up to 111 L

of water added to the air per day (HS2529 at 240 V: 29.3 US gal/day)

  • Bypass12 to 17 gal/day · 24 V valve
  • Fan-powered18 gal/day · 120 V, 1 A
  • Steam11.1 to 29.3 gal/day · 120, 208 or 240 V
Find my humidifier

1 US gal = 3.785 L · 1 US pint = 0.473 L. Values from Clean Comfort spec sheets.

  • 3ways to humidify: bypass, fan, steam
  • 65 to 155pints/day removed by our dehumidifiers (80 °F, 60% RH)
  • 5 to 10 yearson parts depending on the model, in an owner-occupied home (section 06)
  • On sitefree in-home estimate, price on quotation
AirGreen × Clean ComfortSold and installed by AirGreenBypass, fan-powered or steamHS2529 steam: 29.3 US gal/day at 240 VDV155: 155 pints/day at 80 °FClean Comfort warranty: 5 years on parts for 2nd-generation HE units in an owner-occupied homeMontréal · Laval · Longueuil · South Shore · North Shore

01 Find the right humidifier

Two questions, one Clean Comfort model

Clean Comfort’s spec sheets set the models apart by control (manual or automatic) and by output in US gallons per day. Answer both questions: the result only shows models we offer.

1. Which control do you want?

2. How much output?

Our suggestion

Clean Comfort HE17M2HE17M2Bypass · manual control · 17 gal/day

Second generation: 7 W 24 V valve, 12.63 × 9.68 in. plenum opening, HE26E1004 pad.

The final choice is made on site: room around the furnace, water supply, drain and electrical circuit.

Your home’s volume

For three models, Clean Comfort publishes a maximum volume in cubic feet. Living area × ceiling height:

Volume: 14,400 cu ft

  • HE12A2 (not offered in our shop)16,000 cu ft
  • HE17A220,000 cu ft
  • HE18FA224,000 cu ft

All three models cover this volume according to Clean Comfort.

Clean Comfort publishes no volume for the HE12M2, HE17M2 or the steam models: for those, we assess on site.

02 Evaporative humidifiers

Bypass or fan-powered: each model’s sheet

An evaporative humidifier pushes warm air from the heating system through a wet pad. Bypass models use a duct linking the supply and return; the HE18FA2 adds its own fan on 120 V. The HE12M and HE17M are the previous generation.

Model Type Control US gal/day Published coverage Opening (in., H × W) Power Pad Sheet
HE12M2BypassManual12not published9.43 × 9.2824 V · 7 WHE22E1003SS-HE12M2_HE17M2 (11/20)
HE17M2BypassManual17not published12.63 × 9.6824 V · 7 WHE26E1004SS-HE12M2_HE17M2 (11/20)
HE17A2BypassAutomatic1720,000 cu ft12⅝ × 9¾24 V · 0.75 AHE26E1004SS-HE12A2_HE17A2 (11/20)
HE18FA2Fan-poweredAutomatic1824,000 cu ft13½ × 14 1/16 (as printed)120 V · 1 AHE26E1004SS-HE18FA2_HE18FM2 (11/20)
HE12MBypass · 1st gen.Manual121,200 sq ft (average home) · 2,000 sq ft (very tight)9½ × 8⅞24 VHEP-GA10SS-HE12-B (12/15)
HE17MBypass · 1st gen.Manual171,650 sq ft (average home) · 2,800 sq ft (very tight)12 × 8⅞24 VHEP-GA19SS-HE17-B (12/15)

Output measured by Clean Comfort with 120 °F (49 °C) plenum air on the 1st-generation sheets; the 2nd-generation sheets do not state the condition. The DV6062A1001 automatic control comes with the HE17A2 and HE18FA2 according to Clean Comfort’s website.

03 Steam humidifiers

The voltage at your panel sets the output

Clean Comfort’s HS units heat water in an internal electrode cylinder to make steam, which the system’s fan spreads through the house. The same unit does not produce the same amount at every voltage: pick yours.

HS1122-120/240V

22.1 US gal/day

2.9 kW · 12 A · fuse 15 A

HS2529-208/240V

29.3 US gal/day

3.8 kW · 15.9 A · fuse 20 A

Source: SS-HS-HUM sheet (rev. 5/18). The HS2529 does not run on 120 V.

