The Dettson Suprême Modulante SUP18-M240V12: 18 kW of electric heat modulated from 0 to 100 %, designed to work with Dettson heat pumps.

Model numberSUP18-M240V12

18 kWat 240 V (13.5 kW at 208 V)
0 to 100 %modulated output
1,000 CFMmax. airflow with Smart Duct
240/208 V · 2 wiresRight-Sized® systemCommunicating thermostat
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP18-M240V12
ManufacturerDettson
SeriesSuprême Modulante (ECM)
Output18 kW at 240 V
Power supply240/208 V, 1 ph, 60 Hz
Ampacity94.7 A at 240 V
Heat-pump interfaceK03081

Electric heat that works with your heat pump, not beside it

A furnace designed for a complete system

With an ordinary electric furnace, the heat pump and the elements take turns: one heats, then the other. The Dettson Suprême Modulante SUP18-M240V12 was designed for Dettson’s Right-Sized® system, in combination with its heat pumps, including the Alizé for modulating cooling. With a communicating system and a coil on the return, the elements can heat at the same time as the heat pump.

With a two-stage or modulating heat pump, backup is automatic through two modes that Dettson calls CALME and FUSION, via the K03081 interface. Everything is driven by a demand from 5 to 100 %, sent by a modulating or communicating thermostat.

Dettson’s figures

The furnace delivers up to 18 kW at 240 V, or 13.5 kW and 46,130 BTU/h at 208 V. Its solid-state control modulates the element output from 0 to 100 %. The 1/2 HP ECM motor moves the air; with Smart Duct® small ducts, Dettson publishes a maximum airflow of 1,000 CFM and maximum cooling of 2.5 tons. For conventional ducts, the sheet and the manual do not agree: we confirm the values with you before choosing the coil.

Which home it suits

This model is for homeowners who are investing in a central heat pump and want gradual backup heat for cold days. Whether you are in Montreal, Laval or on the South Shore, we start with the heating load calculation: that is what confirms whether 18 kW is the right size.

The furnace is also compatible with Dettson’s Smart Duct® small ducts, an option worth considering when the existing ductwork has to be redone or there is no room for conventional ducts.

On the electrical side, Dettson publishes a 94.7 A ampacity and a 100 A maximum breaker at 240 V. The furnace is multi-position and approved for zero clearance; it is 36 1/2 in high and 22 in deep.

Our installation

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work, so we can install the furnace, the heat pump and their control wiring. Our work includes:

  • the free on-site estimate and a written quote;
  • installing the furnace and the electrical circuit;
  • placing the coil on the return, a condition for simultaneous operation;
  • connecting the modulating or communicating thermostat;
  • setting up the interface with the heat pump, then commissioning.

We also serve Longueuil and the North Shore.

Start with an estimate

Tell us about your heat-pump and furnace project: the estimate is free and the quote is in writing. Financing options are available.

01 · What it is for

The electric furnace of a Right-Sized® system

Dettson designed the Suprême Modulante for its Right-Sized® system, in combination with its heat pumps. With a communicating system, the SUP18-M240V12 can heat at the same time as the heat pump and modulate its output from 0 to 100 %.

  • Right-Sized® systems with a Dettson heat pump, including the Alizé for modulating cooling
  • Ducted homes that want gradual backup heat with a two-stage or modulating heat pump
  • Small-duct Smart Duct® systems
  • Replacing an 18 kW electric furnace in a home that already has ductwork
Simultaneous heatingWith a communicating system and a coil on the return, the elements and the heat pump can run together.
CALME and FUSION modesAutomatic backup with a two-stage or modulating heat pump, through the K03081 interface.
Fine controlPWM demand from 5 to 100 % with a modulating thermostat, or communicating protocol from 5 to 100 %.
Compatible with
K03081DFB-SUP
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Modulante, ECM motor
TypeModulating electric furnace with elements, multi-position
Output18 kW at 240 V · 13.5 kW at 208 V
Heating output at 208 V46,130 BTU/h
Modulation0 to 100 % of output (solid state)
Control signalPWM demand from 5 to 100 % (modulating thermostat) or communicating protocol from 5 to 100 %
ThermostatModulating (V/W2, C, R, G + Y1, Y2, O, DH) or communicating (1, 2, R, C, RJ11 cable)
With a heat pumpSimultaneous operation with a communicating system (coil on the return); automatic backup with a two-stage or modulating heat pump (CALME / FUSION modes); K03081 interface
Power supply240/208 V, 1 ph, 60 Hz, 2 wires (3 wires possible with accessories)
Element current75.8 / 65.7 A (240 / 208 V)
Motor current2.3 / 2.7 A (240 / 208 V)
Total current78.1 / 68.4 A (240 / 208 V)
Ampacity94.7 / 83.2 A (240 / 208 V)
Max. breaker100 / 90 A (240 / 208 V)
MotorECM, 1/2 HP
Blower wheel12 x 8
Max. airflow (Smart Duct®)1,000 CFM
Max. cooling (Smart Duct®)2.5 tons
PositionsUpflow (factory), downflow (DFB-SUP base), horizontal left or right, suspended
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wiring
Model numberSUP18-M240V12
03 · Before installing

What to know before installing

  • Sold alone, an electric furnace is not a heat pump: it does not qualify for the LogisVert grant.
  • Simultaneous operation with the heat pump requires a communicating system and a coil on the return.
  • Dedicated circuit: 100 A maximum breaker at 240 V (90 A at 208 V) and 94.7 A ampacity at 240 V.
  • For conventional ducts, Dettson’s sheet and manual do not give the same airflow or the same maximum cooling: we confirm these values before matching a coil.
  • The coil and the heat pump are not included.
  • In downflow, the DFB-SUP base may be required depending on the type of floor.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

What is the Right-Sized® system?

It is the name Dettson gives to the combination of the Suprême Modulante with its heat pumps, including the Alizé for modulating cooling.

Can the elements and the heat pump heat at the same time?

Yes, with a communicating system and a coil on the return. With a two-stage or modulating heat pump, backup is automatic through the CALME and FUSION modes, via the K03081 interface.

Is a special thermostat needed?

Yes: a modulating thermostat (V/W2, C, R, G, Y1, Y2, O, DH) or a communicating thermostat connected with an RJ11 cable. It sends the 5 to 100 % demand.

What electrical circuit should I plan for?

A 100 A maximum breaker at 240 V (90 A at 208 V). Dettson publishes a 94.7 A ampacity and a 78.1 A total current at 240 V.

Does it qualify for a grant?

No. Sold alone, an electric furnace is not a heat pump and does not qualify for the LogisVert grant.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your 18 kW Suprême Modulante, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.