HITACHI airHome Multi · 4 zones · updated October 28, 2026

HITACHI 4-zone heat pump: 28 published quadruples for the RAM-G36N4HAA, none for the RAM-G42N5HAA

Two outdoor units take four heads: the RAM-G36N4HAA and the RAM-G42N5HAA. For the first, Hitachi publishes 28 quadruples, up to 48,000 BTU/h, 13 of them with an 18,000, 22,000 or 24,000 head. For the second, no table. Neither is ENERGY STAR Cold Climate, so LogisVert pays $50 per 1,000 BTU/h: $1,250 or $1,500. And we have not published any 4-zone installation yet.

HITACHI4 zones

Two units, no cold climate

Indicative LogisVert, four non-ducted heads. Tap a row to open the system.

28quadruples published by Hitachi, RAM-G36N4HAA
$1,250RAM-G36N4HAA, all non-ducted
$1,500RAM-G42N5HAA, all non-ducted
04-zone installations published as of Oct. 28, 2026
The HITACHI shop · airHome Multi · 4 zones

The 2 four-zone systems, right below.

Each with four wall heads. A head of another type sometimes changes the certificate: we check it on quotation.

AirGreenHITACHI
01 · Planner

Four rooms, two possible units.

Set your four heads or start from an example home. The planner looks for your combination among the RAM-G36N4HAA’s 28 quadruples, and reminds you that the RAM-G42N5HAA is always confirmed with the distributor.

Example homes
Living roomWall · 12,000 BTU/h
Bedroom 1Wall · 9,000 BTU/h
Bedroom 2Wall · 9,000 BTU/h
Bedroom 3Wall · 9,000 BTU/h
ConfigurationAll non-ducted
Total connected39,000 BTU/h

1 outdoor unit out of 4 takes these rooms according to Hitachi’s tables. The RAM-G42N5HAA is confirmed with the distributor.

Not allowedRAM-G18N2HAA18,000 BTU/h · 2 connections · heads 7,000 to 12,000

Only 2 connections: 4 rooms do not fit.

AHRI216097706
ENERGY STAR (US market)
$745Indicative LogisVert

MCA / MOP · 50 m of line set in total

Not allowedRAM-G24N3HAA24,000 BTU/h · 3 connections · heads 7,000 to 18,000

Only 3 connections: 4 rooms do not fit.

AHRI216097707
ENERGY STAR Cold Climate (US market)Most Efficient
$1,920Indicative LogisVert

MCA / MOP · 60 m of line set in total

Published by HitachiRAM-G36N4HAA36,000 BTU/h · 4 connections · heads 7,000 to 24,000

12,000 + 9,000 + 9,000 + 9,000 = 39,000 BTU/h: a combination listed in Hitachi’s table 3.7.

AHRI216097708
ENERGY STAR (US market)
$1,250Indicative LogisVert

MCA / MOP 24 / 40 A · 70 m of line set in total

See this system in our shop
To be confirmedRAM-G42N5HAA42,000 BTU/h · 5 connections · no published table

Hitachi publishes no combination table for this unit: we confirm each combination with the distributor.

AHRI215827114
ENERGY STAR (US market)
$1,500Indicative LogisVert, if the combination is confirmed

MCA / MOP 30 / 50 A · 80 m of line set in total

See this system in our shop

Combinations published by Hitachi (airHome Multi technical guide): RAM-G36N4HAA (table 3.7), 21 pairs, 32 triples and 28 quadruples, some with an 18,000, 22,000 or 24,000 head, 48,000 BTU/h at most. A combination missing from its unit’s list is not allowed. RAM-G42N5HAA: Hitachi publishes no combination table; we confirm each combination with the distributor. Mini-cassettes and floor consoles count as non-ducted in the certificates; a RAD-GJ ducted head changes the AHRI number. In its tables, Hitachi lists the largest mini-cassette as size “22” (RAI-GJ22QHAA): it is the RAI-GJ24QHAA we sell as 24,000 BTU/h (technical guide: 24,000 BTU/h cooling, 20,500 BTU/h heating). The planner counts it as 22,000 on the RAM-G36N4HAA. Example sizes: each room’s size is worked out during the visit. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.

02 · The quadruples

Fifteen quadruples of small heads, thirteen with one large head.

Table 3.7 of Hitachi’s guide lists 28 combinations of four heads for the RAM-G36N4HAA. Fifteen use only 7,000 to 12,000 heads; thirteen have one 18,000, 22,000 or 24,000 head, never two. The RAM-G42N5HAA has no table: every combination is confirmed with the distributor.

