Only 2 connections: 3 rooms do not fit.
MCA / MOP · 50 m of line set in total
See this system in our shopThree outdoor units take three heads. The RAM-G24N3HAA, the smallest of the three, is the only ENERGY STAR Cold Climate one: $1,920 in LogisVert, against $1,250 for the RAM-G36N4HAA and $1,500 for the RAM-G42N5HAA. In return, it uses all three of its connections and accepts no 24,000 head.
Indicative LogisVert, three non-ducted heads. Tap a row to open the system.
Each with three wall heads. A ceiling mini-cassette or a ducted head in the basement is validated on quotation, against Hitachi’s table.
Start from an example home or set each head. The planner tells you whether the RAM-G24N3HAA, the one that earns the most, accepts your three heads, and if not, which of the two other units takes them and why.
2 outdoor units out of 4 take these rooms according to Hitachi’s tables. The RAM-G42N5HAA is confirmed with the distributor.
Only 2 connections: 3 rooms do not fit.
MCA / MOP · 50 m of line set in total
See this system in our shop12,000 + 9,000 + 9,000 = 30,000 BTU/h: a combination listed in Hitachi’s table 3.6.
MCA / MOP 19 / 35 A · 60 m of line set in total
See this system in our shop12,000 + 9,000 + 9,000 = 30,000 BTU/h: a combination listed in Hitachi’s table 3.7.
MCA / MOP 24 / 40 A · 70 m of line set in total
See this system in our shopHitachi publishes no combination table for this unit: we confirm each combination with the distributor.
MCA / MOP 30 / 50 A · 80 m of line set in total
See this system in our shopCombinations published by Hitachi (airHome Multi technical guide): RAM-G24N3HAA (table 3.6), 10 pairs and 13 triples of 7,000 to 18,000 BTU/h heads, no 22,000 or 24,000, 36,000 BTU/h at most; RAM-G36N4HAA (table 3.7), 21 pairs, 32 triples and 28 quadruples, some with an 18,000, 22,000 or 24,000 head, 48,000 BTU/h at most. A combination missing from its unit’s list is not allowed. RAM-G42N5HAA: Hitachi publishes no combination table; we confirm each combination with the distributor. Mini-cassettes and floor consoles count as non-ducted in the certificates; a RAD-GJ ducted head changes the AHRI number. In its tables, Hitachi lists the largest mini-cassette as size “22” (RAI-GJ22QHAA): it is the RAI-GJ24QHAA we sell as 24,000 BTU/h (technical guide: 24,000 BTU/h cooling, 20,500 BTU/h heating). The planner counts it as 22,000 on the RAM-G36N4HAA. Example sizes: each room’s size is worked out during the visit. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.
The RAM-G24N3HAA is certified at 16,000 BTU/h at -8.3°C, against 25,000 for the RAM-G36N4HAA and 30,000 for the RAM-G42N5HAA. But it is the only ENERGY STAR Cold Climate unit: Hydro-Québec pays it $120 per 1,000 BTU/h, against $50 for the other two. Tap a configuration: its amount does not move, while the other two drop.
Indicative amounts: list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates. Hydro-Québec pays on the heat certified at -8.3°C: $120 per 1,000 BTU/h for an ENERGY STAR Cold Climate unit, $50 otherwise.
Since June 15, 2026, Hydro-Québec’s multi-unit bonus adds $100 per 1,000 BTU/h at -8.3°C, bringing the rate to $220 per 1,000 BTU/h, in some qualifying rental buildings. It targets ENERGY STAR Cold Climate wall-mounted heat pumps: in Hydro-Québec’s list read Oct. 14, 2026, only the RAM-G24N3HAA certificates are flagged as eligible. The conditions are on our LogisVert page.
