DETTSON Suprême Modulante SUP23-M240V12 Electric Furnace | 23 kW - 240V

In stock

The 23 kW Dettson Suprême Modulante electric furnace, with a 1/2 HP ECM motor, compatible with Smart Duct® small ducts.

Model numberSUP23-M240V12

23 kWat 240 V (17.3 kW at 208 V)
1,000 CFMwith Smart Duct® small ducts
2.5 tonsmax. cooling with Smart Duct®
240/208 V · single phase0 to 100% modulationSmart Duct® compatible
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP23-M240V12
ManufacturerDettson
SeriesSuprême Modulante
Output23 kW (240 V) · 17.3 kW (208 V)
MotorECM, 1/2 HP
Smart Duct®1,000 CFM · 2.5 tons
Max. breaker125 A (240 V and 208 V)

Modulating heat that works with small ducts

A 23 kW furnace that meters its heat

The Dettson Suprême Modulante SUP23-M240V12 is an electric furnace with elements rated 23 kW at 240 V (17.3 kW at 208 V). Its solid-state control modulates output from 0 to 100%, and the thermostat, modulating or communicating, sends it a demand that ranges from 5 to 100%. The house therefore receives the amount of heat it calls for, without the back-and-forth of a furnace that runs all-or-nothing. The blower is driven by a 1/2 HP ECM motor, and a control interface lets the whole unit be adjusted.

Designed for Smart Duct® small ducts

What sets this model apart is its compatibility with Dettson’s Smart Duct® small ducts. With this type of system, the manufacturer publishes a maximum airflow of 1,000 CFM and cooling of up to 2.5 tons. It is an interesting route for an existing house where it would be hard to run large ducts through finished walls and floors, for example a townhouse or a renovated two-storey home.

The furnace also installs on conventional ducts; in that case, we confirm the allowable cooling capacity in Dettson’s documentation before choosing the coil. It is multi-position (upflow, downflow, horizontal), can be suspended and is approved for zero clearance, mobile homes and copper or aluminum wire.

With a Dettson heat pump

Dettson presents the Suprême Modulante as the base of its Right-Sized® system, paired with its central heat pumps. In a communicating system, with the coil on the return side, the heat pump and the elements can heat at the same time. With a 2-stage or modulating heat pump, the furnace takes over automatically using the CALME and FUSION modes; the K03081 interface links the two units.

How AirGreen carries out the project

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. For a small-duct project, planning matters as much as the equipment:

  1. free on-site estimate, with a heating calculation and mapping of the duct routes;
  2. panel check: total current of 98.8 A at 240 V, 125 A maximum breaker;
  3. written quote specifying the duct system, the thermostat and, where applicable, the heat pump;
  4. installation, electrical and air-side connections, thermostat programming;
  5. commissioning and a walk-through of the control interface.

An electric furnace sold alone is not a heat pump and does not qualify for the LogisVert grant.

Take the next step

For a home in Montreal, Laval, Longueuil, the North Shore or the South Shore, ask for your free estimate and written quote. Financing options are available.

01 · What it is for

Modulating heat for a small-duct system

The SUP23-M240V12 modulates its element output from 0 to 100% and moves air with a 1/2 HP ECM motor. Dettson declares it compatible with Smart Duct® small ducts, for which it publishes 1,000 CFM and cooling of up to 2.5 tons.

  • Homes moving to a Smart Duct® small-duct system
  • Renovations where large ducts are hard to run
  • Right-Sized® systems with a Dettson central heat pump
  • Replacing an electric furnace with a modulating model
Smart Duct®: 1,000 CFMAirflow Dettson publishes with Smart Duct® small ducts, for cooling of up to 2.5 tons.
0 to 100% modulationSolid-state control; the modulating or communicating thermostat sends a 5 to 100% demand.
Heats alongside the heat pumpIn a communicating system, coil on the return, the heat pump and the elements can run together (CALME and FUSION modes).
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Modulante
TypeElectric furnace with elements, modulating, multi-position
Output at 240 V23 kW
Output at 208 V17.3 kW (58,944 BTU/h)
First-stage output13 kW (240 V) · 9.8 kW (208 V)
Modulation0 to 100% of output, solid-state (triac board)
Demand signal5 to 100% (PWM modulating thermostat or communicating protocol)
Power supply240/208 V, single phase, 60 Hz, 2-wire (3-wire possible for 120–208/240 V, with accessories)
Total current98.8 A (240 V) · 86.3 A (208 V)
Element current96.5 A (240 V) · 83.6 A (208 V)
Motor current2.3 A (240 V) · 2.7 A (208 V)
Ampacity119.3 A (240 V) · 104.5 A (208 V)
Maximum breaker125 A (240 V) · 125 A (208 V)
MotorECM, 1/2 HP
Blower wheel12 x 8
Maximum airflow (Smart Duct®)1,000 CFM
Maximum cooling (Smart Duct®)2.5 tons
ThermostatModulating (V/W2, C, R, G + Y1, Y2, O, DH) or communicating (1, 2, R, C, RJ11 cable)
Heat pumpSimultaneous operation in a communicating system (coil on return); automatic backup with a 2-stage or modulating heat pump (CALME / FUSION modes); interface K03081
ConfigurationUpflow (factory setting), downflow (DFB-SUP base on a combustible floor), horizontal left or right; suspended installation allowed
Approved forZero clearance, mobile homes, copper or aluminum wire
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Model numberSUP23-M240V12
03 · Before installing

What to know before installing

  • Sold alone, an electric furnace is not a heat pump: it does not qualify for the LogisVert grant.
  • The 1,000 CFM and 2.5-ton values apply to Smart Duct® small ducts; with conventional ducts, the capacity is confirmed in Dettson’s documentation before choosing the coil.
  • Dedicated circuit: total current of 98.8 A at 240 V (86.3 A at 208 V), ampacity of 119.3 A (104.5 A at 208 V), 125 A maximum breaker.
  • A modulating thermostat (V/W2, C, R, G, Y1, Y2, O, DH terminals) or a communicating one (1, 2, R, C terminals, RJ11 cable) is required for modulation.
  • Simultaneous operation with a heat pump: communicating system and coil on the return; interface K03081.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

What does Smart Duct® compatibility change?

Dettson declares the furnace compatible with its Smart Duct® small ducts. In that setup, it publishes a maximum airflow of 1,000 CFM and cooling of up to 2.5 tons. It is an option to consider when large ducts are hard to run.

And with conventional ducts?

The furnace also installs on a conventional duct system. The allowable cooling capacity in that case is confirmed in Dettson’s documentation; we validate it before choosing the coil.

How does it work with a heat pump?

In a communicating system, with the coil on the return, the heat pump and the elements can heat at the same time. With a 2-stage or modulating heat pump, the furnace takes over automatically (CALME and FUSION modes). Dettson presents this furnace as the base of its Right-Sized® system.

Which thermostat is needed?

A modulating thermostat (V/W2, C, R, G with Y1, Y2, O and DH) or a communicating one (1, 2, R, C, RJ11 cable). The demand sent to the furnace ranges from 5 to 100%.

Does it qualify for a grant?

Not on its own. An electric furnace is not a heat pump; it does not qualify for LogisVert.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 23 kW Suprême Modulante for small ducts, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.