Gree Electric Heat Element for FLEXX R32 Air Handler Cabinet

In stock

The genuine Gree electric heater that adds backup heat to the air handler of your FLEXX R32 central heat pump.

AirGreen codeAG-AC-01801

6 to 20 kWsix sizes
240 Vrated output
Breakerbuilt into the kit
R-32FLEXX R32Genuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-01801
BrandGree
Part nos.LYQ-08-F, LYQ-08-G, LYQ-08-H, 21-4216-03, 21-4217-01, 21-4228-01
ForFLEXX ULTRA R32 and FLEXX ECO R32 air handlers
MountingInside the cabinet, through the front and upper access panels
ComponentsBreaker, relay, thermal protection

The Gree electric heat element for the FLEXX R32 air handler cabinet is the original backup heat for the FLEXX ULTRA R32 and FLEXX ECO R32 central heat pumps. It installs in the cabinet, through the access panels, and heats the air when the central heat pump can no longer keep up, during a defrost or as emergency heat.

Backup heat designed for Québec winters

In extreme cold, a heat pump loses capacity. The element closes the gap without changing equipment. Gree offers it in 6, 9, 10, 12, 15 and 20 kW (rated output at 240 V). Each element has its own built-in breaker. Gree describes the LYQ-08 models with a nickel-chrome element on ceramic modules, a thermal fuse, a temperature controller, a relay and a 30, 45 or 60 A breaker.

The right element for your cabinet

  • LYQ-08-F (6 kW): all FLEXX R32 cabinets, single power supply.
  • LYQ-08-G (9 kW) and 21-4216-03 (10 kW): from 24,000 BTU/h.
  • LYQ-08-H (12 kW) and 21-4217-01 (15 kW): from 36,000 BTU/h, and FLEXX ECO 30,000 BTU/h.
  • 21-4228-01 (20 kW): from 36,000 BTU/h.

Wiring

According to Gree’s sheet, the 9 and 12 kW elements require two power supplies. Each element needs a circuit sized according to Gree’s data and the electrical code. Shut off all power sources before opening the cabinet. Send us your cabinet’s model number: we confirm the element before ordering.

Installed by AirGreen across Greater Montréal

We install Gree central heat pumps and their backup heat elements, with a master electrician for the wiring, in Montréal, Laval, Longueuil, the South Shore and the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with your cabinet model and the output you need.

01 · What it is for

Backup electric heat for deep cold

The heater sits in the FLEXX air handler and heats the air when the heat pump can no longer keep up.

  • Backup heat for a FLEXX R32 central heat pump
  • Emergency heat during defrost or an outdoor unit failure
  • Replacing a damaged heater with the same output
  • Adding backup heat to an air handler installed without one
Genuine Gree partThe heaters Gree specifies for its FLEXX R32 air handlers, with their compatibility grid.
Built to lastGree describes the LYQ-08 heaters with a nickel-chrome element on ceramic modules, a thermal fuse and a temperature limit.
Sized to the cabinetThe bigger the air handler, the larger the heater it accepts.
Compatible with
FXU12HP230V1R32AHFXU18HP230V1R32AHFXU24HP230V1R32AHFXU36HP230V1R32AHFXU48HP230V1R32AHFXU60HP230V1R32AHFXE24HP230V1R32AHFXE30HP230V1R32AHFXE36HP230V1R32AHFXE48HP230V1R32AHFXE60HP230V1R32AH
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

6 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelPart no.Rated output (240 V)Allowed FLEXX R32 air handlersAirGreen code
6 kW – LYQ-08-FLYQ-08-F6 kWFXU12 to FXU60, FXE24 to FXE60AG-AC-01801
9 kW – LYQ-08-GLYQ-08-G9 kWFXU24 to FXU60, FXE24 to FXE60AG-AC-01802
10 kW – 21-4216-0321-4216-0310 kWFXU24 to FXU60, FXE24 to FXE60AG-AC-01803
12 kW – LYQ-08-HLYQ-08-H12 kWFXU36 to FXU60, FXE30 to FXE60AG-AC-01804
15 kW – 21-4217-0121-4217-0115 kWFXU36 to FXU60, FXE30 to FXE60AG-AC-01805
20 kW – 21-4228-0121-4228-0120 kWFXU36 to FXU60, FXE36 to FXE60AG-AC-01806

Rated output at 240 V. The air handler size limits the heater you can use.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandGree
TypeAuxiliary electric heater for air handler
RangeFLEXX ULTRA R32 and FLEXX ECO R32
Outputs6, 9, 10, 12, 15 and 20 kW (at 240 V)
Components (LYQ-08)Mounting plate, thermal fuse, temperature limit, Cr20Ni80 element on ceramic modules, relay, circuit breaker
Built-in breaker30 A, 45 A or 60 A depending on the heater
Compatible air handlersFXU12 to FXU60, FXE24 to FXE60 (by output)
Part no.LYQ-08-F
Rated output (240 V)6 kW
Allowed FLEXX R32 air handlersFXU12 to FXU60, FXE24 to FXE60
AirGreen codeAG-AC-01801
04 · Before installing

What to know before installing

  • Check Gree’s grid: 6 kW on every air handler, 9 and 10 kW from 24,000 Btu/h, 12 and 15 kW on the larger cabinets, 20 kW from 36,000 Btu/h.
  • Per Gree’s submittal, the 9 and 12 kW heaters need two power supplies.
  • Disconnect every power source before opening the cabinet.
  • The electrical connection is a job for a licensed electrician.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which heater fits my FLEXX air handler?

Per Gree’s compatibility grid: 6 kW on every FLEXX R32 air handler, 9 and 10 kW from 24,000 Btu/h, 12 and 15 kW from 36,000 Btu/h (and on the 30,000 Btu/h FLEXX ECO), 20 kW from 36,000 Btu/h. Send us your air handler model number and we confirm before ordering.

What is the difference between LYQ-08 and 21-42…?

They are two heater families Gree documents for FLEXX R32 air handlers. LYQ-08 covers 6, 9 and 12 kW; 21-4216-03, 21-4217-01 and 21-4228-01 cover 10, 15 and 20 kW.

Do I need a new supply at the panel?

Yes, the heater needs a circuit sized per Gree’s sheet and the code. The 9 and 12 kW heaters have two supplies. We do the calculation with a licensed electrician.

Can you install it?

Yes. We fit the heater in the air handler and coordinate the connection with a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Add backup heat to your FLEXX air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.