Fujitsu Long Life Filter for Medium Static Pressure Ducted Unit

In stock

The genuine long-life filter for Fujitsu medium static pressure ducted units, in three sizes by capacity.

AirGreen codeAG-AC-00502

3 sizesby capacity
12 to 48,000 BTUARUH ducted units
Genuine partFujitsu
Ducted unitGenuine part
Model
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-00502
BrandFujitsu
Part no.UTD-LFNA, UTD-LFNB, UTD-LFNC
Fujitsu nameLong Life Filter
ForARUH…KUAS and ARU…RGLX ducted units

The Fujitsu long life filter is the filtration option Fujitsu offers for its medium static pressure ducted units, the R-32 ARUH…KUAS models and the previous ARU…RGLX generation. It traps dust before it reaches the coil and the fan.

Three sizes, based on the unit’s capacity

A ducted unit is hidden in a ceiling or an attic and distributes air through ducts to several rooms. Its filter therefore works for the whole zone it serves. Fujitsu matches each size to a capacity group, shown in its units’ submittal sheets.

Matching specified by Fujitsu

  • UTD-LFNC: 12,000 BTU units (ARUH12KUAS, ARU12RGLX)
  • UTD-LFNB: 18,000 to 30,000 BTU units (ARUH18KUAS, ARUH24KUAS, ARUH30KUAS)
  • UTD-LFNA: 36,000 to 48,000 BTU units (ARUH36KUAS, ARUH42KUAS, ARUH48KUAS)

Maintenance

A clogged filter reduces airflow, and with it the comfort and efficiency of the heat pump. Check it at least at every change of season, and cut power to the unit before opening it. On a ducted unit installed in a hard-to-reach spot, we can include it in the annual maintenance.

Installed by AirGreen across Greater Montréal

We install and maintain Fujitsu ducted units in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the indoor unit model number and the quantity.

01 · What it is for

The filter made for your ducted unit

Fujitsu offers this filter as an option for its medium static ducted units, with one size per capacity group.

  • Fujitsu AIRSTAGE ARUH12KUAS to ARUH48KUAS ducted units (R-32)
  • ARU12RGLX to ARU48RGLX ducted units
  • Replacing a worn Fujitsu long-life filter
  • Adding the optional filter at installation
Size by capacityLFNC for 12,000 BTU, LFNB for 18 to 30,000, LFNA for 36 to 48,000.
Listed by FujitsuShown on the submittal sheets of the ARUH ducted units.
Genuine partThe filter Fujitsu pairs with these units.
Compatible with
ARUH12KUASARUH18KUASARUH24KUASARUH30KUASARUH36KUASARUH42KUASARUH48KUASARU12RGLXARU18RGLXARU24RGLXARU30RGLXARU36RGLXARU42RGLXARU48RGLX
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

3 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModelUnit capacityUnits listed by FujitsuPart no.AirGreen code
UTD-LFNA – 36,000 to 48,000 BTU36,000, 42,000 and 48,000 BTUARUH36KUAS, ARUH42KUAS, ARUH48KUAS, ARU36RGLX, ARU42RGLX, ARU48RGLXUTD-LFNAAG-AC-00501
UTD-LFNB – 18,000 to 30,000 BTU18,000, 24,000 and 30,000 BTUARUH18KUAS, ARUH24KUAS, ARUH30KUAS, ARU18RGLX, ARU24RGLX, ARU30RGLXUTD-LFNBAG-AC-00502
UTD-LFNC – 12,000 BTU12,000 BTUARUH12KUAS, ARU12RGLXUTD-LFNCAG-AC-00503

Pick the size by the indoor unit’s capacity, shown in its model number (ARUH24KUAS = 24,000 BTU).

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandFujitsu
TypeLong-life filter for medium static ducted unit
UTD-LFNC12,000 BTU units
UTD-LFNB18,000, 24,000 and 30,000 BTU units
UTD-LFNA36,000, 42,000 and 48,000 BTU units
Unit capacity18,000, 24,000 and 30,000 BTU
Units listed by FujitsuARUH18KUAS, ARUH24KUAS, ARUH30KUAS, ARU18RGLX, ARU24RGLX, ARU30RGLX
Part no.UTD-LFNB
AirGreen codeAG-AC-00502
04 · Before installing

What to know before installing

  • Read the indoor unit model number: the size depends on its capacity.
  • Switch off the unit before reaching the filter.
  • A clogged filter cuts airflow: check it every season.
  • Follow the unit’s installation manual for the filter location.
05 · Goes with

You may also need

Same category
Original parts
See all
06 · Questions

Frequently asked questions

Which filter for my ducted unit?

Fujitsu lists UTD-LFNC for 12,000 BTU units, UTD-LFNB for 18, 24 and 30,000 BTU and UTD-LFNA for 36, 42 and 48,000 BTU. The number after ARUH or ARU in the model number is the capacity.

Does it fit a slim duct unit?

Fujitsu lists it for its medium static ducted units (ARUH and ARU…RGLX). For another type of unit, send us the model number.

How often should I check it?

At least every change of season, more often during renovations or with pets.

Can you install it?

Yes. We fit it when installing or servicing your ducted unit, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A genuine filter for your Fujitsu ducted unit

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.