DETTSON Suprême Modulante SUP27-M240V20 Electric Furnace | 27 kW - 240V

In stock

The 27 kW Dettson Suprême Modulante: a modulating electric furnace that can run at the same time as a heat pump, in a communicating system.

Model numberSUP27-M240V20

27 kWat 240 V (20.3 kW at 208 V)
0 to 100%solid-state modulation
5 to 100%demand sent by the thermostat
240/208 V · single phaseRight-Sized® system2 supply circuits
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP27-M240V20
ManufacturerDettson
SeriesSuprême Modulante
Output27 kW at 240 V · 20.3 kW at 208 V
With a heat pumpSimultaneous operation in communicating mode
Heat pump interfaceK03081
Max. breakers60 A + 90 A at 240 V

The modulating furnace that works with your heat pump, not instead of it

An electric furnace designed around the heat pump

Many homeowners who add a central heat pump keep an electric furnace for the coldest days. The Dettson Suprême Modulante SUP27-M240V20 goes further than simple backup: in a communicating system, with the coil on the return side, its elements can run at the same time as the heat pump. Dettson also provides automatic backup with a 2-stage or modulating heat pump, using the CALME and FUSION modes, as well as the K03081 interface.

The furnace delivers 27 kW at 240 V, or 20.3 kW at 208 V. Its output is modulated by solid-state controls, from 0 to 100%, based on a 5 to 100% demand sent by a modulating thermostat (PWM signal) or by a communicating thermostat. Dettson builds it into its Right-Sized® system with its heat pumps, and names the Alizé for modulating cooling. It is therefore best suited to a complete central heating and cooling project, designed as a whole.

How it is installed in a home in the region

Take a semi-detached house on the North Shore that is switching to a central heat pump. The SUP27-M240V20 takes the place of the old furnace: it is 36 1/2 in high and 22 in deep, weighs 105 lb, is approved for zero clearance and installs in upflow, downflow, horizontal or suspended position. Dettson states that it works with Smart Duct® small ducts as well as conventional ductwork.

The electrical panel has to take two circuits: a breaker of no more than 60 A for terminal block 1 and one of 90 A for block 2, at 240 V (50 A and 80 A at 208 V). The published total current is 118.8 A at 240 V, and both copper and aluminum wire are approved. One point calls for care: the maximum cooling capacity is not the same in every Dettson document. We therefore confirm it before choosing the coil and the heat pump.

AirGreen’s role in your project

AirGreen is a family business established in Montreal for more than fifteen years. With our RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work, we carry out the whole system, from the heat pump to the furnace:

  • free in-home estimate and assessment of heating and cooling needs;
  • choice of the heat pump, the coil and the communicating or modulating thermostat;
  • installation of the furnace and of the coil on the return side, and connection to the ductwork;
  • connection of the two circuits using the breaker sizes Dettson publishes;
  • commissioning, setup of the control interface and of the backup modes.

We serve Montreal, Laval, Longueuil, the South Shore and the North Shore.

Let’s plan your system

Ask for your free in-home estimate for a 27 kW Suprême Modulante paired with a heat pump. You receive a written quote, and financing is available.

01 · What it is for

The electric partner of a central heat pump

The SUP27-M240V20 modulates its output from 0 to 100% and can work with a heat pump: in a communicating system, with the coil on the return side, the elements and the heat pump run at the same time. Dettson builds it into its Right-Sized® system with its heat pumps.

  • Adding a Dettson central heat pump with modulated electric backup heat
  • Communicating systems where the heat pump and the elements run together
  • Automatic backup with a 2-stage or modulating heat pump (CALME and FUSION modes)
  • Homes with conventional ductwork or with Smart Duct® small ducts
Simultaneous operationWith a communicating system and the coil on the return side, the elements supplement the heat pump while it runs.
CALME and FUSION modesThe automatic backup modes Dettson publishes for use with a 2-stage or modulating heat pump.
0 to 100% modulationSolid-state modulation, controlled from 5 to 100% by a PWM signal or by communicating protocol.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Modulante (ECM motor)
TypeElectric furnace with elements, modulating, multi-position
Output at 240 V27 kW
Output at 208 V20.3 kW
Heating output at 208 V69,195 BTU/h
ModulationSolid-state, 0 to 100% of output
Control signalPWM demand from 5 to 100% (modulating thermostat) or communicating protocol from 5 to 100%; triac board
ThermostatModulating (V/W2, C, R, G + Y1, Y2, O, DH) or communicating (1, 2, R, C, RJ11 cable)
Heat pumpSimultaneous operation with a communicating system (coil on return); automatic backup with a 2-stage or modulating heat pump (CALME / FUSION modes); K03081 interface
DuctworkCompatible with Smart Duct® small ducts
Power supply240/208 V, 1 ph, 60 Hz, 2-wire (3-wire possible for 120–208/240 V, accessories)
Total current118.8 A (240 V) · 104.5 A (208 V)
Element current113.6 A (240 V) · 98.5 A (208 V)
Motor current5.2 A (240 V) · 6.0 A (208 V)
Ampacity (CSA C22.2-236)Block 1: 53.1 / 48.0 A · block 2: 90.0 / 78.0 A (240 / 208 V)
Maximum breakerBlock 1: 60 / 50 A · block 2: 90 / 80 A (240 / 208 V)
MotorECM, 1 HP
Blower wheel12 x 9
ConfigurationMulti-position: upflow (factory), downflow (DFB-SUP base on a combustible floor), horizontal left or right; suspended installation allowed
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wire
Model numberSUP27-M240V20
03 · Before installing

What to know before installing

  • Two supply circuits: terminal block 1, breaker of no more than 60 A at 240 V (50 A at 208 V); terminal block 2, breaker of no more than 90 A at 240 V (80 A at 208 V).
  • Ampacity calculated per CSA C22.2-236: 53.1 A and 90.0 A at 240 V; 48.0 A and 78.0 A at 208 V.
  • Simultaneous operation with the heat pump requires a communicating system and a coil on the return side; Dettson provides the K03081 interface.
  • Controlled by a modulating thermostat (terminals V/W2, C, R, G, Y1, Y2, O, DH) or a communicating one (terminals 1, 2, R, C and RJ11 cable).
  • The maximum cooling capacity differs from one Dettson document to another: we confirm it before choosing the coil.
  • For downflow on a combustible floor, the furnace sits on the DFB-SUP base.
  • The furnace alone is not a heat pump: it does not qualify for the LogisVert grant.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

Can the heat pump and the elements run at the same time?

Yes, under two conditions Dettson publishes: a communicating system and a coil on the return side. Dettson also provides the K03081 interface for the heat pump.

What are the CALME and FUSION modes?

They are the automatic backup modes Dettson provides when the furnace is paired with a 2-stage or modulating heat pump. We set them according to the chosen heat pump at commissioning.

Which heat pump should it be paired with?

Dettson pairs it with its own heat pumps in its Right-Sized® system and names the Alizé for modulating cooling. Since the maximum cooling capacity varies from one Dettson document to another, we confirm it before choosing the coil.

Does it need two electrical circuits?

Yes. Block 1 needs a breaker of no more than 60 A at 240 V and block 2, no more than 90 A at 240 V. We check the electrical service and the panel during the free estimate.

Does the furnace qualify for the LogisVert grant?

Not on its own. An electric furnace is not a heat pump and does not qualify for Hydro-Québec’s LogisVert grant.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 27 kW Suprême Modulante, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.