YORK 2-zone heat pumps: ten outdoor units, from 18,000 to 42,000 BTU/h, for two rooms
For two rooms, all ten YORK outdoor units fit: W or M, from 18,000 to 42,000 BTU/h. YORK publishes 44 combinations of two heads for each series, from 9,000 + 9,000 to 24,000 + 24,000 BTU/h.
At 2 heads, the number of combinations YORK publishes, unit by unit.
YORK 2020 catalogue, “Possible outdoor / indoor combinations” charts.
Every 2-head combination, unit by unit.
Pick the outdoor unit size: here are the head sizes YORK allows on it, for the W Series and the M Series.
Head sizes in thousands of BTU/h (9 = 9,000 BTU/h); after the = sign, the sum of nominal sizes in BTU/h. Output stays that of the outdoor unit: YORK asks that the outdoor unit be sized for the whole house’s load, and each head for its own room. We don’t install a combination that is not on YORK’s list.
The 18,000 BTU/h units: two heads, no more.
| Item | W Series · 18,000 BTU/h | M Series · 18,000 BTU/h |
|---|---|---|
| Outdoor model | DHW18CMB21SAHRI 8581781 | DHM18CMB21SAHRI 8581773 |
| Max. heads | 2 | 2 |
| SEER · EER · HSPF | 22 · 12.5 · 9 | 16 · 10.2 · 8.2 |
| Rated cooling · rated heating at 8.3 °C | 18,000 · 19,000 BTU/h | 18,000 · 19,000 BTU/h |
| Heating capacity, min. to max. | 8,530 to 22,600 BTU/h | 8,530 to 22,600 BTU/h |
| Heats down to | −20 °C | −15 °C |
| Cooling down to (outdoor) | −18 °C | −5 °C |
| Min. circuit ampacity (MCA) · max. overcurrent protection (MOCP) | 15 A · 25 A | 13 A · 20 A |
| Outdoor unit (W × H × D) | 38 × 28 × 16 in.114 lb · 56 dB(A) | 35 × 24 × 15 in.95 lb · 56 dB(A) |
| Total line length | 66 ft | 66 ft |
| To the farthest head | 33 ft | 33 ft |
| Height difference (up or down) | 33 ft | 16 ft |
| Factory charge | 56.43 oz | 47.61 oz |
These units also take 2 heads; their full data is on the page of their maximum head count:
The two-head system, designed by YORK, installed by AirGreen.
AirGreen picks the outdoor unit and each head’s size with you within YORK’s combinations, then installs the 2 heads.
What YORK brings
- 10 outdoor unitsW and M, from 18,000 to 42,000 BTU/h.
- 88 published combinationsAt 2 heads, W and M together.
- Four head typesWall, cassette,
floor-ceiling and ducted; our listings come with wall heads.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the insulation, the electrical service and the refrigerant line route.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: one head per room, 2 in all, in a combination YORK allows.
All two-head listings, right below.
One listing per outdoor unit, with wall heads and its AHRI number; other heads are quoted on request.
What is specific to 2-head systems.
- With two heads, YORK lists only 9,000 and 12,000 BTU/h heads on the 18,000 BTU/h units; it takes 24,000 BTU/h to connect an 18,000 head.
- The 18,000 BTU/h M allows 16 ft of height difference, the W 33 ft.
LogisVert: none of our 2-head YORK systems qualifies.
None of the 10 AHRI numbers on our 10 listings is on
What people ask us about 2-head systems.
Which YORK outdoor units serve two rooms?
All ten: the W and M at 18,000, 24,000, 30,000, 36,000 and 42,000 BTU/h. The 18,000 BTU/h units stop at two heads.
Can I put two 9,000 BTU/h heads on a 42,000 unit?
No: YORK does not list that combination for the 42,000 BTU/h unit. It is allowed from 18,000 to 36,000 BTU/h.
What are the largest heads in a two-head system?
Two 24,000 BTU/h heads, allowed on the 36,000 and 42,000 BTU/h units; output stays that of the outdoor unit.
Do YORK two-zone systems qualify for LogisVert?
No: no AHRI number on our 10 two-head listings is on
Your 2 rooms, one YORK outdoor unit, installed by AirGreen.
At the free visit, we check whether your two rooms fit an 18,000 BTU/h unit or need a 24,000 to take an 18,000 head.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): M and Wmulti-zone , outdoor units (pp. 24 and 31), indoor units (pp. 23, 25 to 28 and 32 to 35), possible combinations (pp. 29, 30, 36 and 37); copy in our documents, re-read October 26, 2026. - YORK, M Series (
PUBL-8258v2 ) and W Series (PUBL-8259v2 ) brochures, July 2019: maximum zones per outdoor unit; copies in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
- airgreen.ca product pages: outdoor units, head counts and AHRI numbers we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.