Arcoaire EHKMC Electric Heater Kit for D5FUAA Air Handler
Genuine electric auxiliary heat for D5FUAA air handlers, from 5 to 25 kW.
AirGreen codeAG-AC-13702
514 316-2973 · sales@airgreen.ca
Quick facts
EHKMC electric heater kits are the auxiliary heat for D5FUAA air handlers, from 18,000 to 60,000 BTU/h. Installed in the air handler, the kit tops up the central heat pump when it needs extra heat. Six outputs are available, from 5 to 25 kW, at 208/230 V, with built-in circuit breakers.
The right output for each air handler size
The manufacturer publishes a selection table: each output is allowed with certain air handler sizes only.
- 5 kW: 18K to 36K
- 8 kW: 18K to 48K
- 10 kW: 18K to 60K
- 15 kW: 24K to 60K
- 20 kW: 36K to 60K
- 25 kW: 60K only
Circuits and power supply
The 5, 8 and 10 kW kits connect to one circuit. The 15 and 20 kW kits need two, and the 25 kW three, each with its own MCA and maximum protection. The D5FUAA product data states the air handlers are not equipped for a single-point electrical connection with electric heat: a separate power supply is required. The values for each output appear in the table when you select it. Have your electrical service checked before choosing a high output.
Installed by AirGreen in Greater Montréal
We install the kit in your air handler and set up the auxiliary heat with the heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore; the supply circuit is done by a licensed electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the air handler model, the output and the quantity.
Auxiliary heat for the D5FUAA air handler
In the air handler, the kit tops up the central heat pump when it needs extra heat.
- Auxiliary heat for a central heat pump with a D5FUAA air handler
- Homes heated electrically through ductwork
- Adding backup heat to an existing D5FUAA air handler
- Replacing an EHKMC kit
6 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Model | Circuits / breakers | Current per circuit at 208 / 230 V | MCA per circuit at 208 / 230 V | Max. protection (MOP) per circuit at 208 / 230 V | Relays | Dimensions (H × W × D) | Net weight | Air handler sizes listed | Part no. | AirGreen code |
|---|---|---|---|---|---|---|---|---|---|---|
| 5 kW – EHKMC05KN | 1 / 1 | 18.0 / 20.0 A | 23.0 / 27.0 A | 25 / 30 A | 1 | 8.03 × 21.06 × 10.16 in | 2.6 kg (5.73 lb) | 18K, 24K, 30K, 36K | EHKMC05KN | AG-AC-13701 |
| 8 kW – EHKMC08KN | 1 / 1 | 28.8 / 32.0 A | 37.0 / 42.0 A | 40 / 45 A | 2 | 8.03 × 21.06 × 10.16 in | 3.3 kg (7.28 lb) | 18K, 24K, 30K, 36K, 48K | EHKMC08KN | AG-AC-13702 |
| 10 kW – EHKMC10KN | 1 / 1 | 36.0 / 40.0 A | 46.0 / 53.0 A | 50 / 60 A | 2 | 8.03 × 21.06 × 10.16 in | 3.1 kg (6.83 lb) | 18K, 24K, 30K, 36K, 48K, 60K | EHKMC10KN | AG-AC-13703 |
| 15 kW – EHKMC15KN | 2 / 2 | 18.0 / 20.0 A + 36.0 / 40.0 A | 23.0 / 27.0 A + 46.0 / 53.0 A | 25 / 30 A + 50 / 60 A | 3 | 8.03 × 21.06 × 10.16 in | 4.0 kg (8.82 lb) | 24K, 30K, 36K, 48K, 60K | EHKMC15KN | AG-AC-13704 |
| 20 kW – EHKMC20KN | 2 / 2 | 36.0 / 40.0 A + 36.0 / 40.0 A | 46.0 / 53.0 A + 46.0 / 53.0 A | 50 / 60 A + 50 / 60 A | 4 | 8.03 × 21.06 × 10.16 in | 4.4 kg (9.70 lb) | 36K, 48K, 60K | EHKMC20KN | AG-AC-13705 |
| 25 kW – EHKMC25KN | 3 / 3 | 18.0 / 20.0 A + 36.0 / 40.0 A + 36.0 / 40.0 A | 23.0 / 27.0 A + 46.0 / 53.0 A + 46.0 / 53.0 A | 25 / 30 A + 50 / 60 A + 50 / 60 A | 5 | 8.03 × 21.06 × 11.81 in | 5.7 kg (12.57 lb) | 60K | EHKMC25KN | AG-AC-13706 |
Nominal output. Circuits, electrical values and allowed air handler sizes are in the table for the model you pick.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Each output is listed for certain air handler sizes only: check the “Air handler sizes listed” row of the model you pick.
- The 15 and 20 kW kits have 2 supply circuits and the 25 kW has 3, each with its own protection.
- A separate power supply is required: the air handler is not equipped for a single-point connection with electric heat.
- The supply circuit is done by a licensed electrician, with the unit powered off.
Manufacturer documents
You may also need
Copper Electrical Wire
Fujitsu Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)
Hitachi Port Adapter for airHome RAM-G Multi-Zone
Hitachi PSC-6RAD H-Link Adapter for airHome Indoor Unit
Hitachi SPX-RAMHLK H-Link Adapter for airHome Multi-Zone Outdoor Unit
Hitachi 5-Wire Thermostat, Wi-Fi and BACnet/Modbus Adapter – C4STAT01Original partsSee all
Frequently asked questions
Which kit fits my air handler?
Per the manufacturer’s table: 5 kW from 18K to 36K, 8 kW up to 48K, 10 kW from 18K to 60K, 15 kW from 24K to 60K, 20 kW from 36K to 60K and 25 kW for the 60K only. We pick the output from a heating load calculation.
How many circuits do I need?
One for the 5, 8 and 10 kW kits, two for the 15 and 20 kW and three for the 25 kW, each with its own MCA and maximum protection.
Do these kits fit a DLFUAA air handler?
The manufacturer’s DLFUAA product data we checked lists a different kit series. Send us your air handler model number and we confirm before ordering.
Can you install it?
Yes. We fit the kit in the air handler and set up the auxiliary heat with the heat pump; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.
Genuine auxiliary heat for your D5FUAA air handler
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.