ADP

ADP HE30924A140A0000AP Evaporator A-Coil | 1.5-2 Tons

In stock

The ADP HE30924A140A0000AP uncased evaporator A-coil: 24,000 BTU, a TXV and an 11 in coil height.

Model numberHE30924A140A0000AP

11 incoil height
800 CFMreference airflow at 24 MBTUH
TXVnon-bleed valve, R-410A
R-410AAir conditioning and heat pumpUncasedSold alone: no grant
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHE30924A140A0000AP
ManufacturerADP
Size1.5-2 tons · 24,000 BTU
TypeUncased A-coil
MeteringNon-bleed TXV (R-410A)
Suction connection3/4 in ODF
Weight22 lb

A low-profile coil that adds air conditioning to your central system

An A-coil for 1.5 to 2-ton systems

ADP’s HE30924A140A0000AP is an evaporator A-coil shipped without a cabinet. It sits in the plenum of your electric furnace or air handler and becomes the indoor part of a central air conditioner or central heat pump. Its capacity code 24 corresponds to 24,000 BTU, and ADP’s selection table lists its E30 slab in the 18 and 24 MBTUH rows: it is meant for homes with a 1.5 to 2-ton outdoor unit.

Its 11 in coil height is its main advantage. In a basement with a low ceiling, or above a unit that is already tall, every inch counts, and a taller coil would often mean rebuilding part of the ductwork. It suits bungalows, condos with a central system and small townhouses.

What the manufacturer built in

  • a non-bleed thermostatic expansion valve (TXV), designed for air conditioning and heat pumps on R-410A;
  • a copper coil with brazed connections, including a 3/4 in ODF suction connection;
  • a drain pan moulded from UV-resistant, 450°F polymer, treated with Microban antimicrobial additive;
  • factory testing: helium leak test and 500 psi air pressure test.

ADP publishes a reference airflow of 800 CFM at 24 MBTUH. Like any coil sold alone, it has no efficiency rating of its own: system performance depends on the outdoor unit and indoor unit it works with. For the same reason, it is not eligible for the LogisVert grant when sold alone.

In a Quebec home

The most common case among our customers: a house heated by an electric furnace that wants to add air conditioning, or install a central heat pump on the existing ductwork. The coil goes above the unit, in the plenum. Because its pan is 14.0 in wide and 19.5 in deep, we first check the plenum and unit dimensions so that everything fits cleanly.

The model is designed for upflow or downflow installation. If your unit lies horizontally, for example in a crawl space, we will recommend a cased multi-position HE coil instead.

What AirGreen’s installation covers

AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Our technicians:

  • assess your system on site, free of charge, and confirm the match with the outdoor unit;
  • adapt the plenum and set the coil;
  • braze the copper connections and connect the drain pan;
  • commission the system and check that it runs properly before leaving.

You receive a written quote before work begins. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.

Let’s talk about your project

Book your free in-home estimate: we confirm the match, measure the plenum and give you a written quote. Financing is available on our installation projects.

01 · What it is for

A low-profile coil for smaller central systems

The HE30924A140A0000AP sits in the plenum of an electric furnace or air handler and cools the air moving through the ductwork. ADP states it is compatible with air conditioning and heat pumps.

  • Adding central air conditioning to an existing electric furnace, with a 1.5 to 2-ton outdoor unit
  • Replacing an A-coil in a plenum where height is limited
  • Pairing a central heat pump with an air handler already in place
  • Bungalows, condos and small houses with ductwork
11 in tallThe E30 slab is 11 in high, an advantage in a shallow plenum or under a low basement ceiling.
Non-bleed TXVA thermostatic expansion valve ADP designs for both air conditioning and heat pump use, on R-410A.
UV-resistant panDrain pan moulded from UV-resistant, 450°F polymer with Microban antimicrobial additive.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerADP
SeriesHE
TypeUncased evaporator A-coil
Nominal size2 tons (24,000 BTU/h), capacity code 24
ADP selection tableE30 slab in the 18 and 24 MBTUH rows
Reference airflow800 CFM at 24 MBTUH
RefrigerantR-410A
Metering deviceNon-bleed TXV, air conditioning and heat pump (code 9)
ApplicationAir conditioning and heat pump (per ADP)
ConfigurationUpflow or downflow, right-hand uncased (code 00)
CoilE30 copper slab
Coil height11 in
Pan width14.0 in
Pan depth19.5 in
Drain panUV-resistant, 450°F polymer, Microban additive
Suction connection3/4 in ODF, copper, for brazing
Factory testingHelium leak test, 500 psi air pressure test
Weight22 lb
Manufacturer warranty5 years on parts, extendable to 10 years under ADP’s conditions
Model numberHE30924A140A0000AP
03 · Before installing

What to know before installing

  • Sold alone: not eligible for the LogisVert grant. A coil has no efficiency rating of its own; performance depends on the outdoor unit and indoor unit it is matched with.
  • Uncased coil: it must sit in the plenum or in a compatible cabinet, which we plan for in the quote.
  • The drain pan is 14.0 in wide and 19.5 in deep: we measure the plenum before ordering.
  • Designed for upflow or downflow installation; for a horizontal unit, the HE series offers cased multi-position models.
  • The outdoor unit, refrigerant lines and electric furnace or air handler are not included.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ADP
See all
06 · Questions

Frequently asked questions

Does this coil work with a heat pump?

Yes. ADP states that HE coils are compatible with air conditioning and heat pumps, and this model has a non-bleed TXV designed for both uses on R-410A.

Which outdoor unit can it be matched with?

ADP’s selection table lists the E30 slab in the 18 and 24 MBTUH rows, which corresponds to 1.5 to 2-ton outdoor units. ADP does not name a specific model: we check the match against the outdoor unit’s documentation before ordering.

Can it be installed horizontally?

ADP designs it for upflow or downflow installation. For a unit lying horizontally, we recommend a cased multi-position HE coil instead.

Does the coil qualify for a grant?

Not when sold alone: it is not eligible for the LogisVert grant. If you are replacing the whole system, ask us for a quote on a complete central heat pump.

What is the manufacturer’s warranty?

ADP provides a 5-year limited parts warranty from installation (no more than 6 years from manufacture), extendable to 10 years under the conditions of its extended warranty. In Quebec, not registering does not reduce coverage. Labour and refrigerant are not covered by the manufacturer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A compact ADP coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.