Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
ELIOS e-Multi heat pump · 2 heads
Two rooms, one compressor: the 2-head e-Multi comes on four outdoor units.
From 18,000 to 48,000 BTU/h: the only head count offered on all four e-Multi compressors. The ELIOS table lists 7 to 14 two-head combinations depending on the compressor.
Two heads in four numbers
TAB_E_MZCBEX (March 2026), SUB_E_XHSA (07.26).
The essentials
Two heads: the widest freedom of choice at ELIOS.
What the ELIOS table allows with two heads, compressor by compressor.
Two heads connect to all four outdoor units: 18,000, 27,000, 36,000 and 48,000.
Live collection; TAB_E_MZCBEXTwo-head combinations listed for the 18,000, 27,000, 36,000 and 48,000.
TAB_E_MZCBEX, p. 3-6On the 48,000, the two heads can range from 6,000 to 33,000; the 36,000 does not take the 33,000.
TAB_E_MZCBEXTwo 9,000 heads on the 18,000: 0.75 + 0.75 = 1.5, a 100% connection.
TAB_E_MZCBEX, p. 3Maximum line per head: 30 m on the 18,000, 35 m on the others.
SUB_E_XHSA*, p. 1LogisVert depending on the compressor chosen, list of Oct. 25, 2026.
Hydro-Québec listMaximum outdoor unit level, from the 18,000 to the 48,000.
SUB_E_XHSA*, p. 2Two rooms, one unit outside and a single electrical connection at the panel.
SUB_E_XHSA*Your 2 rooms
Two rooms: pick the compressor and each head’s size.
The planner only offers two-head combinations listed in the ELIOS table.
Our 2-head e-Multi systems, right below.
Four listings, one per compressor.
Everything to know
All about the 2-head e-Multi systems.
Each compressor’s certified cold data, outdoor noise, the heads and their score, the electrical data.
Every model, side by side
The 2-head e-Multi systems, side by side.
Same heads, four compressors: the difference is in cold-weather capacity.
| Model | Heat at −8 °C | Max at −15 °C | Coldest certified point | SEER2 | HSPF2 (V) | Sound | LogisVert | Certification |
|---|---|---|---|---|---|---|---|---|
| e-Multi · 18,000 BTU/h · 2 headsEXHSA1832AN1 | 16,000 BTU/h | 13,500 BTU/h | −25 °C · 7,000 BTU/h | 23 | 7.7 | 60 dB(A) outdoor | $1,920 | AHRI 216505500 · ENERGY STAR 3891349, cold climate |
| e-Multi · 27,000 BTU/h · 2 headsEXHSA2742AV1 | 23,600 BTU/h | 19,000 BTU/h | −25 °C · 11,800 BTU/h | 23 | 7.1 | 61 dB(A) outdoor | $2,832 | AHRI 216046639 · ENERGY STAR 3799027, cold climate |
| e-Multi · 36,000 BTU/h · 2 headsEXHSA3652AV1 | 31,000 BTU/h | 26,000 BTU/h | −25 °C · 20,000 BTU/h | 23.1 | 7.5 | 63 dB(A) outdoor | $3,720 | AHRI 216046642 · ENERGY STAR 3799030, cold climate |
| e-Multi · 48,000 BTU/h · 2 headsEXHSA4862AV1 | 36,800 BTU/h | 36,000 BTU/h | −25 °C · 20,000 BTU/h | 21.3 | 7.7 | 65 dB(A) outdoor | $4,416 | AHRI 216046645 · ENERGY STAR 3799033, cold climate |
Heat at −8 °C, maximum at −15 °C and coldest point: NEEP registry (ashp.neep.org), read by AHRI number on Oct. 14, 2026. SEER2 and HSPF2 region V: same source. LogisVert amounts: Hydro-Québec’s list of eligible heat pumps, Oct. 25, 2026. Sound: ELIOS technical documents. A dash means “not published”.
The thermometer
What each compressor certifies in the cold.
Total system capacity, shared between the heads, per NEEP.
The sound meter
The outdoor compressor, on the Québec.ca scale.
Maximum outdoor unit level per ELIOS. The heads have their own levels, in the heads table.
Tech corner
The four e-Multi compressors, one line each.
SUB_E_XHSA submittals (07.26). All 208-230 V, R-454B, flared connections, 7.5 m pre-charged per connection.
| Outdoor unit | Max heads | Total / per-head lines | Height | Outdoor sound | MCA / protection | Heats down to (ELIOS) |
|---|---|---|---|---|---|---|
| 18,000 · EXHSA1832AN1 | 3 | 60 / 30 m | 15 m (10 m between heads) | 60 dB(A) | 16 / 20 A | −25 °C |
| 27,000 · EXHSA2742AV1 | 4 | 80 / 35 m | 15 m (10 m between heads) | 61 dB(A) | 23 / 25 A | −25 °C |
| 36,000 · EXHSA3652AV1 | 5 | 80 / 35 m | 15 m (10 m between heads) | 63 dB(A) | 30.5 / 35 A | −25 °C |
| 48,000 · EXHSA4862AV1 | 6 | 80 / 35 m | 15 m (10 m between heads) | 65 dB(A) | 40 / 45 A | −25 °C |
The heads
The wall heads and their score.
