YORK central heat pumps: YH5 or HH8, what sets them apart at the same tonnage
At −15 °C (5 °F), the HH8 keeps 72 to 82% of its certified heating capacity at 8.3 °C; the YH5 LX keeps 49 to 55%. The rest shows in your yard and basement: footprint, weight, electrical circuit, line sets.
Where to start? Pick what matters to you.
The HH8 systems are ENERGY STAR
With its side discharge, the HH8 is the shallowest central unit in our catalogue at 2, 3 and 5 tons. Clearances are not in the YORK documents we read: we check them at the visit.
Compare dimensionsAt 1.5 tons, our catalogue only has the YH5 LX: our HH8 starts at 2 tons. At 4 tons, our catalogue has the YH548; YORK also sells the HH860 for 4 and 5 tons with a capacity switch, but our listing shows it at 5 tons.
See the YH5 LXThe HH8 gets LogisVert’s
The YORK documents we read give no per-model sound level. YORK claims “as low as 54 dBA” for the HH8 and, for the YH5, “as low as 69 dBA” in its technical guide and “76 dBA or lower” on its product page, with no test conditions.
The two YORK central systems in our catalogue, two ways to heat.
Same brand, same indoor family; what changes is the compressor, the discharge direction and cold-weather performance.
YH5 LXYORK Efficiency tier
Matched systems5
Tonnage1.5 to 5 tons
Compressor
HH8YORK Premium side-discharge tier
Matched systems3
Tonnage2 to 5 tons
CompressorInverter-driven twin rotary, variable speed
DischargeSide
Certified SEER219.0
ENERGY STAR cold climateYes, all
LogisVert$2,136 to $4,440
See the HH8 →
The YH5 and the HH8 side by side, from performance to dimensions.
At 2 and 3 tons both families pair with the same JHE air handler; at 5 tons our listings pair two different indoor units. The “Difference” column reads HH8 minus YH5.
| Item | YH5 LX | HH8 | Difference |
|---|---|---|---|
| Certified pairing | YH524E2S11 + JHE24B5AC2SS1 | HH824E2S11 + JHE24B5AC2SS1 | Same indoor unit |
| AHRI number | 214424696 | 214396076 | |
| Compressor | Twin rotary, variable speed | ||
| Discharge | Top | Side | |
| Heating capacity at 8.3 °C (47 °F) | 22,800 BTU/h | 23,000 BTU/h | +200 |
| Heating capacity at −8.3 °C (17 °F) | 14,400 BTU/h | 17,800 BTU/h | +3,400 |
| Heating capacity at −15 °C (5 °F) | 11,200 BTU/h | 18,300 BTU/h | +7,100 |
| Max. output at −25 °C (−13 °F) | Not published: not on the NEEP list as of Oct. 27, 2026 | 11,800 BTU/h (NEEP) | |
| COP at −15 °C | 2.0 | 2.0 | |
| SEER2 · EER2 | 15.2 · 12.0 | 19.0 · 12.0 | +3.8 SEER2 |
| HSPF2 (ENERGY STAR) | 7.8 | 9.5 | +1.7 |
| ENERGY STAR cold climate | No | Yes | |
| Dimensions A × B × C (in.) | 30 × 29 1/4 × 29 1/4 | 29 1/2 × 35 3/7 × 13 2/5 | |
| Operating weight | 162 lb | 116.8 lb | −45.2 lb |
| Min. circuit ampacity (MCA) · max. overcurrent protection | 15.0 A · 25 A | 22 A · 25 A | |
| Liquid · vapour lines (in.) | 3/8 · 3/4 | 3/8 · 5/8 | |
| Factory charge (15 ft) · per foot | 5 lb 4 oz · 0.57 oz/ft | 5 lb 1 oz · 0.54 oz/ft | |
| LogisVert ( | $720 | $2,136 | +$1,416 |
Here the HH8’s certified capacity at −15 °C exceeds its figure at −8.3 °C: these are the values ENERGY STAR publishes, shown as they are.
