Hitachi 8HK Electric Heating Element for airCore 700 Air Handler

In stock

The manufacturer’s electric backup heat for the JPE air handlers of the airCore 700 central heat pump.

AirGreen codeAG-AC-00705

2 to 20 kWsingle-phase kits
8HK seriesthe only one allowed in the JPE
Field installedfits inside the air handler
airCore 700Genuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-00705
BrandHitachi
Part no.8HK (by kW rating)
ForairCore 700 JPE air handlers
Power208/230 V, single phase

The 8HK electric heating element is the backup heat Hitachi specifies for the JPE air handlers of the airCore 700 central heat pump. It is installed on site, inside the air handler, and supplies supplemental or emergency heat when the heat pump is no longer enough.

The electric complement to a central heat pump

The JPE air handler installation manual is clear: if the unit is to receive electric heat, use only the 8HK elements listed on its nameplate. Single-phase elements range from 2 to 20 kW. Once the element is installed, its model is written on the air handler's nameplate.

Which output for which air handler?

  • JPE18B3XB2HS1A: 2, 5, 8 or 10 kW
  • JPE24B3XC2HS1A: 2, 5, 8, 10 or 15 kW
  • JPE30B3XD2HS1A and JPE36B3XD2HS1A: 2, 5, 8, 10, 15 or 20 kW

For each combination, the airCore 700 technical catalogue gives the element amperage at 240 V, the minimum circuit ampacity and the maximum overcurrent protection. We start from these values and from the home's heat loss calculation.

Installation points

In some horizontal installations, the element's disconnect must be rotated 180° so that the up position corresponds to on, as required by the UL 60335-2-40 standard. For the 15 and 20 kW elements, the manual shows two-circuit power supply diagrams. Connections are made with copper conductors, by qualified personnel.

Installed by AirGreen in Greater Montréal

We install the 8HK element and commission the airCore 700 heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with your air handler model and the output you want.

01 · What it is for

Backup heat for your airCore 700

The heat kit takes over or adds to the heat pump when the cold gets too deep.

  • airCore 700 JPE18, JPE24, JPE30 and JPE36 air handlers
  • Supplementary heat during extreme cold
  • Emergency heat if the heat pump is off
  • Replacing an existing 8HK kit
Required seriesThe JPE manual calls for 8HK kits only, as listed on the air handler nameplate.
Field installedThe kit is a field-installed accessory that goes inside the air handler.
Published electrical dataThe technical catalog lists minimum circuit ampacity and maximum overcurrent protection for each air handler.
Compatible with
JPE18B3XB2HS1AJPE24B3XC2HS1AJPE30B3XD2HS1AJPE36B3XD2HS1A
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

6 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelPart no.Heater amps at 240 VApproved JPE air handlersAirGreen code
2 kW – 8HK065002068HK0650020610.0 AJPE18, JPE24, JPE30, JPE36AG-AC-00701
5 kW – 8HK065005068HK0650050620.0 AJPE18, JPE24, JPE30, JPE36AG-AC-00702
8 kW – 8HK065008068HK0650080632.1 AJPE18, JPE24, JPE30, JPE36AG-AC-00703
10 kW – 8HK065010068HK0650100640.0 AJPE18, JPE24, JPE30, JPE36AG-AC-00704
15 kW – 8HK265015068HK2650150660.0 AJPE24, JPE30, JPE36AG-AC-00705
20 kW – 8HK265020068HK2650200680.0 AJPE30, JPE36AG-AC-00706

Nominal kit rating. Amperage and approved air handlers show for each model.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandHitachi
Series8HK, field installed
Ratings2, 5, 8, 10, 15 and 20 kW
Power208/230 V, single phase
Air handlersairCore 700 JPE18B3XB2HS1A, JPE24B3XC2HS1A, JPE30B3XD2HS1A, JPE36B3XD2HS1A
ConductorsCopper only
Part no.8HK26501506
Heater amps at 240 V60.0 A
Approved JPE air handlersJPE24, JPE30, JPE36
AirGreen codeAG-AC-00705
04 · Before installing

What to know before installing

  • Size the kit from the heat-loss calculation and the air handler: 15 and 20 kW do not fit every JPE.
  • After installation, mark the installed kit on the air handler nameplate.
  • In some horizontal installs the kit’s service disconnect must be rotated 180° (UL 60335-2-40 requirement).
  • For 15 and 20 kW kits, the air handler manual shows two-circuit power layouts: follow the one that fits your installation.
  • Copper conductors only, connected by a licensed electrician or qualified technician.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which rating do I need?

It depends on the home’s heat loss and on the air handler. The JPE18 takes 2 to 10 kW, the JPE24 up to 15 kW, the JPE30 and JPE36 up to 20 kW. We run the numbers with you.

Can I use a kit from another series?

No. The JPE manual says to use only the 8HK kits listed on its nameplate.

Does the electrical panel need work?

Often, yes: the kit needs its own circuit, sized from the manufacturer’s table for your air handler. An electrician checks the panel capacity.

Can you install it?

Yes. We fit the kit in the air handler and commission it with the heat pump, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

An airCore 700 ready for a Québec winter

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom