Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
Through your ducts down to -30 °C: three certified ARCOAIRE pairings.
The D5CUHA (R-454B) and the DLCURA (R-410A) are on NEEP’s cold-climate list. Pick a size: each certified pairing shows its heat at -8, -15 and -30 °C, its efficiency and its indicative LogisVert amount.
Same size, three pairings: compare their heat at -30 °C.
Tap a size. Each column is a certified system: one outdoor unit and one indoor unit under a single AHRI number. Figures from NEEP and ENERGY STAR Canada, read October 28, 2026.
System size
Maximum heat at -30 °C (-22 °F), as listed by NEEP
Most heat at -30 °C for this size: D5CUHA + D5FUAA.
Maximums as listed by NEEP at -22 °F. LogisVert amounts from our product sheets: only Hydro-Québec confirms the amount granted.
Most heat at -30 °C for this size: DLCURA + DLFUAA.
Maximums as listed by NEEP at -22 °F. LogisVert amounts from our product sheets: only Hydro-Québec confirms the amount granted.
Most heat at -30 °C for this size: D5CUHA + D5FUAA.
Maximums as listed by NEEP at -22 °F. LogisVert amounts from our product sheets: only Hydro-Québec confirms the amount granted.
Most heat at -30 °C for this size: D5CUHA + D5FUAA.
Maximums as listed by NEEP at -22 °F. LogisVert amounts from our product sheets: only Hydro-Québec confirms the amount granted.
Most heat at -30 °C for this size: D5CUHA + D5FUHA.
Maximums as listed by NEEP at -22 °F. LogisVert amounts from our product sheets: only Hydro-Québec confirms the amount granted.
Most heat at -30 °C for this size: D5CUHA + D5FUHA.
Maximums as listed by NEEP at -22 °F. LogisVert amounts from our product sheets: only Hydro-Québec confirms the amount granted.
D5CUHA + D5FUAA
D5CUHAH18AAK + D5FUAAH18XAK- Rated heat at -8 °C
- 15,000 BTU/h
- Maximum at -15 °C
- 18,000 BTU/h
- Maximum at -30 °C
- 12,000 BTU/h
- SEER2
- 19.0
- HSPF2 (region IV)
- 9.8
- AHRI
- 215318887
- ENERGY STAR Canada
- 3560725
- Indicative LogisVert
- $1,800
D5CUHA + D5FUHA
D5CUHAH18AAK + D5FUHAH24XAK- Rated heat at -8 °C
- 14,700 BTU/h
- Maximum at -15 °C
- 18,600 BTU/h
- Maximum at -30 °C
- 11,800 BTU/h
- SEER2
- 19.0
- HSPF2 (region IV)
- 10.2
- AHRI
- 215318901
- ENERGY STAR Canada
- 3560735
- Indicative LogisVert
- $1,764
DLCURA + DLFUAA
DLCURAH18ABK + DLFUAAH18XAK- Rated heat at -8 °C
- 13,500 BTU/h
- Maximum at -15 °C
- 16,500 BTU/h
- Maximum at -30 °C
- 10,500 BTU/h
- SEER2
- 18.0
- HSPF2 (region IV)
- 9.3
- AHRI
- 209852036
- ENERGY STAR Canada
- 2460665
- Indicative LogisVert
- $1,620
D5CUHA + D5FUAA
D5CUHAH24AAK + D5FUAAH24XAK- Rated heat at -8 °C
- 20,800 BTU/h
- Maximum at -15 °C
- 21,600 BTU/h
- Maximum at -30 °C
- 12,000 BTU/h
- SEER2
- 18.4
- HSPF2 (region IV)
- 10.0
- AHRI
- 215318888
- ENERGY STAR Canada
- 3560726
- Indicative LogisVert
- $2,496
D5CUHA + D5FUHA
D5CUHAH24AAK + D5FUHAH24XAK- Rated heat at -8 °C
- 20,800 BTU/h
- Maximum at -15 °C
- 20,600 BTU/h
- Maximum at -30 °C
- 12,100 BTU/h
- SEER2
- 18.7
- HSPF2 (region IV)
- 10.0
- AHRI
- 215318889
- ENERGY STAR Canada