Steam models from the 2015 brochure

ModelVoltageUS gal/dayCurrentBreaker
HS11-120120 V1112 A15 A
HS22-240240 V2212 A15 A
HS29-208208 V2918.1 A25 A

Source: Clean Comfort brochure PM-CCLINE 12-15. Clean Comfort’s current website presents the HS1122-120/240V and HS2529-208/240V.

AirGreen × Clean Comfort

Clean Comfort’s units, a local install.

Clean Comfort supplies the humidifiers and dehumidifiers; AirGreen picks with you the one that suits your home and installs it. Each does what it does best.

Clean Comfort

What Clean Comfort brings

  • Three ways to humidifyBypass on 24 V, fan-powered on 120 V or steam on 120, 208 or 240 V, according to Clean Comfort’s sheets.
  • Up to 29.3 US gal/dayThe HS2529 steam unit on 240 V; the evaporative units give 12 to 18 US gal/day.
  • Dehumidifiers from 65 to 155 pints/dayDucted whole-home units, MERV 11 filter, rated at 80 °F and 60% RH.
  • Written warranties5 years on parts for 2nd-generation HE units and 6 years for the DV065, DV090 and DV120 in an owner-occupied home, on the certificates’ terms.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenHumidifiers and dehumidifiers, in Montréal, Laval, Longueuil, the South Shore and the North Shore.
  • Free estimateWe look at the space around your furnace, the water, the drain and the electrical circuit, at your home.
  • Programs checkedLogisVert, Rénoclimat, Énergir, Hilo and federal programs, read on October 14, 2026: none subsidizes these units, and ENERGY STAR lists no Clean Comfort model.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.

The result: the right Clean Comfort unit for winter and for summer, chosen with you, at home.

04 Whole-home dehumidifiers

The cooler the air, the less they remove

Clean Comfort rates its dehumidifiers at 80 °F and 60% relative humidity. Several sheets also give the capacity at 70 °F and 60 °F: pick a temperature.

  • DV06565 pints/day (31 L)
  • DV07070 pints/day (33 L)
  • DV09090 pints/day (43 L)
  • DV09898 pints/day (46 L)
  • DV120120 pints/day (57 L)
  • DV155155 pints/day (73 L)

“Not published”: the model’s sheet gives no value at that temperature. 1 US pint = 0.473 L.

Model L/kWh (80 °F) Airflow Ducts Power MERV 11 filter (in.) Published range Control Published area Weight Sheet
DV0652.22160 cfm8 in.120 V · 5.2 A9 × 11 × 0.7534–135 °F (outside the cabinet)Built innot published60 lbSS-DV065 (10/20)
DV0702.4150 cfm8 in.110-120 V · 5.1 A · 580 W9 × 11 × 149–95 °FOptional1,800 sq ft55 lbSS-DV070 (2/14)
DV0902.9320 cfm10 in. + 6 in. port120 V · 5.3 A14 × 17.5 × 1.7534–135 °F (outside the cabinet)Externalnot published86 lbSS-DV090 (10/20)
DV0982.9320 cfm10 in. + 6 in. port115 V · 5.9 A · 670 W14 × 17.5 × 1.7549–95 °F (inlet air)Optional2,300 sq ft81 lbSS-DV098 (10/15)
DV1202.9400 cfm10 in. + 6 in. port120 V · 7.3 A14 × 17.5 × 1.7534–135 °F (outside the cabinet)Externalnot published95 lbSS-DV120 (10/20)
DV1553.5391 cfm10 in. (oval outlet) + 6 in. port110-120 V · 8 A · 920 W16 × 20 × 256–95 °FOptional3,500 sq ft140 lbSS-DV155 (2/14)

Airflow with no static pressure (0 in.). Clean Comfort’s current website presents the DV065, DV090 and DV120; the DV070, DV098 and DV155 come from 2014 and 2015 sheets.

05 Upkeep

What wears out, and its part number

Evaporative pads

  • HE12M2HE22E1003 or CCF-A10
  • HE17M2 · HE17A2 · HE18FA2HE26E1004 or CCF-A35
  • HE12MHEP-GA10
  • HE17MHEP-GA19

For the 1st generation, Clean Comfort calls for a new pad once or twice a season. The 2nd-generation sheets give no interval.

Steam cylinder

  • HS1122 · HS2529HSP-2573990

Automatic fill and drain; the sheet does not publish the cylinder’s life. The steam warranty does not cover the cylinder.