Three heads from 7,000 to 12,000: both units with a table accept them. With an 18,000 head, the RAM-G24N3HAA stops at 36,000 BTU/h in total: its table keeps 7,000 + 7,000 + 18,000, 7,000 + 9,000 + 18,000 and 9,000 + 9,000 + 18,000. A 24,000 head, or our 24,000 mini-cassette (size 22 for Hitachi), only fits the RAM-G36N4HAA.
| Heads (BTU/h) | Total | RAM-G24N3HAA | RAM-G36N4HAA | RAM-G42N5HAA |
|---|---|---|---|---|
| 7,000 + 7,000 + 7,000 | 21,000 BTU/h | published | published | to confirmno table |
| 9,000 + 9,000 + 9,000 | 27,000 BTU/h | published | published | to confirmno table |
| 9,000 + 9,000 + 12,000 | 30,000 BTU/h | published | published | to confirmno table |
| 12,000 + 12,000 + 12,000 | 36,000 BTU/h | published | published | to confirmno table |
| 7,000 + 7,000 + 18,000 | 32,000 BTU/h | published | published | to confirmno table |
| 7,000 + 9,000 + 18,000 | 34,000 BTU/h | published | published | to confirmno table |
| 9,000 + 9,000 + 18,000 | 36,000 BTU/h | published | published | to confirmno table |
| 7,000 + 12,000 + 18,000 | 37,000 BTU/h | not allowedtotal too high | published | to confirmno table |
| 12,000 + 12,000 + 18,000 | 42,000 BTU/h | not allowedtotal too high | published | to confirmno table |
| 12,000 + 18,000 + 18,000 | 48,000 BTU/h | not allowedtotal too high | published | to confirmno table |
| 9,000 + 9,000 + 22,000 | 40,000 BTU/h | not allowedsize not in table | published | to confirmno table |
| 7,000 + 18,000 + 22,000 | 47,000 BTU/h | not allowedsize not in table | published | to confirmno table |
| 12,000 + 12,000 + 24,000 | 48,000 BTU/h | not allowedsize not in table | published | to confirmno table |
| 18,000 + 18,000 + 18,000 | 54,000 BTU/h | not allowedtotal too high | not allowedtotal too high | to confirmno table |
Statuses from tables 3.6 and 3.7 of Hitachi’s technical guide, re-read in full Oct. 28, 2026: 13 triples for the RAM-G24N3HAA, 36,000 BTU/h at most; 32 for the RAM-G36N4HAA, 48,000 BTU/h at most. Size 22 is the RAI-GJ22QHAA mini-cassette, which we sell as the 24,000 BTU/h RAI-GJ24QHAA. The planner applies the same lists.
On the RAM-G24N3HAA, all three gas ports are 3/8 in. An 18,000 wall, floor or ducted head, whose gas line is 1/2 in., connects with the TA261D-4-001 adaptor and SEAL-3/8 seal, which Hitachi supplies with the unit. An 18,000 mini-cassette, at 3/8 in., needs none. And with three heads, all three of its connections are taken.
It is the adaptor for a 1/2 in. line on a 3/8 in. port, supplied with the outdoor unit according to the technical guide, tightened to 30-40 N·m (22-30 ft-lbf). Hitachi asks that the seal always be fitted with the adaptor.
| RAM-G24N3HAA | RAM-G36N4HAA | RAM-G42N5HAA | |
|---|---|---|---|
| Wall, floor or ducted 18,000 head (1/2 in. gas) | 3/8 port: TA261D-4-001 + SEAL-3/8 | 3/8 port: TA261D-4-001 + SEAL-3/8 1/2 port: no adaptor | no table: to be confirmed |
| 18,000 mini-cassette (3/8 in. gas) | 3/8 port: no adaptor | 3/8 port: no adaptor 1/2 port: TA261D-6-002 + SEAL-1/2 | no table: to be confirmed |
| 24,000 wall head (5/8 in. gas) | not allowed by the table | 3/8 port: ADAPTOR3-5 + SEAL-3/8 1/2 port: TA261D-7-003 + SEAL-1/2 | no table: to be confirmed |
| 24,000 ducted head (1/2 in. gas) | not allowed by the table | 3/8 port: TA261D-4-001 + SEAL-3/8 1/2 port: no adaptor | no table: to be confirmed |
| Total line set | 60 m | 70 m | 80 m |
| Total height | 20 m | 20 m | 23 m |
| Chargeless / extra charge per metre | 30 m / 12 g/m | 30 m / 12 g/m | not published |
| MCA / MOP | 19 / 35 A | 24 / 40 A | 30 / 50 A (3 to 5 heads) |
| Cabinet | 850 × 800 × 298 mm 52 kg (Hitachi’s sheet also says 121 lb) | 850 × 800 × 298 mm 74 kg | 950 × 945 × 370 mm 98 kg |
Every 7,000 to 12,000 head, and the 18,000 mini-cassette, has a 3/8 in. gas line: no adaptor on a 3/8 in. port. “24,000” mini-cassette: the guide gives 1/2 in., the brochure 3/8 in.; we check the connection during the visit. Adaptors supplied with the outdoor unit (technical guide, section 13.1, which does not cover the RAM-G42N5HAA); Hitachi does not publish the rule for which head goes on which port. Lines, electrical and cabinets: airHome Multi brochures.
