YORK 3-zone heat pumps: eight outdoor units and every three-head combination they take
For three rooms, eight outdoor units: the W and the M from 24,000 to 42,000 BTU/h. YORK publishes 65 combinations of three heads per series; the 24,000 BTU/h units stop at three heads.
At 3 heads, the number of combinations YORK publishes, unit by unit.
YORK 2020 catalogue, “Possible outdoor / indoor combinations” charts.
Every 3-head combination, unit by unit.
Pick the outdoor unit size: here are the head sizes YORK allows on it, for the W Series and the M Series.
Head sizes in thousands of BTU/h (9 = 9,000 BTU/h); after the = sign, the sum of nominal sizes in BTU/h. Output stays that of the outdoor unit: YORK asks that the outdoor unit be sized for the whole house’s load, and each head for its own room. We don’t install a combination that is not on YORK’s list.
The 24,000 BTU/h units: three heads at most.
| Item | W Series · 24,000 BTU/h | M Series · 24,000 BTU/h |
|---|---|---|
| Outdoor model | DHW24CMB21SAHRI 8581793 | DHM24CMB21SAHRI 8581777 |
| Max. heads | 3 | 3 |
| SEER · EER · HSPF | 20.5 · 9.5 · 10.2 | 16 · 8.2 · 8.2 |
| Rated cooling · rated heating at 8.3 °C | 26,000 · 29,000 BTU/h | 26,000 · 29,000 BTU/h |
| Heating capacity, min. to max. | 7,500 to 35,000 BTU/h | 7,500 to 35,000 BTU/h |
| Heats down to | −20 °C | −15 °C |
| Cooling down to (outdoor) | −18 °C | −5 °C |
| Min. circuit ampacity (MCA) · max. overcurrent protection (MOCP) | 21 A · 35 A | 20 A · 30 A |
| Outdoor unit (W × H × D) | 38 × 31 × 17 in.153 lb · 59 dB(A) | 37 × 28 × 16 in.135 lb · 56 dB(A) |
| Total line length | 197 ft | 245 ft |
| To the farthest head | 66 ft | 66 ft |
| Height difference (up or down) | 33 ft | 33 ft |
| Factory charge | 77.6 oz | 77.6 oz |
These units also take 3 heads; their full data is on the page of their maximum head count:
The three-head system, designed by YORK, installed by AirGreen.
AirGreen picks the outdoor unit and each head’s size with you within YORK’s combinations, then installs the 3 heads.
What YORK brings
- 8 outdoor unitsW and M, from 24,000 to 42,000 BTU/h.
- 130 published combinationsAt 3 heads, W and M together.
- Four head typesWall, cassette,
floor-ceiling and ducted; our listings come with wall heads.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the insulation, the electrical service and the refrigerant line route.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: one head per room, 3 in all, in a combination YORK allows.
All three-head listings, right below.
One listing per outdoor unit, with wall heads and its AHRI number; other heads are quoted on request.
What is specific to 3-head systems.
- At three heads, the 21,000 BTU/h head appears only from the 36,000 BTU/h unit up.
- On the 24,000 BTU/h unit, a single 18,000 head is allowed, with two 9,000 heads.
LogisVert: none of our 3-head YORK systems qualifies.
None of the 8 AHRI numbers on our 8 listings is on
What people ask us about 3-head systems.
Which YORK outdoor units serve three rooms?
The W and M at 24,000, 30,000, 36,000 and 42,000 BTU/h. The 24,000 BTU/h units stop at three heads.
Can I connect three 12,000 BTU/h heads to a 24,000 unit?
Yes: 12,000 + 12,000 + 12,000 is among the five three-head combinations listed for the 24,000 BTU/h unit.
From what size can a three-head system include a 24,000 BTU/h head?
From the 36,000 BTU/h unit up, with two 9,000 or 12,000 heads, for example.
Do YORK three-zone systems qualify for LogisVert?
No: no AHRI number on our 8 three-head listings is on
Your 3 rooms, one YORK outdoor unit, installed by AirGreen.
At the free visit, we check whether the 24,000 BTU/h W (197 ft of total line length) is enough, or the 24,000 M or the 30,000 W (245 ft each) is needed for your three rooms.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): M and Wmulti-zone , outdoor units (pp. 24 and 31), indoor units (pp. 23, 25 to 28 and 32 to 35), possible combinations (pp. 29, 30, 36 and 37); copy in our documents, re-read October 26, 2026. - YORK, M Series (
PUBL-8258v2 ) and W Series (PUBL-8259v2 ) brochures, July 2019: maximum zones per outdoor unit; copies in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
- airgreen.ca product pages: outdoor units, head counts and AHRI numbers we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.