AirGreenARCOAIRE
AirGreen × ARCOAIRE · Multi-zone · 5 zonesFive rooms, one outdoor unitSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full ARCOAIRE range
  1. Home
  2. ARCOAIRE
  3. Multi-zone
  4. 5 zones
ARCOAIRE 5-zone heat pump · Updated October 29, 2026

Five rooms: only the biggest outdoor units keep up.

Five heads is the printed maximum for the 48,000 DLCMRA and the DLCMHB 48HH, now at the end of its series. We also sell the 48,000 and 55,000 D5CMHA as 5-zone, to be confirmed per size. Pick the unit and the temperature: you see its heat for the whole system and what that works out to per head, on average.

4outdoor units sold as 5-zone systems
12five-head combinations in the 48,000 DLCMRA chart
328 ftof total piping for both 48,000 R-410A units (100 m)
48,000 and 55,000BTU, the two sizes sold as 5-zone
01 · Per head

Five heads on one unit: how much heat for each, on average?

System values come from NEEP or, for the DLCMRA, the 2018 catalogue. The per-head average is our calculation: the system value divided by five.

Outdoor unit

Outdoor temperature

Heat per head, on average (our calculation)

D5CMHA 48,000R-454B
4,920 BTU/h
D5CMHA 55,000R-454B
5,280 BTU/h
DLCMHB 48,000R-410A
not published
DLCMRA 48,000R-410A
not published

Five 9,000 heads do not ask for the same thing as five 12,000 heads. The heads are chosen at the visit; the average helps compare the outdoor units.

55,000 BTU · D5CMHAH55FAK · Maximum at -30 °C
5,280BTU/h per head, on average

26,400 BTU/h for the whole system (NEEP), divided by 5: our calculation.

Rated at -8 °C47,000 BTU/h
Maximum at -15 °C47,000 BTU/h
Maximum at -30 °C26,400 BTU/h

Heat is not split in equal shares: it goes to the rooms that call for it. The average only helps compare the units.

Averages rounded to the nearest ten. At -8 °C the value shown is the rated heat; at -15 and -30 °C, the maximum heat. NEEP lists no -30 °C point for the DLCMHB 48HH; the DLCMRA is listed by neither NEEP nor ENERGY STAR, and its catalogue gives only a maximum at -15 °C (5 °F).

The shop

All 4 ARCOAIRE 5-zone systems, right below.

Each product gives the outdoor unit, the combinations of heads offered and, when there is one, the AHRI number and the indicative LogisVert amount. Pricing by quote.

ARCOAIRE
02 · The combinations

The four 5-zone units, and the twelve printed combinations.

The system heat, unit by unit; then every five-head combination the manufacturer prints for the 48,000 DLCMRA.

Outdoor unitMax. headsRated at -8 °CMaximum at -15 °CMaximum at -30 °CSEER2Indicative LogisVert
D5CMHA · R-454B
48,000 BTU
D5CMHAH48FAK
not published45,000
NEEP
47,000
NEEP
24,600
NEEP
23$5,400
55,000 BTU
D5CMHAH55FAK
not published47,000
NEEP
47,000
NEEP
26,400
NEEP
22.3$5,640
DLCMHB · R-410A, high heat · end of series
48,000 BTU
DLCMHBH48EAK
539,000
NEEP
45,000
NEEP
not published21.2$4,680
DLCMRA · R-410A
48,000 BTU
DLCMRAH48EAK
5not published37,900
2018 catalogue, not certified
not publishedno SEER2 ratingnone on our sheets
DLCMRAH48EAK

48,000 BTU · 12 five-head combinations

9 + 9 + 9 + 9 + 99 + 9 + 9 + 9 + 129 + 9 + 9 + 9 + 189 + 9 + 9 + 9 + 249 + 9 + 9 + 12 + 129 + 9 + 9 + 12 + 189 + 9 + 9 + 18 + 189 + 9 + 12 + 12 + 129 + 9 + 12 + 12 + 189 + 12 + 12 + 12 + 129 + 12 + 12 + 12 + 1812 + 12 + 12 + 12 + 12

In thousands of BTU/h, as printed in the 2018 catalogue, p. 48. Every 5-zone variant on our DLCMRA product page is in it. For the DLCMHB 48HH, there is no combination chart: we read one range per wall head in the 2024 catalogue (p. 21), in merged cells with no borders, and we confirm it before the quote. For the D5CMHA, no chart in the documents we hold.

03 · The line sets

Five line sets to run: the manufacturer’s limits.

The limits the manufacturer prints in its catalogues for the DLCMRA and the DLCMHB, and those on its web page for the D5CMHA. The total length adds up all five line sets. For the DLCMRA and the DLCMHB, the printed maximum height difference is the same whether the outdoor unit sits above or below the heads.