12,000 heads and smaller 15
  • 7 + 7 + 7 + 728,000 BTU/h
  • 7 + 7 + 7 + 930,000 BTU/h
  • 7 + 7 + 9 + 932,000 BTU/h
  • 7 + 7 + 7 + 1233,000 BTU/h
  • 7 + 9 + 9 + 934,000 BTU/h
  • 7 + 7 + 9 + 1235,000 BTU/h
  • 9 + 9 + 9 + 936,000 BTU/h
  • 7 + 9 + 9 + 1237,000 BTU/h
  • 7 + 7 + 12 + 1238,000 BTU/h
  • 9 + 9 + 9 + 1239,000 BTU/h
  • 7 + 9 + 12 + 1240,000 BTU/h
  • 9 + 9 + 12 + 1242,000 BTU/h
  • 7 + 12 + 12 + 1243,000 BTU/h
  • 9 + 12 + 12 + 1245,000 BTU/h
  • 12 + 12 + 12 + 1248,000 BTU/h
With an 18,000 head 7
  • 7 + 7 + 7 + 1839,000 BTU/h
  • 7 + 7 + 9 + 1841,000 BTU/h
  • 7 + 9 + 9 + 1843,000 BTU/h
  • 7 + 7 + 12 + 1844,000 BTU/h
  • 9 + 9 + 9 + 1845,000 BTU/h
  • 7 + 9 + 12 + 1846,000 BTU/h
  • 9 + 9 + 12 + 1848,000 BTU/h
“24,000” cassette (22) 4
  • 7 + 7 + 7 + 2243,000 BTU/h
  • 7 + 7 + 9 + 2245,000 BTU/h
  • 7 + 9 + 9 + 2247,000 BTU/h
  • 7 + 7 + 12 + 2248,000 BTU/h
With a 24,000 head 2
  • 7 + 7 + 7 + 2445,000 BTU/h
  • 7 + 7 + 9 + 2447,000 BTU/h

Sizes in thousands of BTU/h, as Hitachi writes them (table 3.7 of the technical guide, re-read in full Oct. 28, 2026). Size 22 is the RAI-GJ22QHAA mini-cassette, which we sell as the 24,000 BTU/h RAI-GJ24QHAA. The bar shows the total against the 48,000 BTU/h maximum connected capacity. Do the arithmetic: these are every combination of four table sizes that fits within 48,000 BTU/h, and no other. None has two heads above 12,000.

Heads (BTU/h)TotalRAM-G36N4HAARAM-G42N5HAA
12,000 + 12,000 + 12,000 + 12,00048,000 BTU/hpublishedto confirmno table
7,000 + 7,000 + 12,000 + 22,00048,000 BTU/hpublishedto confirmno table
9,000 + 9,000 + 12,000 + 18,00048,000 BTU/hpublishedto confirmno table
7,000 + 7,000 + 9,000 + 24,00047,000 BTU/hpublishedto confirmno table
7,000 + 9,000 + 9,000 + 22,00047,000 BTU/hpublishedto confirmno table
7,000 + 7,000 + 12,000 + 24,00050,000 BTU/hnot allowedtotal too highto confirmno table
7,000 + 12,000 + 12,000 + 18,00049,000 BTU/hnot allowedtotal too highto confirmno table
9,000 + 9,000 + 9,000 + 22,00049,000 BTU/hnot allowedtotal too highto confirmno table
7,000 + 7,000 + 18,000 + 18,00050,000 BTU/hnot allowedtotal too highto confirmno table
12,000 + 12,000 + 12,000 + 18,00054,000 BTU/hnot allowedtotal too highto confirmno table

At the edge of the limit: the first five lines total 47,000 or 48,000 BTU/h and are in table 3.7; the next five go over 48,000 and are not. The RAM-G42N5HAA has no table.

03 · A ducted head

One more ducted head, and the amount drops.

A ducted head in the system changes the AHRI number, and the amount follows. Slide the number of ducted heads: on the RAM-G36N4HAA, the grant goes from $1,250 to $1,200, then $1,150 if all four are ducted. On the RAM-G42N5HAA, it drops to $0 with the first one.

0/ 4All non-ducted
01234
RAM-G36N4HAAAHRI 216097708
ENERGY STAR (US market)
$1,250Indicative LogisVert
RAM-G42N5HAAAHRI 215827114
ENERGY STAR (US market)
$1,500Indicative LogisVert

NEEP and ENERGY STAR certificates re-checked Oct. 28, 2026; indicative LogisVert, list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates. A mini-cassette or a floor console counts as non-ducted.

04 · The two units

RAM-G36N4HAA or RAM-G42N5HAA: a table against one more connection.

The RAM-G36N4HAA has a published table, a published fuse and a smaller cabinet. The RAM-G42N5HAA keeps one free connection, reaches further in line length and delivers more heat at -20°C, but Hitachi publishes no combination rule for it.