| Item | YH5 LX | HH8 | Difference |
|---|---|---|---|
| Certified pairing | YH536E2S11 + JHE36B5CD2SS1 | HH836E2S11 + JHE36B5CD2SS1 | Same indoor unit |
| AHRI number | 214427016 | 215853295 | |
| Compressor | Twin rotary, variable speed | ||
| Discharge | Top | Side | |
| Heating capacity at 8.3 °C (47 °F) | 31,800 BTU/h | 31,800 BTU/h | 0 |
| Heating capacity at −8.3 °C (17 °F) | 21,000 BTU/h | 28,400 BTU/h | +7,400 |
| Heating capacity at −15 °C (5 °F) | 17,600 BTU/h | 26,000 BTU/h | +8,400 |
| Max. output at −25 °C (−13 °F) | Not published: not on the NEEP list as of Oct. 27, 2026 | 16,500 BTU/h (NEEP) | |
| COP at −15 °C | 2.0 | 2.0 | |
| SEER2 · EER2 | 15.2 · 11.0 | 19.0 · 11.0 | +3.8 SEER2 |
| HSPF2 (ENERGY STAR) | 8.1 | 9.0 | +0.9 |
| ENERGY STAR cold climate | No | Yes | |
| Dimensions A × B × C (in.) | 36 1/4 × 29 1/4 × 29 1/4 | 34 4/9 × 43 1/3 × 17 5/7 | |
| Operating weight | 176 lb | 185.2 lb | +9.2 lb |
| Min. circuit ampacity (MCA) · max. overcurrent protection | 20.4 A · 30 A | 30 A · 35 A | |
| Liquid · vapour lines (in.) | 3/8 · 3/4 | 3/8 · 3/4 | |
| Factory charge (15 ft) · per foot | 5 lb 1 oz · 0.57 oz/ft | 7 lb 7 oz · 0.57 oz/ft | |
| LogisVert ( | $1,050 | $3,408 | +$2,358 |
| Item | YH5 LX | HH8 | Difference |
|---|---|---|---|
| Certified pairing | YH560E2S11 + JHE60D5CH2SS1 | HH860E2S11 + JHE60C5CH2SS1 | Different indoor units |
| AHRI number | 214424699 | 215853276 | |
| Compressor | Twin rotary, variable speed | ||
| Discharge | Top | Side | |
| Heating capacity at 8.3 °C (47 °F) | 56,500 BTU/h | 53,500 BTU/h | −3,000 |
| Heating capacity at −8.3 °C (17 °F) | 38,500 BTU/h | 37,000 BTU/h | −1,500 |
| Heating capacity at −15 °C (5 °F) | 29,800 BTU/h | 38,500 BTU/h | +8,700 |
| Max. output at −25 °C (−13 °F) | Not published: not on the NEEP list as of Oct. 27, 2026 | 25,400 BTU/h (NEEP) | |
| COP at −15 °C | 2.1 | 2.0 | |
| SEER2 · EER2 | 15.2 · 11.7 | 19.0 · 11.7 | +3.8 SEER2 |
| HSPF2 (ENERGY STAR) | 7.8 | 9.0 | +1.2 |
| ENERGY STAR cold climate | No | Yes | |
| Dimensions A × B × C (in.) | 39 1/2 × 35 1/4 × 31 3/4 | 57 1/2 × 38 2/5 × 13 | |
| Operating weight | 255 lb | 244.7 lb | −10.3 lb |
| Min. circuit ampacity (MCA) · max. overcurrent protection | 33.7 A · 50 A | 37 A · 45 A | |
| Liquid · vapour lines (in.) | 3/8 · 1 1/8 (adapter, 7/8 valve) | 3/8 · 7/8 | |
| Factory charge (15 ft) · per foot | 10 lb 5 oz · 0.67 oz/ft | 11 lb · 0.6 oz/ft | |
| LogisVert ( | $1,925 | $4,440 | +$2,515 |
Here the HH8’s certified capacity at −15 °C exceeds its figure at −8.3 °C: these are the values ENERGY STAR publishes, shown as they are.
Only the YH5 LX is in our catalogue at 1.5 and 4 tons. Dimensions A × B × C as printed by YORK; A is the height (labelled for the HH8, inferred from the table for the YH5). Sources: YORK YH5 and HH8 technical guides (tables 3 and 4), read October 14, 2026; ENERGY STAR (dataset w7cv-9xjt) and
YORK designs the central system; AirGreen installs it in your home.
AirGreen measures the house, picks the family and the tonnage with you, then installs the outdoor unit and the air handler.
What YORK brings
- One indoor family: the JHEEach pair, outdoor unit plus JHE, has its own AHRI number.
R-454B refrigerantIn both families, with a refrigerant detection system (RDS) factory-installed in the JHE.- Electric backup heat by kit8HK electric heat kits for the JHE, for an all-electric system.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the ducts, the insulation and the electrical service.
- Clear quoteWith the AHRI number and the indicative LogisVert amount.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: the right family and tonnage, chosen at your home and installed by AirGreen.
All 8 YORK central systems, right below.
Filter by tonnage or series, then open the product page: each one gives the matched system, the AHRI number and the LogisVert amount.
Outside, the YORK unit. Inside, the JHE air handler.
A YORK central heat pump is two units certified together under one AHRI number: the one in the yard and the one in the house, in the basement or a closet. LogisVert excludes an indoor unit or ducts installed outside the insulated envelope, in the attic for example.