Dehumidifier filters

  • DV065MERV 11 · 9 × 11 × 0.75 in.
  • DV070MERV 11 · 9 × 11 × 1 in.
  • DV090MERV 11 · 14 × 17.5 × 1.75 in.
  • DV098MERV 11 · 14 × 17.5 × 1.75 in.
  • DV120MERV 11 · 14 × 17.5 × 1.75 in.
  • DV155MERV 11 · 16 × 20 × 2 in.
AirGreen × Clean ComfortSold and installed by AirGreenBypass, fan-powered or steamHS2529 steam: 29.3 US gal/day at 240 VDV155: 155 pints/day at 80 °FClean Comfort warranty: 5 years on parts for 2nd-generation HE units in an owner-occupied homeMontréal · Laval · Longueuil · South Shore · North Shore

06 Manufacturer warranty

What Clean Comfort covers, and on what terms

Clean Comfort’s certificates cover parts. The two 2022 certificates (PWOHEHUB and PWODVDHB) exclude labour and freight, end if the unit is moved, and their term depends on the type of occupancy:

ModelsTermTermsDocument
HE12M2 · HE17M2 · HE17A2 · HE18FA25 yearsparts; units bought online excluded unless installed by a dealerPWOHEHUB (06/2022)
DV065 · DV090 · DV1206 yearsparts; units bought online excluded unless installed by a licensed dealerPWODVDHB (06/2022)
HS1122 · HS2529 · HS11 · HS22 · HS295 yearsparts, cylinder excluded; 5 years from installation or 63 months from manufacture, whichever comes firstHS certificate (2/15)
DV070 · DV098 · DV1555 years“5 year parts” printed on the sheet; terms not publishedSS-DV sheets (2014-2015)
HE12M · HE17M10 yearshumidifier parts, original owner-occupant; 1 year on accessories sold separatelyHE warranty (2/15)

Owner-occupant: terms shown as each certificate states them.

For a claim, the PWOHEHUB certificate asks you to go through a licensed contractor. The arbitration clauses of both 2022 certificates do not apply to Québec residents.

07 Rebates and certifications

No program we checked covers these units

We checked each program on its own website on October 14, 2026. Better to know before you sign.

Hydro-Québec LogisVert

The participation guide (version 1.10 of September 15, 2026) covers heat pumps, insulation and other measures; no humidifier or dehumidifier.

Not eligible

Rénoclimat

List of eligible measures (quebec.ca, updated October 13, 2026): no humidifier or dehumidifier named.

Not eligible

ENERGY STAR

Certifies whole-home dehumidifiers, but no Clean Comfort model is on its list (dataset of October 8, 2026). No category for humidifiers.

Not certified

Énergir · Hilo

Énergir rebates smart thermostats; Hilo targets thermostats. Nothing for these units.

Not eligible

Federal programs

The Canada Greener Homes Grant is closed.

Closed

08 The brand

Who is behind Clean Comfort

The cleancomfort.com website carries the Daikin Comfort Technologies North America name, and the 2020 sheets carry Goodman Manufacturing’s. The 2022 warranty certificates (PWOHEHUB and PWODVDHB) are issued by Daikin Comfort Technologies Manufacturing. The site currently presents the HE12M2, HE17M2, HE12A2, HE17A2, HE18FM2, HE18FA2, HS1122 and HS2529 humidifiers and the DV065, DV090 and DV120 dehumidifiers.

Evaporative24 V bypass or 120 V fan, replaceable pad
Steamelectrode cylinder, 120, 208 or 240 V
Dehumidificationducted whole-home units, MERV 11 filter

10 FAQ

Common questions about Clean Comfort

Who makes Clean Comfort units?

The cleancomfort.com website carries the Daikin Comfort Technologies North America name, and the 2022 warranty certificates are issued by Daikin Comfort Technologies Manufacturing. The 2020 sheets carry Goodman Manufacturing’s name.

Bypass or fan-powered: what is the difference?

A bypass model links the supply and the return with a duct and only uses its 24 V valve (7 W on the HE12M2 and HE17M2). The HE18FA2 has its own fan on 120 V (1 A) and produces 18 US gal/day, for a published volume of 24,000 cu ft.

Manual or automatic?

M models are set by hand. A and FA models come with the DV6062A1001 automatic control, according to Clean Comfort’s website.

