DETTSON Suprême Modulante SUP15-M240V12 Electric Furnace | 15 kW - 240V

In stock

The 15 kW Dettson Suprême Modulante: an electric furnace whose output varies from 0 to 100 % with demand, with an ECM motor.

Model numberSUP15-M240V12

15 kWat 240 V (11.3 kW at 208 V)
0 to 100 %output modulation
2.5 tonsmax. cooling with Smart Duct
240/208 V · 2 wiresModulatingSmart Duct® compatible
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP15-M240V12
ManufacturerDettson
SeriesSuprême Modulante (ECM)
Output15 kW at 240 V
Power supply240/208 V, 1 ph, 60 Hz
MotorECM 1/2 HP
ThermostatModulating or communicating

Electric heat that adjusts continuously, from 0 to 100 %

The Suprême Modulante in a few words

Most electric furnaces work in steps: they heat, stop, then start again. The Dettson Suprême Modulante SUP15-M240V12 works differently. Its solid-state control varies the output of the elements from 0 to 100 %, based on the demand sent by the thermostat. It delivers up to 15 kW at 240 V (11.3 kW at 208 V) and moves air with a 1/2 HP ECM motor.

A control interface lets you set up the whole unit, and the furnace accepts two types of thermostats: modulating, which sends a demand from 5 to 100 %, or communicating, connected with an RJ11 cable.

Who it is for

It is for homeowners who want steady central electric heat and who think long term. It is compatible with Dettson’s Smart Duct® small ducts, a useful option when there is no room for conventional ductwork, for example during a renovation in a Montreal plex or a house on the North Shore. In that configuration, Dettson publishes a maximum airflow of 1,000 CFM and maximum cooling of 2.5 tons.

For conventional ducts, Dettson’s sheet and manual do not give the same maximum values. We therefore validate them before choosing the coil, rather than promising you an uncertain figure.

With a heat pump, through a Quebec winter

Dettson designed the Suprême Modulante for its Right-Sized® system, in combination with its heat pumps. With a communicating system and a coil on the return, the elements and the heat pump can run at the same time. With a two-stage or modulating heat pump, backup is automatic, through the CALME and FUSION modes, via the K03081 interface. In very cold weather, the elements can therefore add to the heat pump’s output without shutting it off.

Installation by AirGreen

A family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. For a modulating furnace, our work includes:

  • the free on-site estimate and a detailed written quote;
  • checking the circuit: 80 A maximum breaker at 240 V and 78.6 A ampacity according to Dettson;
  • choosing and wiring the modulating or communicating thermostat;
  • connecting to the ducts, setting up the interface and commissioning.

The furnace is multi-position: upflow, downflow with the DFB-SUP base depending on the floor, horizontal or suspended. We install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

Your next step

Ask for a free estimate: we assess your ducts, your electrical service and your heat-pump project, then give you a written quote. Consider financing to spread out the investment.

01 · What it is for

Electric heat that follows the home’s demand

The SUP15-M240V12 modulates the output of its elements from 0 to 100 % with a solid-state control. Driven by a modulating or communicating thermostat, it matches its heat to the actual need instead of only running on and off.

  • Homes that want steadier central electric heat
  • Small-duct Smart Duct® systems
  • A Right-Sized® system with a Dettson heat pump
  • Replacing an old furnace in a home that already has ductwork
0 to 100 % modulationElement output varies continuously, driven by a 5 to 100 % signal from the thermostat.
Ready for a heat pumpWith a communicating system, the elements and the heat pump can run at the same time (coil on the return).
Control interfaceAn interface lets you set up the whole unit.
Compatible with
K03081DFB-SUP
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Modulante, ECM motor
TypeModulating electric furnace with elements, multi-position
Output15 kW at 240 V · 11.3 kW at 208 V
Heating output at 208 V38,442 BTU/h
Modulation0 to 100 % of output (solid state)
Control signalPWM demand from 5 to 100 % (modulating thermostat) or communicating protocol from 5 to 100 %
ThermostatModulating (V/W2, C, R, G + Y1, Y2, O, DH) or communicating (1, 2, R, C, RJ11 cable)
Power supply240/208 V, 1 ph, 60 Hz, 2 wires (3 wires possible with accessories)
Element current62.1 / 53.8 A (240 / 208 V)
Motor current2.3 / 2.7 A (240 / 208 V)
Total current64.4 / 56.5 A (240 / 208 V)
Ampacity78.6 / 69.2 A (240 / 208 V)
Max. breaker80 / 70 A (240 / 208 V)
MotorECM, 1/2 HP
Blower wheel12 x 8
Max. airflow (Smart Duct®)1,000 CFM
Max. cooling (Smart Duct®)2.5 tons
With a heat pumpSimultaneous operation with a communicating system (coil on the return); automatic backup with a two-stage or modulating heat pump (CALME / FUSION modes); K03081 interface
PositionsUpflow (factory), downflow (DFB-SUP base), horizontal left or right, suspended
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wiring
Model numberSUP15-M240V12
03 · Before installing

What to know before installing

  • Sold alone, an electric furnace is not a heat pump: it does not qualify for the LogisVert grant.
  • Dedicated circuit: 80 A maximum breaker at 240 V (70 A at 208 V) and 78.6 A ampacity at 240 V according to Dettson.
  • Modulation requires a modulating thermostat or a communicating thermostat (RJ11 cable).
  • For conventional ducts, Dettson’s sheet and manual do not give the same airflow or the same maximum cooling: we confirm these values before matching a coil.
  • The air-conditioning or heat-pump coil is not included.
  • In downflow, the DFB-SUP base may be required depending on the type of floor.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

What does “modulating” mean?

The output of the elements varies from 0 to 100 % through a solid-state control, instead of only going from off to full power. The thermostat sends a demand from 5 to 100 %.

Which thermostat is needed?

A modulating thermostat (V/W2, C, R, G, Y1, Y2, O, DH terminals) or a communicating thermostat connected with an RJ11 cable. We choose it with you based on the rest of the system.

Can it heat at the same time as a heat pump?

Yes, with a communicating system and a coil on the return. With a two-stage or modulating heat pump, backup is automatic (CALME and FUSION modes), through the K03081 interface.

My ducts are small. Is it compatible?

The Suprême Modulante is compatible with Smart Duct® small ducts. In that case, Dettson publishes a maximum airflow of 1,000 CFM and maximum cooling of 2.5 tons.

Does it qualify for a grant?

No. Sold alone, an electric furnace is not a heat pump and does not qualify for the LogisVert grant.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 15 kW Dettson modulating furnace, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.