GOODMAN CHPTA4230C3 Evaporator A-Coil | 2.5 to 3.5 Tons
The Goodman CHPTA4230C3 2.5 to 3.5-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCHPTA4230C3
514 316-2973 · sales@airgreen.ca
Quick facts
CHPTA4230C3: the wide-range Goodman coil, from 2.5 to 3.5 tons on 30 in
Most coils in the series cover half a ton or one ton. The Goodman CHPTA4230C3 evaporator coil spans a full ton, from 2.5 to 3.5 tons (42,000 BTU/h nominal). This range overlaps that of the CHPTA3630B3 and CHPTA3630C3 on one side, and that of the CHPTA4830C3 on the other. It therefore serves as a pivot for homes whose load does not fit neatly into one box.
We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Its footprint is 30 × 21 × 21 in, with R-32 and the TXV.
The overlap, explained with a mental chart
Picture the series on an axis, from the smallest range to the largest:
- CHPTA3630B3 and CHPTA3630C3: from 2.5 to 3 tons;
- CHPTA4230C3: from 2.5 to 3.5 tons;
- CHPTA4830C3: from 3.5 to 4 tons;
- CHPTA6030D3: from 4 to 5 tons.
Your home may fall into several ranges at once. A 3 ton load, for example, is covered by the first three models on the list. In that case, capacity is no longer the deciding criterion; it is the available height, the preferred match with the outdoor unit and the margin you want to have for the future.
When to choose the 4230 over the 3630
Choose the CHPTA4230C3 when the calculated load approaches the top of the 3 ton bracket, when an addition is planned (a basement being finished, an extra floor, a sunroom), or when you want some leeway for summers that are getting hotter. The footprint is identical to that of the CHPTA3630C3: same 30 in width, same 21 in height, same depth. The larger range comes from a different exchange surface and match, not from a bigger cabinet.
Stay with the 3630 if the load is clearly under 3 tons. A system bigger than necessary brings no extra comfort; it short-cycles and leaves the humidity.
When the 4830 becomes more reasonable
If the load calculation exceeds 3.5 tons, this coil reaches its limit. The CHPTA4830C3 then takes over, with a range of 3.5 to 4 tons on the same 30 in width. We never force a coil to work beyond its nominal range. The opposite is true too: we do not propose this model simply because its range looks more reassuring.
An enlarged home: an example
A couple in Longueuil bought a bungalow, then added a back room and finished the basement. Their old air conditioner, sized for the original house, can no longer keep up. The load calculation, redone after the work, falls in the upper part of this coil's range. A more modest model would have run continuously on heat wave days; a clearly bigger one would have short-cycled. The CHPTA4230C3, with the right outdoor unit, offers the right balance.
The lesson is simple: redo the load calculation whenever the home changes. A replaced window, an insulated attic, an added room all change the needs, sometimes in one direction and sometimes in the other.
CHPTA4230C3 spec sheet
- type: cased evaporator coil, CHPTA range, A shape;
- nominal size: 2.5 to 3.5 tons (42,000 BTU/h);
- refrigerant: R-32; metering device: TXV;
- dimensions W × H × D: 30 × 21 × 21 in;
- liquid connection: 3/8 in; suction: 7/8 in;
- published installation position: horizontal;
- R-32 refrigerant sensor designed to last the life of the coil;
- 10-year limited parts warranty, online registration within 60 days of installation (not required in Quebec).
How the outdoor unit is chosen
The coil pairs with a Goodman outdoor unit of the same capacity and the same refrigerant. Because its range is wide, several outdoor units may suit it; each forms a different certified system with it, with its own AHRI number and its own SEER2, EER2 and HSPF2 ratings. The coil itself has no efficiency rating of its own.
Our job is to select the unit that matches the calculated load, then confirm the AHRI number in the directory. As of 2026-11-26, the ENERGY STAR data set showed no R-32 match with this coil; AHRI therefore remains the reference.
Heat pump warmth and the furnace's role
With a heat pump, the coil heats in winter, through the same ducts that serve the air conditioning. The furnace keeps its role: it takes over below the temperature threshold that we program with you. A heat pump moves heat instead of creating it, which allows it to supply, in mild weather, two to three times more heat than the electricity consumed. Its performance declines as the cold intensifies, hence the usefulness of the backup.
For a system this size, the blower must provide a considerable airflow. We check it carefully and, if it is not up to it, we tell you before you sign.
What our installation includes
AirGreen is a family-owned heating and cooling company, established in Montreal for more than fifteen years and holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. Our installation includes:
- measuring the furnace and plenum, and checking the blower and the electrical panel;
- installing the cabinet, with an insulated transition if needed, and sealing the duct joints;
- installing the outdoor unit, brazed piping, nitrogen test and vacuum;
- connecting the condensate drain and the thermostat;
- commissioning, airflow adjustment and the walk-through.
Before ordering
- R-32 requires an outdoor unit with the same refrigerant, installed at the same time.
- The published ratings apply to the certified match, not to the coil alone.
- The furnace must be 30 in wide and have a suitable blower.
About Goodman
The brand is part of Daikin Comfort Technologies, with Daikin and Amana. Its R-32 coils equip recent central systems, on a furnace or on a modular blower.
Incentives
Hydro-Québec programs apply to the complete system, according to the installation date, not to the coil alone. We check the official list at the time of the quote, then indicate what concerns your project.
Receive your quote
Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CHPTA4230C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 30 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 2.5 to 3.5-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.