GOODMAN CHPTA2426C3 Evaporator A-Coil | 1.5 to 2 Tons
The Goodman CHPTA2426C3 1.5 to 2-ton R-32 cased coil sits on your furnace and, matched with a matching Goodman outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberCHPTA2426C3
514 316-2973 · sales@airgreen.ca
Quick facts
Goodman CHPTA2426C3: a 21 in high cabinet for 1.5 to 2 tons on a 26 in furnace
Three things to know about the Goodman CHPTA2426C3 evaporator coil, before you even read the spec sheet. One: its nominal range covers 1.5 to 2 tons. Two: it is 26 in wide. Three: its cabinet is 21 in high, which sets it apart from its twin, the CHPTA2426B3. Everything else follows from these three facts.
AirGreen installs it for homeowners in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, when the furnace has some height at the top of the plenum.
What an evaporator coil is for, in plain terms
Picture a car radiator working in reverse. Instead of getting rid of engine heat, it removes heat from the air in your home. Cold refrigerant flows through the copper tubes, the warm air from your rooms passes between the fins, and heat moves from one to the other. The cooled air returns to the vents, while the heat goes to the outdoor unit.
The CHPTA2426C3 is an A-coil: two sloped panels that meet at the top. The air rises through the centre and passes through both faces, which gives a large exchange surface in a compact volume. It comes in an insulated cabinet, ready to sit on the furnace.
Why 21 in of height
Published dimensions: 26 × 21 × 21 in. The extra height compared with the B3 gives a longer air path and a roomier cabinet where the air crosses the heat exchanger. For the homeowner, this means more ease during installation and maintenance, provided the space exists above the furnace.
So it is the available height, more than capacity, that guides the choice between the B3 and the C3. If the ceiling of your mechanical room is close to the plenum, the shorter cabinet of the B3 will make more sense. Otherwise, the C3 goes in without constraint. We measure with a tape, not by eye.
Spec sheet summary
- CHPTA2426C3, cased evaporator coil, CHPTA range;
- nominal size: 1.5 to 2 tons, 24,000 BTU/h;
- R-32 refrigerant and TXV metering device;
- 3/8 in liquid line, 7/8 in suction line;
- published position: horizontal;
- leak detection: R-32 refrigerant sensor, designed to last the life of the coil;
- 10-year limited parts warranty; online registration within 60 days of installation is not required in Quebec.
How an installation day unfolds
Here is what you can expect on the day, in the order things usually happen with us:
- in the morning, the crew protects the floors, shuts off the power and opens the furnace plenum;
- the cabinet goes in, with a custom-built insulated transition if the furnace width differs from 26 in;
- outside, the unit is set on a stable base, then the copper piping is run and brazed;
- the circuit is pressurized with nitrogen to look for leaks, then pulled into a vacuum;
- the condensate drain and the thermostat are connected;
- the system starts up, the airflow is adjusted, and a technician explains everything at your pace.
Before that day, an estimate visit has already measured the furnace and checked the electrical panel. No surprise should show up that same morning.
Matching with the outdoor unit
The coil does not work alone. It pairs with a Goodman outdoor unit of the same capacity and the same refrigerant, installed at the same time. This pair is identified by an AHRI number. It is this number, not the coil by itself, that carries the SEER2, EER2 and HSPF2 ratings. We confirm it in the directory before ordering.
Information checked on 2026-11-26: no R-32 match with this coil currently appears in the ENERGY STAR data. The AHRI directory remains the reference for the outdoor unit chosen.
Placing the C3 in the series
- Same range, shorter cabinet: CHPTA2426B3;
- Smaller: CHPTA1822A3 and CHPTA1822B3, for 1.5 ton and 22 in wide;
- One step up: CHPTA3026B3 and CHPTA3026C3, from 2 to 2.5 tons, still 26 in. The C3's footprint is found there unchanged, with more capacity;
- 30 in width: CHPTA3630B3, CHPTA3630C3, CHPTA4230C3, CHPTA4830C3 and CHPTA6030D3, from 2.5 to 5 tons.
All eleven models have the same R-32 and the same TXV. So you are comparing three parameters: capacity, width, height.
Maintenance: what the height makes easier
A coil does not demand much attention, but it must stay clean. Dust that gets through a worn-out filter settles on the fins and reduces airflow. A 21 in cabinet leaves a little more clearance to inspect the face of the coil and the pan that collects the condensation water.
Our advice is to plan a yearly check, preferably in spring, before the air conditioning season. It includes inspecting the pan, checking the drain, the condition of the filter and a look at the connections. A preventive check is better than an overflowing pan in the middle of July.
Heating with a heat pump without throwing out the furnace
When the outdoor unit is a heat pump, the system heats in winter along the same path that cools in summer. The furnace is not shelved: it keeps its blower, its filters and its role as backup in very cold weather. We set with you the temperature threshold at which it takes over, so that the backup heat is used only when the heat pump is no longer enough.
The blower must still provide the system's airflow, which we check at the visit.
What we check before quoting
- R-32 requires an outdoor unit with the same refrigerant;
- the published ratings apply only to the certified match;
- the furnace width and the blower capacity.
The company that installs it
AirGreen is a family-owned heating and cooling company established in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01.
About the brand
Goodman is part of Daikin Comfort Technologies, alongside Daikin and Amana. The brand's R-32 coils go with new-generation central air conditioners and heat pumps, on a furnace or on a modular blower.
Incentives
Hydro-Québec programs assess the complete system, not the coil alone, and according to the installation date. We validate the match against the official list while preparing your quote, then explain what your project may qualify for.
Have your furnace measured
Request your free on-site estimate: we measure the furnace, check the electrical entrance and give you a written quote for the complete Goodman system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The CHPTA2426C3 sits in the plenum of a furnace or air handler. Connected to a matching Goodman outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Goodman outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-32 refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 26 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
GOODMANSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-32 and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 1.5 to 2-ton Goodman coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.