Three rooms is the last count where a cold-climate unit is still possible. One room fewer or more, and the numbers change.
Four possible units instead of three, including the $745 RAM-G18N2HAA and its 7,000 to 12,000 heads. The LogisVert spread widens, $745 to $1,920, and the RAM-G42N5HAA drops to the 25 / 40 A tier. The 2-zone page
Only the RAM-G36N4HAA and the RAM-G42N5HAA remain, neither cold climate: the top amount drops to $1,500. The RAM-G36N4HAA table lists 28 quadruples; the RAM-G42N5HAA has no table. The 4-zone page
The three units on this page heat down to -20°C according to Hitachi, like the whole airHome Multi range. The number of rooms changes which units are possible, not the cold they handle. Winter, on the airHome Multi page
Homes in the West Island, east-end Montréal and Laval, all published on our blog.
Published on our “Nos réalisations” blog as of Oct. 28, 2026. Here are the places, then four of those articles.
Because it is the only ENERGY STAR Cold Climate unit. Hydro-Québec pays $120 per 1,000 BTU/h certified at -8.3°C: 16 × $120 = $1,920. The RAM-G36N4HAA, certified at 25,000 BTU/h but without the cold-climate designation, gets $50: 25 × $50 = $1,250.
No. The RAM-G24N3HAA table stops at 18,000 heads. For a 24,000 head in 3 zones, it is the RAM-G36N4HAA, up to 12,000 + 12,000 + 24,000 in its table.
Yes, with two small heads: Hitachi’s table 3.6 publishes 7,000 + 7,000 + 18,000, 7,000 + 9,000 + 18,000 and 9,000 + 9,000 + 18,000. With a 12,000 head alongside, the total goes over 36,000 BTU/h and the combination is not allowed. An 18,000 wall, floor or ducted head (1/2 in. line) connects to the 3/8 in. port with the TA261D-4-001 adaptor and its seal, supplied by Hitachi; an 18,000 mini-cassette, at 3/8 in., connects without one.
No: it has three connections, all taken with three heads. The RAM-G36N4HAA keeps one free, the RAM-G42N5HAA two.
For a 24,000 head, or our “24,000” mini-cassette; for a total above 36,000 BTU/h, such as 7,000 + 12,000 + 18,000; or to keep a free connection. In return, the LogisVert amount drops from $1,920 to $1,250.
An extra $100 per 1,000 BTU/h at -8.3°C, bringing the rate to $220 per 1,000 BTU/h, in some qualifying rental buildings, on installations done since June 15, 2026. In Hydro-Québec’s list read Oct. 14, 2026, only the RAM-G24N3HAA certificates are flagged as eligible. The conditions are on our LogisVert page.
16 are published on our blog as of Oct. 28, 2026, from Senneville to Saint-Vincent-de-Paul. The list of places is higher up on this page.
Hitachi and AirGreen warranties: explained once for the whole brand, on the HITACHI page.
No question matches. Call us at 514 316-2973.
During the visit, we measure each room and check whether your three heads fit the RAM-G24N3HAA table. If they do, that is the largest LogisVert amount on the page. If not, we compare the two other units, with the numbers, in the quotation.
Hydro-Québec never solicits anyone by phone or door to door for LogisVert. If someone calls “on behalf of Hydro-Québec” to sell you a heat pump, hang up.
Monday to Thursday 8 a.m. to 6 p.m. · Friday 8 a.m. to 4 p.m.








LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.