Outdoor unitTotal lengthFarthest headHeight difference
D5CMHA · R-454B
D5CMHA
48,000 and 55,000 BTU
197 to 262.5 ft
family, depending on size; manufacturer web page
not published49 to 65 ft (lift or drop)
family, depending on size; manufacturer web page
DLCMHB · R-410A, high heat · end of series
48,000 BTU
DLCMHBH48EAK
328 ft (100 m)115 ft (35 m)65 ft (20 m)
DLCMRA · R-410A
48,000 BTU
DLCMRAH48EAK
328 ft (100 m)115 ft (35 m)65 ft (20 m)

DLCMRA: ARCOAIRE ductless catalogue 328-32-0499-00 (May 2018), p. 46. DLCMHB: ARCOAIRE ductless catalogue DLS-001-AR-01 (March 2024), p. 47. D5CMHA: manufacturer web page (arcoaire.com), read November 5, 2026, values given in feet for the whole family, depending on size; no per-size value is published.

Did you know

Three things the manufacturer’s charts tell you.

Just 1

With five heads, only one combination takes a 24,000.

On the 48,000 DLCMRA: 9 + 9 + 9 + 9 + 24 (thousands of BTU/h). The other eleven use only 9,000 to 18,000 heads.

ARCOAIRE ductless catalogue 328-32-0499-00, May 2018, p. 48
131%

The biggest combinations add up to 63,000 BTU/h of heads.

9 + 9 + 9 + 18 + 18 and 9 + 12 + 12 + 12 + 18: 131% of the 48,000 unit’s size (our calculation from the chart).

ARCOAIRE ductless catalogue 328-32-0499-00, May 2018, p. 48
328 ft

Up to 100 m of total piping, for five heads.

That is the length printed for the 48,000 DLCMRA and the DLCMHB 48HH, with the farthest head at 115 ft (35 m).

Catalogue 328-32-0499-00, p. 46; catalogue DLS-001-AR-01, p. 47
04 · Questions

What people ask us about 5-zone systems.

Five heads on one unit: is that reasonable?

The manufacturer prints five heads for the 48,000 DLCMRA and the 48HH; for the D5CMHA, it is a configuration we sell, to be confirmed per size. The more heads, the more the system’s heat is shared: compare the per-head average in the tool, and think of the rooms that need the most.

Why is the per-head average only a guide?

Because heat goes where it is called for. A north bedroom and a bathroom do not take the same share. The average helps compare units with each other, not size a room.

Why “not published” for some temperatures?

We only show values listed by NEEP or printed by the manufacturer. NEEP lists no -30 °C point for the DLCMHB 48HH, and the DLCMRA catalogue gives only a maximum at -15 °C.

And the 55,000 D5CMHA: how many heads at most?

The documents we hold state up to six indoor units for the family, with no maximum per size. We sell it up to 5 zones; the maximum per size is confirmed before any quote.

What about LogisVert?

It is indicative and taken from our product sheets: the DLCMRA has none on our sheets. Only Hydro-Québec confirms the amount granted.

How do you choose the five heads?

At the visit, room by room. Then we check the combination, the total length of the five line sets and where the outdoor unit goes.

AirGreen × ARCOAIRE

Five rooms, a unit that keeps up.

We size each room, choose the five heads, then check the combination and the line-set lengths against the manufacturer’s documents. You get a quote with the system and its AHRI number when it has one.

RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
Free on-site estimateHead sizes, the combination and the route of the five line sets are decided at your home, once we have seen the rooms and the electrical panel.
Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.

Sources checked on October 29, 2026

  1. ARCOAIRE ductless catalogue 328-32-0499-00 (May 2018), pp. 46 and 48 (printed page numbers): DLCMRA, specifications and combination chart, re-read October 29, 2026.
  2. ARCOAIRE ductless catalogue DLS-001-AR-01 (March 2024), pp. 21 and 46 to 48: DLCMHB.
  3. ARCOAIRE Deluxe Series brochure DLS-030-AR-02 (June 2026), p. 2: D5CMHA.
  4. Manufacturer web page (arcoaire.com), read November 5, 2026 (“D5CMHA - Deluxe Multi-Zone Heat Pump”): D5CMHA line-set lengths.
  5. NEEP cold-climate heat pump list, records 390097, 390103, 405758, modified August 24, 2026, read October 28, 2026.
  6. ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market (D5CMHAH48FAK 3556880, D5CMHAH55FAK 3556883, DLCMHBH48EAK 2410134), read October 28, 2026.
  7. airgreen.ca product sheets (combinations offered, sale status, indicative LogisVert amounts), re-read October 29, 2026.

LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.