Five rooms: only the biggest outdoor units keep up.
Five heads is the printed maximum for the 48,000 DLCMRA and the DLCMHB 48HH, now at the end of its series. We also sell the 48,000 and 55,000 D5CMHA as 5-zone, to be confirmed per size. Pick the unit and the temperature: you see its heat for the whole system and what that works out to per head, on average.
Five heads on one unit: how much heat for each, on average?
System values come from NEEP or, for the DLCMRA, the 2018 catalogue. The per-head average is our calculation: the system value divided by five.
Outdoor unit
Outdoor temperature
Heat per head, on average (our calculation)
Five 9,000 heads do not ask for the same thing as five 12,000 heads. The heads are chosen at the visit; the average helps compare the outdoor units.
45,000 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
47,000 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
24,600 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
47,000 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
47,000 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
26,400 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
39,000 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
45,000 BTU/h for the whole system (NEEP), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
No value published for this unit at this temperature in the sources we hold.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
No value published for this unit at this temperature in the sources we hold.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
37,900 BTU/h for the whole system (2018 catalogue, not certified), divided by 5: our calculation.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
No value published for this unit at this temperature in the sources we hold.
Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.
Averages rounded to the nearest ten. At -8 °C the value shown is the rated heat; at -15 and -30 °C, the maximum heat. NEEP lists no -30 °C point for the DLCMHB 48HH; the DLCMRA is listed by neither NEEP nor ENERGY STAR, and its catalogue gives only a maximum at -15 °C (5 °F).
All 4 ARCOAIRE 5-zone systems, right below.
Each product gives the outdoor unit, the combinations of heads offered and, when there is one, the AHRI number and the indicative LogisVert amount. Pricing by quote.
The four 5-zone units, and the twelve printed combinations.
The system heat, unit by unit; then every five-head combination the manufacturer prints for the 48,000 DLCMRA.
| Outdoor unit | Max. heads | Rated at -8 °C | Maximum at -15 °C | Maximum at -30 °C | SEER2 | Indicative LogisVert | |
|---|---|---|---|---|---|---|---|
| D5CMHA · R-454B | |||||||
| 48,000 BTU D5CMHAH48FAK | not published | 45,000 NEEP | 47,000 NEEP | 24,600 NEEP | 23 | $5,400 | |
| 55,000 BTU D5CMHAH55FAK | not published | 47,000 NEEP | 47,000 NEEP | 26,400 NEEP | 22.3 | $5,640 | |
| DLCMHB · R-410A, high heat · end of series | |||||||
| 48,000 BTU DLCMHBH48EAK | 5 | 39,000 NEEP | 45,000 NEEP | not published | 21.2 | $4,680 | |
| DLCMRA · R-410A | |||||||
| 48,000 BTU DLCMRAH48EAK | 5 | not published | 37,900 2018 catalogue, not certified | not published | no SEER2 rating | none on our sheets | |
48,000 BTU · 12 five-head combinations
In thousands of BTU/h, as printed in the 2018 catalogue, p. 48. Every 5-zone variant on our DLCMRA product page is in it. For the DLCMHB 48HH, there is no combination chart: we read one range per wall head in the 2024 catalogue (p. 21), in merged cells with no borders, and we confirm it before the quote. For the D5CMHA, no chart in the documents we hold.
Five line sets to run: the manufacturer’s limits.
The limits the manufacturer prints in its catalogues for the DLCMRA and the DLCMHB, and those on its web page for the D5CMHA. The total length adds up all five line sets. For the DLCMRA and the DLCMHB, the printed maximum height difference is the same whether the outdoor unit sits above or below the heads.
