SEER2, EER2 and HSPF2 relate to a complete system, identified by an AHRI number that links a specific coil and a specific outdoor unit. We confirm it before the order. When we checked on 2026-11-26, no R-32 match with this model was listed in the ENERGY STAR data set.

Where it sits in the range

  • Twin brother, shorter cabinet: CHPTA3630B3;
  • A bit more capacity on the same width and the same height: CHPTA4230C3, from 2.5 to 3.5 tons;
  • Narrower: CHPTA3026B3 and CHPTA3026C3, from 2 to 2.5 tons, on 26 in;
  • Much larger: CHPTA4830C3 and CHPTA6030D3, from 3.5 to 5 tons;
  • Smaller: CHPTA1822A3, CHPTA1822B3, CHPTA2426B3 and CHPTA2426C3.

What we do at your home

AirGreen is a family-owned heating and cooling company established in Montreal for more than fifteen years. We work under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. The installation includes:

  • measuring the furnace, and checking the blower and the panel;
  • the cabinet in the plenum, with a transition built if needed, and sealing the joints;
  • the outdoor unit, brazed piping, nitrogen test and vacuum;
  • connecting the drain and the thermostat;
  • commissioning and explanations.

Notes before buying

  • R-32 refrigerant: the outdoor unit must be of the same type and installed at the same time.
  • The published ratings apply to the certified match.
  • The furnace must be 30 in wide and have a blower capable of the airflow required.

When the 21 in height makes the difference

In a home where the supply plenum is wide and tall, this cabinet fits in naturally. The air path above the fins is longer, the transition to the ducts is gentler, and access to the pan for maintenance is easier. In a narrow mechanical room, the same height can become an obstacle. Hence the importance of the measurement taken before the order.

The manufacturer

Goodman is a member of Daikin Comfort Technologies, just like Daikin and Amana. Its R-32 coils go with new-generation heat pumps and central air conditioners, on a furnace or a modular blower.

Incentives

Eligibility for Hydro-Québec programs depends on the complete system and the installation date, not on the coil alone. We check the official list during the quote and spell out what applies.

Book your visit

Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The CHPTA3630C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Goodman outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-32 refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerGoodman
ModelCHPTA3630C3
TypeCased evaporator coil
LineCHPTA
Nominal size2.5 to 3 tons (36,000 BTU/h)
RefrigerantR-32
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D30 × 21 × 21 in
Model numberCHPTA3630C3
03 · Before installing

What to know before installing

  • R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 30 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
GOODMAN
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2.5 to 3-ton Goodman coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.