ADP

ADP HE34936A155A0000AP Evaporator A-Coil

In stock

The ADP HE34936A155A0000AP uncased evaporator A-coil: a 19 in high E34 slab, non-bleed TXV and R-410A.

Model numberHE34936A155A0000AP

19 incoil height
Code 3636,000 BTU/h nominal per ADP nomenclature
1,200 CFMreference airflow at 36 MBTUH
R-410AAir conditioning and heat pumpUncased · right-handSold alone: no grant
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHE34936A155A0000AP
ManufacturerADP
Capacity code36 (ADP nomenclature)
Coil height19 in
MeteringNon-bleed TXV (R-410A)
Suction connection3/4 in ODF
Weight35 lb

A 19 in ADP coil for more demanding central systems

Who the HE34936A155A0000AP is for

This ADP evaporator A-coil, shipped uncased, uses the E34 copper slab. In the manufacturer’s selection table, this slab appears in the 36 and 42 MBTUH rows, and the model’s capacity code is 36, which is 36,000 BTU/h nominal per ADP nomenclature. It is therefore aimed at central systems in that capacity range, found in large single-family homes, two-storey cottages or enlarged semi-detached homes.

It sits in the plenum of an electric furnace or air handler and becomes the indoor part of a central air conditioner or central heat pump. ADP states that its HE coils are compatible with air conditioning and heat pumps, and this model has a non-bleed TXV designed for both modes on R-410A. Paired with a heat pump, the same coil heats the house in winter, while the electric furnace stays in place for backup.

Height, the first thing to check

With a 19 in coil height, the vertical space above the unit becomes the deciding factor. In a finished basement, a beam or a low main duct can limit that space. That is why we measure the plenum at the visit and state in the quote any duct changes needed. The drain pan is 15.5 in wide and 19.5 in deep, and the coil weighs 35 lb.

ADP publishes a reference airflow of 1,200 CFM at 36 MBTUH. We check that your unit’s blower can deliver it before confirming the match.

Construction and manufacturer warranty

  • Copper connections for brazing, including the 3/4 in ODF suction.
  • UV-resistant, 450°F polymer drain pan treated with Microban antimicrobial additive.
  • Helium leak test and 500 psi air pressure test at the factory.
  • ADP 5-year limited parts warranty, extendable to 10 years under the conditions of its extended warranty; labour is not covered by the manufacturer.

Like any coil sold alone, it has no efficiency rating of its own and is not eligible for the LogisVert grant.

A complete installation by AirGreen

Established in Montreal for more than fifteen years, AirGreen is a family business holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We assess your project on site free of charge, give you a written quote, then our technicians set the coil, braze the connections, connect the drain and commission the system. Before leaving, they check operation in cooling and, where applicable, in heat pump mode. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.

Have us measure your plenum: the estimate is free, the quote is in writing and financing is available.

01 · What it is for

A tall coil, listed in the 36 and 42 MBTUH rows of ADP’s table

ADP’s selection table lists this coil’s E34 slab in the 36 and 42 MBTUH rows. Set in the plenum of an electric furnace or air handler, it forms the indoor part of a central air conditioner or heat pump.

  • Homes whose outdoor unit falls in the 36 or 42 MBTUH rows of ADP’s table
  • Adding a central heat pump to an existing electric furnace
  • Replacing an uncased A-coil of the same height
  • Mechanical rooms with enough vertical space above the unit
19 in coilThe E34 copper slab is 19 in high, on a 15.5 x 19.5 in pan.
36 and 42 MBTUH rowsADP’s selection table lists the E34 slab in these two capacity rows.
Non-bleed TXVDesigned for heat pump and air conditioning use on R-410A, with a reference airflow of 1,200 CFM at 36 MBTUH.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerADP
SeriesHE
TypeUncased evaporator A-coil
Capacity code36 (36,000 BTU/h nominal per ADP nomenclature)
ADP selection tableE34 slab in the 36 and 42 MBTUH rows
Reference airflow1,200 CFM at 36 MBTUH
RefrigerantR-410A
Metering deviceNon-bleed TXV, air conditioning and heat pump (code 9)
ApplicationAir conditioning and heat pump (per ADP)
ConfigurationUpflow or downflow, right-hand uncased (code 00)
CoilE34 copper slab
Coil height19 in
Pan width15.5 in
Pan depth19.5 in
Drain panUV-resistant, 450°F polymer, Microban additive
Suction connection3/4 in ODF, copper, for brazing
Factory testingHelium leak test, 500 psi air pressure test
Weight35 lb
Manufacturer warranty5 years on parts, extendable to 10 years under ADP’s conditions
Model numberHE34936A155A0000AP
03 · Before installing

What to know before installing

  • Sold alone: not eligible for the LogisVert grant. A coil has no efficiency rating of its own; performance depends on the outdoor unit and indoor unit it is matched with.
  • Plan for height: the coil is 19 in high. We measure the space in the plenum before confirming the model.
  • Uncased: it sits in the plenum or in a compatible cabinet, which we plan for in the quote. The pan is 15.5 in wide and 19.5 in deep.
  • Right-hand configuration (code 00), for upflow or downflow installation.
  • The outdoor unit, refrigerant lines and indoor unit are not included.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
ADP
See all
06 · Questions

Frequently asked questions

How much height does the plenum need?

ADP lists a coil height of 19 in. During the visit, we measure the space between the unit and the ductwork and state in the quote any duct changes needed.

Which outdoor unit should it be matched with?

ADP’s selection table lists the E34 slab in the 36 and 42 MBTUH rows, and the model’s capacity code is 36. ADP does not name a specific model: we confirm the match against the documentation of the chosen outdoor unit.

Does it work in heat pump mode?

Yes. ADP states that HE coils are compatible with air conditioning and heat pumps, and this model has a non-bleed TXV designed for both modes on R-410A.

What does the ADP warranty include?

The coil’s parts are covered for 5 years from installation, no more than 6 years from manufacture, and coverage can reach 10 years under the conditions of ADP’s extended warranty. In Quebec, not registering does not reduce coverage. Labour and refrigerant are excluded.

Does this coil qualify for the LogisVert grant?

No, a coil sold alone is not eligible. If you are replacing the whole system, we can offer you a complete central heat pump.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 19 in ADP coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.