Arcoaire EHKMC Electric Heater Kit for D5FUAA Air Handler

In stock

Genuine electric auxiliary heat for D5FUAA air handlers, from 5 to 25 kW.

AirGreen codeAG-AC-13706

5 to 25 kWsix kits
1 to 3 circuitsdepending on output
208/230 Vseparate power supply
Central heat pumpGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-13706
BrandArcoaire
Part no.EHKMC05KN to EHKMC25KN
ForD5FUAAH18XAK to D5FUAAH60XAK air handlers
Power supply208/230 V
ProtectionBuilt-in circuit breakers

EHKMC electric heater kits are the auxiliary heat for D5FUAA air handlers, from 18,000 to 60,000 BTU/h. Installed in the air handler, the kit tops up the central heat pump when it needs extra heat. Six outputs are available, from 5 to 25 kW, at 208/230 V, with built-in circuit breakers.

The right output for each air handler size

The manufacturer publishes a selection table: each output is allowed with certain air handler sizes only.

  • 5 kW: 18K to 36K
  • 8 kW: 18K to 48K
  • 10 kW: 18K to 60K
  • 15 kW: 24K to 60K
  • 20 kW: 36K to 60K
  • 25 kW: 60K only

Circuits and power supply

The 5, 8 and 10 kW kits connect to one circuit. The 15 and 20 kW kits need two, and the 25 kW three, each with its own MCA and maximum protection. The D5FUAA product data states the air handlers are not equipped for a single-point electrical connection with electric heat: a separate power supply is required. The values for each output appear in the table when you select it. Have your electrical service checked before choosing a high output.

Installed by AirGreen in Greater Montréal

We install the kit in your air handler and set up the auxiliary heat with the heat pump in Montréal, Laval, Longueuil, on the South Shore and on the North Shore; the supply circuit is done by a licensed electrician. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the air handler model, the output and the quantity.

01 · What it is for

Auxiliary heat for the D5FUAA air handler

In the air handler, the kit tops up the central heat pump when it needs extra heat.

  • Auxiliary heat for a central heat pump with a D5FUAA air handler
  • Homes heated electrically through ductwork
  • Adding backup heat to an existing D5FUAA air handler
  • Replacing an EHKMC kit
Six outputsFrom 5 to 25 kW, each listed for specific air handler sizes.
Built-in breakers1 to 3 circuit breakers depending on output, one per circuit.
Separate power supplyThe D5FUAA air handler does not take a single-point connection with electric heat.
Compatible with
D5FUAAH18XAKD5FUAAH24XAKD5FUAAH30XAKD5FUAAH36XAKD5FUAAH48XAKD5FUAAH60XAK
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

6 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelCircuits / breakersCurrent per circuit at 208 / 230 VMCA per circuit at 208 / 230 VMax. protection (MOP) per circuit at 208 / 230 VRelaysDimensions (H × W × D)Net weightAir handler sizes listedPart no.AirGreen code
5 kW – EHKMC05KN1 / 118.0 / 20.0 A23.0 / 27.0 A25 / 30 A18.03 × 21.06 × 10.16 in2.6 kg (5.73 lb)18K, 24K, 30K, 36KEHKMC05KNAG-AC-13701
8 kW – EHKMC08KN1 / 128.8 / 32.0 A37.0 / 42.0 A40 / 45 A28.03 × 21.06 × 10.16 in3.3 kg (7.28 lb)18K, 24K, 30K, 36K, 48KEHKMC08KNAG-AC-13702
10 kW – EHKMC10KN1 / 136.0 / 40.0 A46.0 / 53.0 A50 / 60 A28.03 × 21.06 × 10.16 in3.1 kg (6.83 lb)18K, 24K, 30K, 36K, 48K, 60KEHKMC10KNAG-AC-13703
15 kW – EHKMC15KN2 / 218.0 / 20.0 A + 36.0 / 40.0 A23.0 / 27.0 A + 46.0 / 53.0 A25 / 30 A + 50 / 60 A38.03 × 21.06 × 10.16 in4.0 kg (8.82 lb)24K, 30K, 36K, 48K, 60KEHKMC15KNAG-AC-13704
20 kW – EHKMC20KN2 / 236.0 / 40.0 A + 36.0 / 40.0 A46.0 / 53.0 A + 46.0 / 53.0 A50 / 60 A + 50 / 60 A48.03 × 21.06 × 10.16 in4.4 kg (9.70 lb)36K, 48K, 60KEHKMC20KNAG-AC-13705
25 kW – EHKMC25KN3 / 318.0 / 20.0 A + 36.0 / 40.0 A + 36.0 / 40.0 A23.0 / 27.0 A + 46.0 / 53.0 A + 46.0 / 53.0 A25 / 30 A + 50 / 60 A + 50 / 60 A58.03 × 21.06 × 11.81 in5.7 kg (12.57 lb)60KEHKMC25KNAG-AC-13706

Nominal output. Circuits, electrical values and allowed air handler sizes are in the table for the model you pick.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandArcoaire
TypeAuxiliary electric heater kit for air handler
SeriesEHKMC
ModelsEHKMC05KN, EHKMC08KN, EHKMC10KN, EHKMC15KN, EHKMC20KN, EHKMC25KN
Power supply208/230 V
Built-in protectionCircuit breakers
Air handlersD5FUAAH18XAK, D5FUAAH24XAK, D5FUAAH30XAK, D5FUAAH36XAK, D5FUAAH48XAK, D5FUAAH60XAK
Circuits / breakers3 / 3
Current per circuit at 208 / 230 V18.0 / 20.0 A + 36.0 / 40.0 A + 36.0 / 40.0 A
MCA per circuit at 208 / 230 V23.0 / 27.0 A + 46.0 / 53.0 A + 46.0 / 53.0 A
Max. protection (MOP) per circuit at 208 / 230 V25 / 30 A + 50 / 60 A + 50 / 60 A
Relays5
Dimensions (H × W × D)8.03 × 21.06 × 11.81 in
Net weight5.7 kg (12.57 lb)
Air handler sizes listed60K
Part no.EHKMC25KN
AirGreen codeAG-AC-13706
04 · Before installing

What to know before installing

  • Each output is listed for certain air handler sizes only: check the “Air handler sizes listed” row of the model you pick.
  • The 15 and 20 kW kits have 2 supply circuits and the 25 kW has 3, each with its own protection.
  • A separate power supply is required: the air handler is not equipped for a single-point connection with electric heat.
  • The supply circuit is done by a licensed electrician, with the unit powered off.
05 · Documents

Manufacturer documents

06 · Goes with

You may also need

Same category
Original parts
See all
07 · Questions

Frequently asked questions

Which kit fits my air handler?

Per the manufacturer’s table: 5 kW from 18K to 36K, 8 kW up to 48K, 10 kW from 18K to 60K, 15 kW from 24K to 60K, 20 kW from 36K to 60K and 25 kW for the 60K only. We pick the output from a heating load calculation.

How many circuits do I need?

One for the 5, 8 and 10 kW kits, two for the 15 and 20 kW and three for the 25 kW, each with its own MCA and maximum protection.

Do these kits fit a DLFUAA air handler?

The manufacturer’s DLFUAA product data we checked lists a different kit series. Send us your air handler model number and we confirm before ordering.

Can you install it?

Yes. We fit the kit in the air handler and set up the auxiliary heat with the heat pump; the supply circuit is run by a licensed electrician, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Genuine auxiliary heat for your D5FUAA air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.