- 3560928
- Indicative LogisVert
- $2,496
DLCURA + DLFUAA
DLCURAH24ABK + DLFUAAH24XAK- Rated heat at -8 °C
- 19,200 BTU/h
- Maximum at -15 °C
- 22,600 BTU/h
- Maximum at -30 °C
- 13,400 BTU/h
- SEER2
- 17.4
- HSPF2 (region IV)
- 10.0
- AHRI
- 209852037
- ENERGY STAR Canada
- 2460662
- Indicative LogisVert
- $2,304
D5CUHA + D5FUAA
D5CUHAH30AAK + D5FUAAH30XAK- Rated heat at -8 °C
- 23,800 BTU/h
- Maximum at -15 °C
- 32,600 BTU/h
- Maximum at -30 °C
- 20,100 BTU/h
- SEER2
- 16.9
- HSPF2 (region IV)
- 10.0
- AHRI
- 215318890
- ENERGY STAR Canada
- 3560727
- Indicative LogisVert
- $2,856
D5CUHA + D5FUHA
D5CUHAH30AAK + D5FUHAH36XAK- Rated heat at -8 °C
- 24,000 BTU/h
- Maximum at -15 °C
- 33,200 BTU/h
- Maximum at -30 °C
- 17,900 BTU/h
- SEER2
- 17.2
- HSPF2 (region IV)
- 10.8
- AHRI
- 215318902
- ENERGY STAR Canada
- 3560736
- Indicative LogisVert
- $2,880
DLCURA + DLFUAA
DLCURAH30ABK + DLFUAAH30XAK- Rated heat at -8 °C
- 21,000 BTU/h
- Maximum at -15 °C
- 24,000 BTU/h
- Maximum at -30 °C
- 13,700 BTU/h
- SEER2
- 16.2
- HSPF2 (region IV)
- 8.9
- AHRI
- 209852044
- ENERGY STAR Canada
- 2464961
- Indicative LogisVert
- $2,520
D5CUHA + D5FUAA
D5CUHAH36AAK + D5FUAAH36XAK- Rated heat at -8 °C
- 31,800 BTU/h
- Maximum at -15 °C
- 39,000 BTU/h
- Maximum at -30 °C
- 27,800 BTU/h
- SEER2
- 17.4
- HSPF2 (region IV)
- 10.3
- AHRI
- 215318891
- ENERGY STAR Canada
- 3560728
- Indicative LogisVert
- $3,816
D5CUHA + D5FUHA
D5CUHAH36AAK + D5FUHAH36XAK- Rated heat at -8 °C
- 33,000 BTU/h
- Maximum at -15 °C
- 37,400 BTU/h
- Maximum at -30 °C
- 27,600 BTU/h
- SEER2
- 18.0
- HSPF2 (region IV)
- 10.0
- AHRI
- 215323725
- ENERGY STAR Canada
- 3560981
- Indicative LogisVert
- $3,960
DLCURA + DLFUAA
DLCURAH36ABK + DLFUAAH36XAK- Rated heat at -8 °C
- 30,400 BTU/h
- Maximum at -15 °C
- 34,400 BTU/h
- Maximum at -30 °C
- 21,500 BTU/h
- SEER2
- 16.0
- HSPF2 (region IV)
- 9.5
- AHRI
- 209852043
- ENERGY STAR Canada
- 2464964
- Indicative LogisVert
- $3,648
D5CUHA + D5FUAA
D5CUHAH48AAK + D5FUAAH48XAK- Rated heat at -8 °C
- 39,500 BTU/h
- Maximum at -15 °C
- 46,000 BTU/h
- Maximum at -30 °C
- 25,900 BTU/h
- SEER2
- 16.5
- HSPF2 (region IV)
- 9.5
- AHRI
- 215318892
- ENERGY STAR Canada
- 3560729
- Indicative LogisVert
- $4,740
D5CUHA + D5FUHA
D5CUHAH48AAK + D5FUHAH60XAK- Rated heat at -8 °C
- 39,500 BTU/h
- Maximum at -15 °C
- 48,000 BTU/h
- Maximum at -30 °C
- 27,200 BTU/h
- SEER2
- 17.5
- HSPF2 (region IV)
- 9.5
- AHRI
- 215318903
- ENERGY STAR Canada
- 3560737
- Indicative LogisVert
- $4,740
DLCURA + DLFUAA
DLCURAH48ABK + DLFUAAH48XAK- Rated heat at -8 °C
- 36,000 BTU/h
- Maximum at -15 °C
- 46,000 BTU/h
- Maximum at -30 °C
- 24,500 BTU/h
- SEER2
- 15.6
- HSPF2 (region IV)
- 9.4
- AHRI
- 209852039
- ENERGY STAR Canada
- 2464963
- Indicative LogisVert
- $4,320
D5CUHA + D5FUAA
D5CUHAH60AAK + D5FUAAH60XAK- Rated heat at -8 °C
- 45,000 BTU/h
- Maximum at -15 °C
- 52,000 BTU/h
- Maximum at -30 °C
- 30,900 BTU/h
- SEER2
- 16.0
- HSPF2 (region IV)
- 9.0
- AHRI
- 215318893
- ENERGY STAR Canada
- 3560730