The score, not the BTU, decides whether a combination is allowed. EMC heads, ELIOS I1 submittals (11.25).
| Wall head | Score | Width | Sound (low–turbo) | Lines |
|---|---|---|---|---|
| 6,000 · EWHMA06 | 0.5 | 729 mm | 24–42 dB(A) | 1/4 – 3/8 in |
| 9,000 · EWHMA09 | 0.75 | 802 mm | 24–44 dB(A) | 1/4 – 3/8 in |
| 12,000 · EWHMA12 | 1 | 802 mm | 22.5–44.7 dB(A) | 1/4 – 3/8 in |
| 18,000 · EWHMA18 | 1.5 | 1,082 mm | 24.5–54.5 dB(A) | 1/4 – 1/2 in |
| 24,000 · EWHMA24 | 2 | 1,082 mm | 34.5–54.5 dB(A) | 3/8 – 5/8 in |
| 33,000 · EWHMA33 | 3 | 1,259 mm | 29.5–56 dB(A) | 3/8 – 3/4 in |
Did you know
What the e-Multi manual says and the box does not.
Tap a card to flip it.
LogisVert · Hydro-Québec
LogisVert on the 2-head systems: by compressor.
4 of the 4 listings on this page appear on Hydro-Québec’s list of eligible heat pumps (Oct. 25, 2026). The amount follows the certified heating capacity at −8 °C, size by size.
| Model | Capacity at −8 °C | Rate | Amount |
|---|---|---|---|
| e-Multi · 48,000 BTU/h · 2 heads | 36,800 BTU/h | $120 per 1,000 BTU/h, cold climate | $4,416 |
| e-Multi · 36,000 BTU/h · 2 heads | 31,000 BTU/h | $120 per 1,000 BTU/h, cold climate | $3,720 |
| e-Multi · 27,000 BTU/h · 2 heads | 23,600 BTU/h | $120 per 1,000 BTU/h, cold climate | $2,832 |
| e-Multi · 18,000 BTU/h · 2 heads | 16,000 BTU/h | $120 per 1,000 BTU/h, cold climate | $1,920 |
How Hydro-Québec computes it
The amount follows the certified heating capacity at −8 °C: $120 per 1,000 BTU/h for a cold-climate ENERGY STAR heat pump, $50 for a standard ENERGY STAR heat pump.
- Outdoor unit of 12,000 BTU/h or more.
- Capped at 100% of the cost of the work.
- Apply within 9 months of the installation.
Source: Hydro-Québec, LogisVert participation guide, residential customers, version 1.10 of September 15, 2026. Have Hydro-Québec confirm your case. Our LogisVert page.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. The amount shown is indicative: only Hydro-Québec confirms the aid granted.
Questions
Questions about the 2-head ELIOS systems.
Two single-zone units or one 2-head system?
A 2-head system puts one unit outside and one circuit at the panel. Two single-zone units stay independent. We compare both on site, with the LogisVert amounts of each option.
Which compressor for two rooms?
The 18,000 can be enough for two bedrooms; for a living room and a kitchen, a 27,000 or 36,000 leaves more margin in the cold. The planner shows what each certifies at −8 and −15 °C.
Can a third head be added later?
Only if the compressor accepts it and the combination is in the table: in three heads, the 18,000 only takes 6,000 and 9,000 units. Think about it when choosing.
What happens if a head detects a leak?
The head’s fan runs to disperse the refrigerant, an automatic shut-off valve isolates the circuit and the compressor stops, per the 2026 e-Multi brochure.
What warranty on an e-Multi?
ELIOS publishes 1 year on parts and 5 years on the compressor, with optional 10-year coverage. ELIOS publishes no labour warranty.
AirGreen × ELIOS · your project
2 rooms to heat and cool? We draw the plan with you.
We visit each room, choose the heads, check the combination with the ELIOS tool and price the line installation.
AirGreen · Air Conditioning & Heating
RBQ licence 5645-9605-01, subclasses 15.8 (ventilation), 15.10 (refrigeration) and 16 (electrical).
Free on-site estimate across Greater Montreal: Montreal, Laval, Longueuil, the North Shore and the South Shore.
Gas, oil and hydronic work is done by a partner who holds the required licence.
Sources checked on Oct. 26, 2026
- ELIOS, e-Multi outdoor unit submittals SUB_E_XHSA18, 27, 36 and 48 (revision 2, printed 07.26), eliosprotech.com.
- ELIOS, multi-zone combination table TAB_E_MZCBEX, revision 3 (March 2026).
- ELIOS, e-Multi brochures (Elios_e-Multi_202509 V02 and 202603 V03).
- ELIOS, ISM_E_XHSXHZ installation manual (pre-charge, lengths, defrost, automatic correction).
- ELIOS, wall head submittals SUB_E_WHMA06 to 33 (I1, 11.25) and “Did you know” bulletin DYK_E_042826.
- NEEP, Cold Climate Air Source Heat Pump List, ashp.neep.org, records read by AHRI number on Oct. 14, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps dataset (data.energystar.gov, w7cv-9xjt), Canadian market, read Oct. 14, 2026.
- Hydro-Québec, LogisVert eligible heat pump list, owner, existing home, file of Oct. 25, 2026 (ELIOS rows identical to Oct. 14).
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, Sept. 15, 2026.
- Québec.ca, “Mesure du bruit”, updated June 16, 2022 (dBA sound scale).
- ENERGY STAR, “Properly Sized Room Air Conditioners”, energystar.gov (sizing chart), read Oct. 26, 2026.
Amounts shown are estimates; only the responsible organizations confirm the aid granted. Product availability is confirmed at the time of the quotation.