RAM-G36N4HAARAM-G42N5HAA
Connections, free after 4 heads4 · 05 · 1
Hitachi table with 4 heads28 quadruples, 48,000 BTU/h at mostnot published
Gas ports (in.)3/8 × 3 + 1/2 × 13/8 × 3 + 1/2 × 2
Certified at -8.3°C25,000 BTU/h30,000 BTU/h
29,000 per the brochure
Maximum at -20°C18,300 BTU/h · COP 1.6524,500 BTU/h · COP 1.8
Maximum at 8.3°C42,000 BTU/h51,000 BTU/h
SEER2 / EER223 / 12.023 / 12.5
HSPF2 Region IV / V (NEEP)9.3 / —
brochure: 7.64 in Region V
9.2 / 7.29
brochure: 7.2 in Region V
MCA / MOP24 / 40 A30 / 50 A (3 to 5 heads)
Recommended fuse (guide)25 Anot published
Total line set, total height70 m · 20 m80 m · 23 m
Cabinet850 × 800 × 298 mm · 74 kg950 × 945 × 370 mm · 98 kg
Drain, outdoor sound16 mm · 56 dB(A)26 mm · 58 dB(A)
LogisVert, 4 non-ducted heads$1,250$1,500

airHome Multi brochures (EN and FR), technical guide (which does not cover the RAM-G42N5HAA) and NEEP certificates 216097708 and 215827114. Region V: NEEP gives no value for the RAM-G36N4HAA; for the RAM-G42N5HAA, NEEP certifies 7.29 and the brochure prints 7.2.

05 · No cold climate

Four rooms, and no cold-climate unit left.

The whole range heats down to -20°C according to Hitachi. With four rooms, the certification changes, and the LogisVert rate with it.

The $50 rateTwo ENERGY STAR units, neither cold climate

Both are on the ENERGY STAR list (US market), without the cold-climate designation. LogisVert therefore pays $50 per 1,000 BTU/h certified at -8.3°C: 25 × $50 = $1,250 and 30 × $50 = $1,500.

One room fewer3 zones: the RAM-G24N3HAA returns

Cold climate and Most Efficient, it earns $1,920, but it only has three connections and refuses 24,000 heads. The 3-zone page

One more room5 zones: only the RAM-G42N5HAA is left

The RAM-G36N4HAA drops out with its four connections. The RAM-G42N5HAA stands alone, with no published table, on the 30 / 50 A tier. The 5-zone page

No 4-zone installation published

As of Oct. 28, 2026, our 33 published airHome Multi systems break down as: 16 in 2 zones, 16 in 3 zones and 1 with no zone count given. No 4-zone article to show you yet: our published installations are on the 2-zone and 3-zone pages.

06 · Frequently asked questions

Your 4-zone questions, answered.

The RAM-G36N4HAA has a published table (28 quadruples), 70 m of line set, 24 / 40 A and $1,250 of LogisVert. The RAM-G42N5HAA has no table, reaches 80 m, needs 30 / 50 A, earns $1,500 and keeps one free connection. The choice is made room by room, during the visit.

07 · The HITACHI space

One room fewer, one more, or the whole range.

Sources, with the date we read them

  1. Hitachi (Johnson Controls Hitachi Air Conditioning), airHome Multi brochure “Multi-Split Inverter Heat Pump System”, EN “February 2025_CA”, read Oct. 14, 2026.
  2. Hitachi, airHome Multi brochure (FR), “December 2024_CA”, read Oct. 14, 2026.
  3. Hitachi, technical guide “TC_ NA airHome Multi-2024 (EN) - 00”, 183 pages: defrost factors 3.4, adaptors 13.1, read Oct. 14, 2026; combination tables 3.5 to 3.7 and model lists by size (PDF p. 58 to 67), re-read in full Oct. 28, 2026.
  4. NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org), records by AHRI number, read Oct. 14, 2026 and re-checked Oct. 28, 2026.
  5. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), read Oct. 14, 2026 and re-checked Oct. 28, 2026. For airHome units, the “markets” field lists the United States.
  6. Hydro-Québec, LogisVert eligible heat pump search tool (homeowner list), read Oct. 14, 2026; amounts recomputed Oct. 28, 2026 from the ENERGY STAR and NEEP certificates, at the rate of LogisVert guide v1.10.
  7. Hydro-Québec, residential LogisVert participant’s guide, version 1.10, September 15, 2026.
  8. Hitachi Cooling & Heating Canada, “Warranties & Training” page (mini-split systems), read Oct. 14, 2026.
  9. AirGreen, “Nos réalisations” blog, Hitachi articles published as of Oct. 28, 2026.

LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.