When should I pick a steam humidifier?

When you need more than 18 US gal/day, or when an evaporative unit does not suit the installation. The HS1122 gives up to 22.1 US gal/day at 240 V and the HS2529 up to 29.3 US gal/day at 240 V, per the SS-HS-HUM sheet.

Can a steam humidifier run on 120 V?

Yes, the HS1122-120/240V: 11.1 US gal/day at 120 V, 12 A, 15 A fuse. The HS2529 needs 208 or 240 V.

Which humidifier for my home’s size?

Clean Comfort publishes a maximum volume for the HE12A2 (16,000 cu ft), HE17A2 (20,000 cu ft) and HE18FA2 (24,000 cu ft), and an area for the HE12M and HE17M (1,200 and 1,650 sq ft in an average-construction home). For the other models, we assess on site.

Which dehumidifier for a basement?

Capacity drops with temperature: the DV120 removes 120 pints/day at 80 °F, 88 at 70 °F and 63 at 60 °F. Clean Comfort publishes an area for three models: DV070 (1,800 sq ft), DV098 (2,300 sq ft) and DV155 (3,500 sq ft).

What upkeep should I plan for?

A pad for the evaporative units (HE22E1003 or HE26E1004 on the 2nd generation), an HSP-2573990 cylinder for the HS1122 and HS2529, and a MERV 11 filter for the dehumidifiers. The 2nd-generation intervals are not published.

What does the warranty cover?

Parts: 5 years on the 2nd-generation evaporative humidifiers and 6 years on the DV065, DV090 and DV120 in an owner-occupied home; 1 year in a rental or a business. Clean Comfort does not cover labour. Details in section 06.

Is there a rebate for these units?

No. As of October 14, 2026, neither LogisVert, Rénoclimat, Énergir, Hilo nor a federal program covers humidifiers or dehumidifiers, and no Clean Comfort model is ENERGY STAR certified.

Why are some models missing from Clean Comfort’s website?

The site shows the current lineup. The HE12M, HE17M, HS11-120, HS22-240, HS29-208, DV070, DV098 and DV155 we offer come from earlier sheets (2014 and 2015). We confirm the available model in the quote.

How much does an installation cost?

Price on quotation: we assess the installation at your home, free of charge, then we send you the price.

11 Next step

We assess your setup at your home, then we send you a price

The in-home estimate is free. Choosing between bypass, fan and steam depends on the room around the furnace and the water, drain and electrical circuit available.

  • Showroom1370, rue Joliot-Curie, local 712, Boucherville
  • HoursMonday to Thursday 8 a.m. to 6 p.m. · Friday 8 a.m. to 4 p.m.
  • RBQ5645-9605-01 · subclasses 15.8, 15.10 and 16
  • AreaMontréal, Laval, Longueuil, South Shore and North Shore

12 Sources

Documents consulted

  1. Clean Comfort, cleancomfort.com (lineup, warranties, colours), consulted October 14, 2026.
  2. Clean Comfort spec sheets SS-HE12M2_HE17M2, SS-HE12A2_HE17A2 and SS-HE18FA2_HE18FM2 (rev. 11/20).
  3. Clean Comfort spec sheets SS-HE12-B and SS-HE17-B (rev. 12/15); 1st-generation HE warranty (2/15).
  4. Clean Comfort SS-HS-HUM sheet (rev. 5/18); PM-CCLINE 12-15 brochure; HS warranty certificate (2/15).
  5. Clean Comfort sheets SS-DV065, SS-DV090, SS-DV120 (10/20), SS-DV070, SS-DV155 (2/14), SS-DV098 (10/15).
  6. Clean Comfort warranty certificates PWOHEHUB (06/2022) and PWODVDHB (06/2022).
  7. ENERGY STAR certified dehumidifiers dataset (mgiu-hu4z), updated October 8, 2026.
  8. Hydro-Québec, LogisVert participation guide, version 1.10 of September 15, 2026.
  9. Government of Québec, Rénoclimat, page updated October 13, 2026; Énergir, Hilo and Natural Resources Canada, consulted October 14, 2026.

Price on quotation · free in-home estimate

The Clean Comfort shop

All our Clean Comfort products, right below.

Bypass, fan-powered and steam humidifiers and whole-home dehumidifiers: filter, then open the product page. Price on quotation.

Clean Comfort