YH5 LX
- Top discharge, base from 24 × 24 in. (1.5 tons) to 35 1/4 × 31 3/4 in. (4 and 5 tons).
- 124 to 255 lb operating weight.
- Crankcase heater and discharge muffler factory-installed on every model.
HH8
- Side discharge: 13 to 17 5/7 in. deep, up to 57 1/2 in. tall (5 tons).
- 116.8 to 244.7 lb operating weight.
- Crankcase heater and base-pan heater as standard; the YH5 guide mentions no base-pan heater.
YORK JHE air handler
- Multiposition: upflow, downflow or horizontal; 21 in. deep at most.
- Nine-speed ECM blower, MaxAlloy™ “A” coil, factory-installed TXV.
- Total air leakage of 2% or less; 1 in. filter.
- At 4 and 5 tons, optional JSE short cabinet: upflow only, 57 in. tall at most. That is a different pairing: its AHRI number and LogisVert eligibility are checked on the quote.
Thermostat: YORK lists conventional controls for both families, and ENERGY STAR lists no connected function for either.
In deep cold, how much of its heating capacity each family keeps.
Four test points are published: 8.3 °C, −8.3 °C and −15 °C by ENERGY STAR; −25 °C by NEEP. Nothing is published between these points, and we don’t estimate any. The bar shows the share of the 8.3 °C capacity that remains.
4,363 heating degree-days a year (18 °C base).
The daily low drops below −10 °C on about 63 days a year.
The average January daily low is −14.0 °C: the −15 °C test point matches an ordinary January night.
The daily low drops below −20 °C on about 14 days a year, and below −30 °C on 0.27 days a year on average.
Below −25 °C, no value is published in the sources we read: we size the backup heat at the visit.
Sources: ENERGY STAR (dataset w7cv-9xjt), re-read October 26, 2026; NEEP, re-read October 27, 2026; Environment and Climate Change Canada (station 7025250), read October 14, 2026.
What the electrician and the refrigeration tech check first.
Values from the YORK YH5 and HH8 technical guides (tables 3 and 4), model by model. Dimensions A × B × C in inches, as printed: A is the height, from the bottom of the base pan to the top of the fan guard; B and C are the sides, screw heads included.
| Outdoor unit | Tonnage | Min. circuit ampacity (MCA) | Max. overcurrent protection | Liquid · vapour lines (in.) | Factory charge (15 ft) | Per foot | Weight | A × B × C (in.) | Fan |
|---|---|---|---|---|---|---|---|---|---|
| YH518E2S11+ JHE18B5AB2SS1 | 1.5 tons | 9.2 A | 15 A | 3/8 · 3/4 | 3 lb 12 oz | 0.57 oz/ft | 124 lb | 36 1/4 × 24 × 24 | 2,100 CFM |
| HH824E2S11+ JHE24B5AC2SS1 | 2 tons | 22 A | 25 A | 3/8 · 5/8 | 5 lb 1 oz | 0.54 oz/ft | 116.8 lb | 29 1/2 × 35 3/7 × 13 2/5 | 2,235 CFM |
| YH524E2S11+ JHE24B5AC2SS1 | 2 tons | 15.0 A | 25 A | 3/8 · 3/4 | 5 lb 4 oz | 0.57 oz/ft | 162 lb | 30 × 29 1/4 × 29 1/4 | 2,900 CFM |
| HH836E2S11+ JHE36B5CD2SS1 | 3 tons | 30 A | 35 A | 3/8 · 3/4 | 7 lb 7 oz | 0.57 oz/ft | 185.2 lb | 34 4/9 × 43 1/3 × 17 5/7 | 3,350 CFM |
| YH536E2S11+ JHE36B5CD2SS1 | 3 tons | 20.4 A | 30 A | 3/8 · 3/4 | 5 lb 1 oz | 0.57 oz/ft | 176 lb | 36 1/4 × 29 1/4 × 29 1/4 | 3,055 CFM |
| YH548E2S11+ JHE48C5CG2SS1 | 4 tons | 27.2 A | 45 A | 3/8 · 7/8 | 8 lb 6 oz | 0.60 oz/ft | 232 lb | 39 1/2 × 35 1/4 × 31 3/4 | 4,000 CFM |
| HH860E2S11+ JHE60C5CH2SS1 | 5 tons | 37 A | 45 A | 3/8 · 7/8 | 11 lb | 0.6 oz/ft | 244.7 lb | 57 1/2 × 38 2/5 × 13 | 4,820 CFM |
| YH560E2S11+ JHE60D5CH2SS1 | 5 tons | 33.7 A | 50 A | 3/8 · 1 1/8 (adapter, 7/8 valve) | 10 lb 5 oz | 0.67 oz/ft | 255 lb | 39 1/2 × 35 1/4 × 31 3/4 | 3,975 CFM |
- Power: 208/230 V, single phase, 60 Hz; normal range 187 to 252 V (AHRI 110, range A). Dual-element (time-delay) fuses or HACR breaker.