- Indicative LogisVert
- $5,400
D5CUHA + D5FUHA
D5CUHAH60AAK + D5FUHAH60XAK- Rated heat at -8 °C
- 45,000 BTU/h
- Maximum at -15 °C
- 54,000 BTU/h
- Maximum at -30 °C
- 37,300 BTU/h
- SEER2
- 17.5
- HSPF2 (region IV)
- 9.5
- AHRI
- 215318894
- ENERGY STAR Canada
- 3560731
- Indicative LogisVert
- $5,400
DLCURA + DLFUAA
DLCURAH60ABK + DLFUAAH60XAK- Rated heat at -8 °C
- 42,000 BTU/h
- Maximum at -15 °C
- 48,500 BTU/h
- Maximum at -30 °C
- 29,900 BTU/h
- SEER2
- 15.3
- HSPF2 (region IV)
- 9.4
- AHRI
- 210025741
- ENERGY STAR Canada
- 2465396
- Indicative LogisVert
- $5,040
The other central units on this page (R4H5S, N4H5S, H4H5S, H4H7T, HCH6, HSH6 and HSH4) are neither on NEEP’s cold-climate list nor in the ENERGY STAR Canada data, so we publish no cold-weather heat figures for them.
All 53 ARCOAIRE central systems, right below.
The 18 cold-climate certified systems carry their AHRI number and an indicative LogisVert amount. Pricing by quote.
Eighteen systems, one AHRI number each.
Heat in BTU/h. Our indicative LogisVert amounts are based on the rated value at -8 °C; the maximums at -15 and -30 °C show what the system can deliver in deep cold.
| Size | AHRI | Rated at -8 °C | Max. at -15 °C | Max. at -30 °C | SEER2 / HSPF2 | Indicative LogisVert | |
|---|---|---|---|---|---|---|---|
| D5CUHA (R-454B) with the D5FUAA indoor unit | |||||||
| 1.5 tons D5CUHAH18AAK + D5FUAAH18XAK | 215318887 | 15,000 | 18,000 | 12,000 | 19.0 / 9.8 | $1,800 | |
| 2 tons D5CUHAH24AAK + D5FUAAH24XAK | 215318888 | 20,800 | 21,600 | 12,000 | 18.4 / 10.0 | $2,496 | |
| 2.5 tons D5CUHAH30AAK + D5FUAAH30XAK | 215318890 | 23,800 | 32,600 | 20,100 | 16.9 / 10.0 | $2,856 | |
| 3 tons D5CUHAH36AAK + D5FUAAH36XAK | 215318891 | 31,800 | 39,000 | 27,800 | 17.4 / 10.3 | $3,816 | |
| 4 tons D5CUHAH48AAK + D5FUAAH48XAK | 215318892 | 39,500 | 46,000 | 25,900 | 16.5 / 9.5 | $4,740 | |
| 5 tons D5CUHAH60AAK + D5FUAAH60XAK | 215318893 | 45,000 | 52,000 | 30,900 | 16.0 / 9.0 | $5,400 | |
| D5CUHA (R-454B) with the D5FUHA indoor unit | |||||||
| 1.5 tons D5CUHAH18AAK + D5FUHAH24XAK | 215318901 | 14,700 | 18,600 | 11,800 | 19.0 / 10.2 | $1,764 | |
| 2 tons D5CUHAH24AAK + D5FUHAH24XAK | 215318889 | 20,800 | 20,600 | 12,100 | 18.7 / 10.0 | $2,496 | |
| 2.5 tons D5CUHAH30AAK + D5FUHAH36XAK | 215318902 | 24,000 | 33,200 | 17,900 | 17.2 / 10.8 | $2,880 | |
| 3 tons D5CUHAH36AAK + D5FUHAH36XAK | 215323725 | 33,000 | 37,400 | 27,600 | 18.0 / 10.0 | $3,960 | |
| 4 tons D5CUHAH48AAK + D5FUHAH60XAK | 215318903 | 39,500 | 48,000 | 27,200 | 17.5 / 9.5 | $4,740 | |
| 5 tons D5CUHAH60AAK + D5FUHAH60XAK | 215318894 | 45,000 | 54,000 | 37,300 | 17.5 / 9.5 | $5,400 | |
| High-heat DLCURA (R-410A) with the DLFUAA indoor unit | |||||||
| 1.5 tons DLCURAH18ABK + DLFUAAH18XAK | 209852036 | 13,500 | 16,500 | 10,500 | 18.0 / 9.3 | $1,620 | |
| 2 tons DLCURAH24ABK + DLFUAAH24XAK | 209852037 | 19,200 | 22,600 | 13,400 | 17.4 / 10.0 | $2,304 | |
| 2.5 tons DLCURAH30ABK + DLFUAAH30XAK | 209852044 | 21,000 | 24,000 | 13,700 | 16.2 / 8.9 | $2,520 | |
