DETTSON Suprême Modulante SUP25-M240V20 Electric Furnace | 25 kW - 240V

In stock

The 25 kW Dettson Suprême Modulante: an electric furnace whose output is modulated by solid-state controls from 5 to 100%, driven by a modulating or communicating thermostat.

Model numberSUP25-M240V20

5 to 100%output modulation
25 kWat 240 V (18.8 kW at 208 V)
1 HP ECMblower motor
240/208 V · single phaseSmart Duct® compatibleFurnace alone: no LogisVert grant
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP25-M240V20
ManufacturerDettson
SeriesSuprême Modulante
Output25 kW at 240 V · 18.8 kW at 208 V
Modulation5 to 100%, solid-state
ThermostatModulating or communicating
Maximum breaker150 A (240 V) · 125 A (208 V)

Electric heat modulated from 5 to 100%, in step with the house

The Suprême Modulante in a few words

The Dettson Suprême Modulante SUP25-M240V20 is a 25 kW electric furnace with elements at 240 V (18.8 kW at 208 V). What sets it apart is its control: the output of the elements is modulated by solid-state controls, from 5 to 100%. The furnace receives a 5 to 100% demand from a modulating thermostat, through a PWM signal, or from a communicating thermostat. A control interface is used to set up the whole unit, and a 1 HP ECM motor moves the air.

It suits homeowners who want central electric heating whose output adjusts to demand, and those who plan to add a Dettson heat pump in a Right-Sized® system. Dettson states that it works with conventional ductwork as well as with Smart Duct® small ducts.

In a home in the region

Whether the house is in Laval, on the South Shore or in a central Montreal neighbourhood, the furnace location often sets the rules. The SUP25-M240V20 is multi-position: upflow as configured at the factory, downflow, horizontal to the left or right, or suspended. It is 36 1/2 in high by 22 in deep, weighs 105 lb and is approved for zero clearance as well as for mobile homes. Its 20 x 20 in supply opening connects to the plenum, and it takes a 20 x 20 in filter.

The power supply is 240/208 V single-phase, 2-wire, on a single breaker of no more than 150 A at 240 V or 125 A at 208 V; copper and aluminum wire are both approved. The published total current reaches 108.7 A at 240 V, so we check the capacity of the electrical service before recommending this size.

If a heat pump is part of the project, Dettson allows the elements and the heat pump to run at the same time when the system is communicating and the coil is on the return side. The manufacturer also provides automatic backup with a 2-stage or modulating heat pump, using the CALME and FUSION modes.

How we install a modulating furnace

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work, so we handle the unit, the ductwork and the electrical connection. In practice:

  1. Free in-home estimate: we assess the heating needs, the electrical service, the location and the type of ductwork in place.
  2. Thermostat choice, modulating or communicating, based on the intended system and any heat pump.
  3. Installation of the furnace in the chosen position, then connection of the plenum and ductwork.
  4. Electrical connection using the breaker sizes Dettson publishes, commissioning and setup at the control interface.

We work throughout Greater Montreal: in Laval, in Longueuil, on the North Shore as well as the South Shore.

Get your quote

Ask for your free in-home estimate for the 25 kW Suprême Modulante. You receive a written quote, and financing is available.

01 · What it is for

Central electric heating that follows demand

The SUP25-M240V20 modulates the output of its elements with solid-state controls, from 5 to 100%, according to the demand sent by the thermostat. Its 1 HP ECM motor then moves the air through the ductwork.

  • Homes with ductwork where electric heat modulated to demand is wanted
  • Smart Duct® small-duct systems
  • Projects with a Dettson heat pump, in a Right-Sized® system
  • Replacing an old furnace, in upflow, downflow, horizontal or suspended position
5 to 100% modulationSolid-state modulation, controlled from 5 to 100% by a modulating thermostat (PWM signal) or by a communicating thermostat.
Smart Duct® small ductsDettson states that the Suprême Modulante is compatible with Smart Duct® small ducts.
Control interfaceAn interface for setting up the whole unit, according to Dettson.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Modulante (ECM motor)
TypeElectric furnace with elements, modulating, multi-position
Output at 240 V25 kW
Output at 208 V18.8 kW
Heating output at 208 V64,070 BTU/h
ModulationSolid-state, 5 to 100% of output
Control signalPWM demand from 5 to 100% (modulating thermostat) or communicating protocol from 5 to 100%; triac board
ThermostatModulating (V/W2, C, R, G + Y1, Y2, O, DH) or communicating (1, 2, R, C, RJ11 cable)
Heat pumpSimultaneous operation with a communicating system (coil on return); automatic backup with a 2-stage or modulating heat pump (CALME / FUSION modes); K03081 interface
DuctworkCompatible with Smart Duct® small ducts
Power supply240/208 V, 1 ph, 60 Hz, 2-wire (3-wire possible for 120–208/240 V, to connect accessories directly)
Total current108.7 A (240 V) · 95.7 A (208 V)
Element current103.5 A (240 V) · 89.7 A (208 V)
Motor current5.2 A (240 V) · 6.0 A (208 V)
Ampacity (CSA C22.2-236)131.1 A (240 V) · 115.6 A (208 V)
Maximum breaker150 A (240 V) · 125 A (208 V)
MotorECM, 1 HP
Blower wheel12 x 9
ConfigurationMulti-position: upflow (factory), downflow (DFB-SUP base on a combustible floor), horizontal left or right; suspended installation allowed
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wire
Model numberSUP25-M240V20
03 · Before installing

What to know before installing

  • 240/208 V single-phase, 60 Hz, 2-wire power supply (3-wire connection possible for 120–208/240 V, to connect accessories directly).
  • A single breaker of no more than 150 A at 240 V (125 A at 208 V); ampacity of 131.1 A at 240 V and 115.6 A at 208 V, calculated per CSA C22.2-236.
  • Dettson describes two control modes: modulating thermostat (terminals V/W2, C, R, G, Y1, Y2, O, DH) or communicating thermostat (terminals 1, 2, R, C and RJ11 cable).
  • With a heat pump, running the elements and the heat pump at the same time requires a communicating system, with the coil on the return side.
  • The maximum cooling capacity differs from one Dettson document to another: we confirm it before choosing the coil.
  • For downflow on a combustible floor, the furnace sits on the DFB-SUP base.
  • The furnace alone is not a heat pump: it does not qualify for the LogisVert grant.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

How does a modulating furnace differ from a staged furnace?

A staged furnace switches its elements on in steps. The SUP25-M240V20 instead modulates its output with solid-state controls from 5 to 100%, following the demand sent by a modulating or communicating thermostat.

Can I keep my current thermostat?

Dettson describes two control modes for this furnace: a modulating thermostat (terminals V/W2, C, R, G, Y1, Y2, O and DH) or a communicating thermostat (terminals 1, 2, R and C, RJ11 cable). We check whether your thermostat matches one of them during the estimate.

Does it work with a heat pump?

Yes. With a communicating system and the coil on the return side, the heat pump and the elements can run at the same time. Dettson also provides automatic backup with a 2-stage or modulating heat pump (CALME and FUSION modes) and the K03081 interface.

How much space does it need?

The furnace is 36 1/2 in high and 22 in deep, and weighs 105 lb. It is approved for zero clearance and installs in upflow, downflow, horizontal or suspended position. We measure the location during the estimate.

Does this furnace qualify for a grant?

No. Sold on its own, this modulating furnace does not qualify for Hydro-Québec’s LogisVert grant, since it is not a heat pump.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 25 kW Suprême Modulante, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.