- Charge: the unit ships charged for the smallest matched indoor unit and 15 ft of lines. For another length, add or remove refrigerant by the difference between the actual (not equivalent) length and 15 ft, times the per-foot value.
- YH518 (1.5 tons): installation rules specific to the rotary compressor, detailed on the YH5 LX page.
- Not published in the YORK documents we read: maximum length and lift for the other models, clearances, operating range.
Both families use R-454B .
According to ENERGY STAR; YORK prints 467 in the YH5 guide.
Up to 78% lower GWP than
YORK factory-installs a refrigerant detection system (RDS) on the relevant equipment, including the JHE air handler. Local codes may require extra training or equipment.
Sources: YORK guides and “
The words on the spec sheet, in plain language. Tap or click a card.
Seasonal cooling efficiency under the current test method; the “2” sets it apart from the old SEER. The higher it is, the less cooling costs.
Seasonal heating efficiency, calculated for a climate region: region V stands for a colder climate than region IV. NEEP lists both for the HH8.
Heat delivered divided by electricity used, at a given temperature. A COP of 2 gives twice as much heat as electricity.
The YH5’s scroll compressor, from 2 tons up, runs at two capacities.
The HH8’s inverter-driven compressor adjusts its speed continuously; YORK states 35 to 100% of capacity.
The indoor section: blower, coil and, when needed, an electric heat kit.
The certificate of one exact pairing, outdoor and indoor unit.
The ENERGY STAR mention for heat pumps that meet cold-weather performance criteria.
LogisVert: 8 central systems on Hydro-Québec ’s list, from $545 to $4,440.
Amounts from
These amounts apply to the exact pairing on each product page. If you keep a furnace, use the JSE short cabinet or set the HH860 to 4 tons, the system is no longer that pairing: we check its eligibility, AHRI number and amount on the quote.
9-month deadline and program rules: YORK page, LogisVert section →
What people ask us about YORK central systems.
YH5 or HH8: which one for a Montreal house?
If deep-cold heating matters most, the HH8: its matched systems are ENERGY STAR
Do the YH5 and the HH8 use the same indoor unit?
At 2 and 3 tons, yes: the JHE24B5AC2SS1 and JHE36B5CD2SS1 serve both families. At 5 tons, our listings pair the YH560 with the JHE60D5CH2SS1 and the HH860 with the JHE60C5CH2SS1. Each matched system has its own AHRI number.
Can I keep my gas furnace?
YORK allows pairing the YH5 and the HH8 with a gas furnace, and for the HH8, even one of another brand. The indoor unit is then no longer the JHE on our list: LogisVert eligibility, the AHRI number and the amount of that combination are checked on the quote. Gas work goes to a partner holding the proper RBQ licence.
Why does the HH8 get more LogisVert than the YH5?
Your YORK central system, chosen at your home and installed by AirGreen.
At the free visit, we pick the family, YH5 LX or HH8, and the tonnage with you; the quote gives the exact matched system and its AHRI number.
Sources and dates checked
- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, 8 YORK records (IDs 3713095, 3627807, 4498100, 3627809, 3627810, 3437360, 3715161, 3715141), Canadian market, read October 14, 2026, re-read October 26, 2026; “Most Efficient” designation re-checked October 27, 2026.
- NEEP, Cold Climate Air Source Heat Pump List, AHRI certificates 214396076, 215853295 and 215853276, read October 14, 2026, re-read October 27, 2026 (no YH5 listed).
Hydro-Québec , LogisVert eligible heat pump search tool, file of October 26, 2026, “homeowner, existing house” profile.Hydro-Québec , LogisVert participation guide for residential customers, version 1.10 of September 15, 2026 (9-month deadline, p. 5; ineligible work, p. 14; rates, p. 15), read October 14, 2026.- YORK, YH5 and HH8 technical guides, tables 3 and 4 (copies in our documents).
- YORK, “Air handlers” and “
R-454B ” pages of the technical guides (copies in our documents). - YORK, HH8, YH5 and JHE product pages, and HH8 (PUBL-3444-C-0124) and JHE/JME (PUBL-3457-B-0324) sell sheets, read October 14, 2026.
- Environment and Climate Change Canada,
1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026. - airgreen.ca product pages: the matched systems we carry and the links to them.
LogisVert amounts are indicative, from