| 3 tons DLCURAH36ABK + DLFUAAH36XAK | 209852043 | 30,400 | 34,400 | 21,500 | 16.0 / 9.5 | $3,648 | |
| 4 tons DLCURAH48ABK + DLFUAAH48XAK | 209852039 | 36,000 | 46,000 | 24,500 | 15.6 / 9.4 | $4,320 | |
| 5 tons DLCURAH60ABK + DLFUAAH60XAK | 210025741 | 42,000 | 48,500 | 29,900 | 15.3 / 9.4 | $5,040 | |
NEEP cold-climate list, records modified August 24, 2026 and read October 28, 2026 (HSPF2 in region IV). ENERGY STAR Canada for the certification numbers. LogisVert: indicative amounts from our product sheets.
Two families certified for deep cold, five conventional ones.
What the brand writes about each one, with the page of its document.
D5CUHA
The QuietComfort® Crossover heat pump of brochure DLS-045: variable-speed compressor, runs from -30 to 50 °C, up to 19.0 SEER2 and 10.8 HSPF2. It “maintains the characteristics of traditional ducted heating and cooling while leveraging elements of ductless technology”.
12 products on our site · DLS-045-AR-00, April 2025, pp. 2 and 3
High-heat DLCURA
Variable-speed rotary compressor. The B in the model (DLCURAH…ABK) marks the high-heat version: heating down to -30 °C. Crankcase and base-pan heaters are standard on every size.
6 products on our site · DLCURA31-01PD, edition 09/22, pp. 1 to 3 and 82
R4H5S
The entry line: in the model code, the R stands for “Entry”. Single-stage scroll compressor; heats down to an outdoor temperature of -23.3 °C (-10 °F).
7 products on our site · R4H5S-01PD, edition 09/22, pp. 2 and 18
N4H5S
Performance Series, single stage. The scroll compressor sits in an extra-thick shell, behind a hail-guard grille.
7 products on our site · HP-003-AR-00, 12/2022, pp. 2 to 4
H4H5S
Ion™ System, single stage, with a compressor sound jacket and compatibility with the communicating Ion control.
7 products on our site · HP-002-AR-00, 01/2023, pp. 2 to 4
H4H7T
Two-stage Ion™ System: the compressor is designed to run most of the time at the quieter low stage and, in cooling, switches to high stage as it gets warmer.
4 products on our site · HP-002-AR-00, 01/2023, pp. 3 and 4
HCH6 · HSH6 · HSH4
Lines rated before the SEER2 standard (SEER and HSPF ratings). The brand ranks the two-stage HCH6 above the single-stage HSH6 and HSH4.
10 products on our site · 42832540504, 09/2017, pp. 3 and 4; 428 32 5409 00, 5/2020
The same 3-ton DLCURA, three AHRI numbers: it all depends on the unit in the basement.
Here the DLCURA is paired with the DLFUAA air handler, which replaces the furnace. On the Add-on page it goes with a DLFULA coil on top of the furnace you keep.
| System | AHRI | Rated at -8 °C | Max. at -15 °C | Max. at -30 °C | Indicative LogisVert |
|---|---|---|---|---|---|
| DLCURA + DLFUAA indoor unit this page | 209852043 | 30,400 | 34,400 | 21,500 | $3,648 |
| DLCURA + DLFULA coil, 21 in Add-on | 213372121 | 33,000 | 32,000 | 24,000 | $3,960 |
| DLCURA + DLFULA coil, 17.5 in Add-on | 213372120 | 27,400 | 31,600 | 20,000 | $3,288 |
NEEP, read October 28, 2026. Coil width as given on our product sheets. Indicative LogisVert amounts.