| Outdoor unit | Total length | Farthest head | Height difference | |
|---|---|---|---|---|
| D5CMHA · R-454B | ||||
| D5CMHA 48,000 and 55,000 BTU | 197 to 262.5 ft family, depending on size; manufacturer web page | not published | 49 to 65 ft (lift or drop) family, depending on size; manufacturer web page | |
| DLCMHB · R-410A, high heat · end of series | ||||
| 48,000 BTU DLCMHBH48EAK | 328 ft (100 m) | 115 ft (35 m) | 65 ft (20 m) | |
| DLCMRA · R-410A | ||||
| 48,000 BTU DLCMRAH48EAK | 328 ft (100 m) | 115 ft (35 m) | 65 ft (20 m) | |
DLCMRA: ARCOAIRE ductless catalogue 328-32-0499-00 (May 2018), p. 46. DLCMHB: ARCOAIRE ductless catalogue DLS-001-AR-01 (March 2024), p. 47. D5CMHA: manufacturer web page (arcoaire.com), read November 5, 2026, values given in feet for the whole family, depending on size; no per-size value is published.
Three things the manufacturer’s charts tell you.
With five heads, only one combination takes a 24,000.
On the 48,000 DLCMRA: 9 + 9 + 9 + 9 + 24 (thousands of BTU/h). The other eleven use only 9,000 to 18,000 heads.
ARCOAIRE ductless catalogue 328-32-0499-00, May 2018, p. 48The biggest combinations add up to 63,000 BTU/h of heads.
9 + 9 + 9 + 18 + 18 and 9 + 12 + 12 + 12 + 18: 131% of the 48,000 unit’s size (our calculation from the chart).
ARCOAIRE ductless catalogue 328-32-0499-00, May 2018, p. 48Up to 100 m of total piping, for five heads.
That is the length printed for the 48,000 DLCMRA and the DLCMHB 48HH, with the farthest head at 115 ft (35 m).
Catalogue 328-32-0499-00, p. 46; catalogue DLS-001-AR-01, p. 47What people ask us about 5-zone systems.
Five heads on one unit: is that reasonable?
The manufacturer prints five heads for the 48,000 DLCMRA and the 48HH; for the D5CMHA, it is a configuration we sell, to be confirmed per size. The more heads, the more the system’s heat is shared: compare the per-head average in the tool, and think of the rooms that need the most.
Why is the per-head average only a guide?
Because heat goes where it is called for. A north bedroom and a bathroom do not take the same share. The average helps compare units with each other, not size a room.
Why “not published” for some temperatures?
We only show values listed by NEEP or printed by the manufacturer. NEEP lists no -30 °C point for the DLCMHB 48HH, and the DLCMRA catalogue gives only a maximum at -15 °C.
And the 55,000 D5CMHA: how many heads at most?
The documents we hold state up to six indoor units for the family, with no maximum per size. We sell it up to 5 zones; the maximum per size is confirmed before any quote.
What about LogisVert?
It is indicative and taken from our product sheets: the DLCMRA has none on our sheets. Only Hydro-Québec confirms the amount granted.
How do you choose the five heads?
At the visit, room by room. Then we check the combination, the total length of the five line sets and where the outdoor unit goes.
Five rooms, a unit that keeps up.
We size each room, choose the five heads, then check the combination and the line-set lengths against the manufacturer’s documents. You get a quote with the system and its AHRI number when it has one.
Sources checked on October 29, 2026
- ARCOAIRE ductless catalogue 328-32-0499-00 (May 2018), pp. 46 and 48 (printed page numbers): DLCMRA, specifications and combination chart, re-read October 29, 2026.
- ARCOAIRE ductless catalogue DLS-001-AR-01 (March 2024), pp. 21 and 46 to 48: DLCMHB.
- ARCOAIRE Deluxe Series brochure DLS-030-AR-02 (June 2026), p. 2: D5CMHA.
- Manufacturer web page (arcoaire.com), read November 5, 2026 (“D5CMHA - Deluxe Multi-Zone Heat Pump”): D5CMHA line-set lengths.
- NEEP cold-climate heat pump list, records 390097, 390103, 405758, modified August 24, 2026, read October 28, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market (D5CMHAH48FAK 3556880, D5CMHAH55FAK 3556883, DLCMHBH48EAK 2410134), read October 28, 2026.
- airgreen.ca product sheets (combinations offered, sale status, indicative LogisVert amounts), re-read October 29, 2026.
LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.