Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
YORK 4-zone heat pumps: six outdoor units, from 30,000 to 42,000 BTU/h, for four rooms
For four rooms, six outdoor units: the W and the M at 30,000, 36,000 and 42,000 BTU/h, with 47 combinations of four heads per series. The 36,000 M and both 30,000 units stop at four.
At 4 heads, the number of combinations YORK publishes, unit by unit.
YORK 2020 catalogue, “Possible outdoor / indoor combinations” charts.
Every 4-head combination, unit by unit.
Pick the outdoor unit size: here are the head sizes YORK allows on it, for the W Series and the M Series.
Head sizes in thousands of BTU/h (9 = 9,000 BTU/h); after the = sign, the sum of nominal sizes in BTU/h. Output stays that of the outdoor unit: YORK asks that the outdoor unit be sized for the whole house’s load, and each head for its own room. We don’t install a combination that is not on YORK’s list.
Four heads at most: the 30,000 W and M, the 36,000 M.
| Item | W Series · 30,000 BTU/h | M Series · 30,000 BTU/h | M Series · 36,000 BTU/h |
|---|---|---|---|
| Outdoor model | DHW30CMB21SAHRI 8581966 | DHM30CMB21SAHRI 8581962 | DHM36CMB21SAHRI 8578493 |
| Max. heads | 4 | 4 | 4 |
| SEER · EER · HSPF | 21 · 12 · 10.2 | 16 · 7.3 · 8.2 | 16 · 7.9 · 8.2 |
| Rated cooling · rated heating at 8.3 °C | 29,000 · 30,400 BTU/h | 29,000 · 30,400 BTU/h | 34,000 · 35,800 BTU/h |
| Heating capacity, min. to max. | 7,500 to 36,000 BTU/h | 7,500 to 36,000 BTU/h | 10,663 to 40,944 BTU/h |
| Heats down to | −20 °C | −15 °C | −15 °C |
| Cooling down to (outdoor) | −18 °C | −5 °C | −5 °C |
| Min. circuit ampacity (MCA) · max. overcurrent protection (MOCP) | 19 A · 30 A | 26 A · 45 A | 28 A · 45 A |
| Outdoor unit (W × H × D) | 38 × 31 × 17 in.145 lb · 59 dB(A) | 36 × 31 × 17 in.153 lb · 56 dB(A) | 36 × 31 × 17 in.161 lb · 59 dB(A) |
| Total line length | 245 ft | 245 ft | 245 ft |
| To the farthest head | 82 ft | 66 ft | 66 ft |
| Height difference (up or down) | 49 ft | 33 ft | 49 ft |
| Factory charge | 98.76 oz | 77.6 oz | 102.29 oz |
These units also take 4 heads; their full data is on the page of their maximum head count:
The four-head system, designed by YORK, installed by AirGreen.
AirGreen picks the outdoor unit and each head’s size with you within YORK’s combinations, then installs the 4 heads.
What YORK brings
- 6 outdoor unitsW and M, from 30,000 to 42,000 BTU/h.
- 94 published combinationsAt 4 heads, W and M together.
- Four head typesWall, cassette,
floor-ceiling and ducted; our listings come with wall heads.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the insulation, the electrical service and the refrigerant line route.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: one head per room, 4 in all, in a combination YORK allows.
All four-head listings, right below.
One listing per outdoor unit, with wall heads and its AHRI number; other heads are quoted on request.
What is specific to 4-head systems.
- The 30,000 BTU/h W allows 82 ft to the farthest head and 49 ft of height difference, versus 66 ft and 33 ft for the 30,000 M.
- The 30,000 BTU/h M needs the largest circuit at this size: MCA 26 A and MOCP 45 A, versus 19 A and 30 A for the W.
LogisVert: none of our 4-head YORK systems qualifies.
None of the 6 AHRI numbers on our 6 listings is on
What people ask us about 4-head systems.
Which YORK outdoor units serve four rooms?
The W and M at 30,000, 36,000 and 42,000 BTU/h. The 30,000 W and M, and the 36,000 M, stop at four heads.
Four heads on a 30,000 BTU/h unit, is that possible?
Yes, in four combinations: 4 × 9,000, 3 × 9,000 + 12,000, 3 × 9,000 + 18,000 and 2 × 9,000 + 2 × 12,000 BTU/h.
W or M at 30,000 BTU/h with four heads?
The W is rated 21 SEER and 12 EER, the M 16 SEER and 7.3 EER; the W heats down to −20 °C, the M to −15 °C. The allowed combinations are the same.
Do YORK four-zone systems qualify for LogisVert?
No: no AHRI number on our 6 four-head listings is on
Your 4 rooms, one YORK outdoor unit, installed by AirGreen.
At the free visit, we check whether a 30,000 BTU/h unit is enough for your four heads or a 36,000 or 42,000 is needed.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): M and Wmulti-zone , outdoor units (pp. 24 and 31), indoor units (pp. 23, 25 to 28 and 32 to 35), possible combinations (pp. 29, 30, 36 and 37); copy in our documents, re-read October 26, 2026. - YORK, M Series (
PUBL-8258v2 ) and W Series (PUBL-8259v2 ) brochures, July 2019: maximum zones per outdoor unit; copies in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
- airgreen.ca product pages: outdoor units, head counts and AHRI numbers we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.