Three details from the ARCOAIRE documents that change an install.
One D5FUHA indoor unit covers two capacities.
The D5FUHAH36XAK serves both the 2.5 and the 3 ton: the capacity is set on its control board. Same for the 24 (1.5 and 2 tons) and the 60 (4 and 5 tons).
D5FUHA31-01PD, ed. 03/25, pp. 4, 8 and 27The D5FUHA adjusts its fan to your ducts.
Its “Computational Constant Airflow” adapts fan speed to the existing ducts, a dirty filter or a blocked coil, even with no call for heating or cooling.
D5FUHA31-01PD, ed. 03/25, p. 2Up to 213 ft (65 m) of refrigerant line for the DLCURA.
The factory charge and the published capacities are based on 25 ft (7.6 m); beyond that the installer adds 0.69 oz of refrigerant per foot (65 g/m). Useful when the outdoor unit must sit far from the basement.
DLCURA31-01PD, ed. 09/22, pp. 1 and 82What people ask us about ARCOAIRE central systems.
D5CUHA or DLCURA: which heats better at -30 °C?
It depends on the size. At 3 tons the D5CUHA still delivers 27,800 BTU/h with the D5FUAA indoor unit, against 21,500 BTU/h for the DLCURA. At 2 tons it is the other way around: 13,400 for the DLCURA, 12,000 and 12,100 for the D5CUHA. These are the maximums listed by NEEP at -22 °F.
Why two products for the same D5CUHA?
Because it pairs with two indoor units, the D5FUAA or the D5FUHA, and each pairing has its own AHRI number and figures. At 2.5 tons, for example: HSPF2 of 10.0 with the D5FUAA and 10.8 with the D5FUHA; indicative LogisVert amounts of $2,856 and $2,880.
Do the R4H5S, N4H5S, H4H5S and H4H7T qualify for LogisVert?
Our product sheets show no amount for them, and they are neither on NEEP’s cold-climate list nor in the ENERGY STAR Canada data read October 28, 2026. Only Hydro-Québec confirms eligibility and the amount granted.
I have a gas or oil furnace. Do I keep it?
It can be. The Add-on page shows the systems that go on top of an existing furnace, with a coil; whether your furnace is compatible is checked at the visit. Gas and oil work is done by a licensed partner.
How do you choose the size?
At the visit. We look at the house, the ducts, the insulation and the electrical panel, then propose the system that fits, with its AHRI number when it has one.
Where does the outdoor unit go?
For the DLCURA, the manufacturer lists clearances of 24 in and 4 in depending on the side, and asks for the unit to sit at least 2 in (50 mm) above the deepest expected snow.
Is this the LogisVert amount I will get?
No. It is an indicative amount from our product sheets. Only Hydro-Québec confirms the amount granted, when you apply.
Your ARCOAIRE central system, chosen at your home, installed by AirGreen.
We come out to look at your ductwork, your basement and your electrical panel. You get a quote for a specific system, with its AHRI number when it has one and the indicative LogisVert amount where it applies.
Sources checked on October 28, 2026
- NEEP cold-climate heat pump list (ashp.neep.org), records 391438, 391764, 391765, 391766, 391773, 391774, 391775, 391776, 391777, 391778, 391779, 391780, 399251, 399252, 403229, 403444, 403445, 403448, 403450, 403451, modified August 24, 2026, read October 28, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market, read October 28, 2026.
- ARCOAIRE, brochure DLS-045-AR-00 (April 2025) and its French edition, pp. 2 to 4.
- ARCOAIRE, Product Data DLCURA31-01PD (edition 09/22), pp. 1 to 3, 8 and 82.
- ARCOAIRE, Product Data D5FUHA31-01PD (edition 03/25), pp. 2, 4, 8 and 27.
- ARCOAIRE, Product Data R4H5S-01PD (edition 09/22), pp. 2 and 18; brochures HP-002-AR-00 (01/2023), HP-003-AR-00 (12/2022), 42832540504 (09/2017) and 428 32 5409 00 (5/2020).
- airgreen.ca product sheets (AHRI numbers, indicative LogisVert amounts), re-read October 28, 2026.
LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.