AirGreenHITACHI
HITACHI COOLING & HEATING · airHome Multi · 3 zonesThe HITACHI space at AirGreenThree rooms on a single airHome Multi outdoor unit, sold and installed by AirGreen.
All of HITACHI
Free in-home estimate3 systems · 3 heads
HITACHI airHome Multi · 3 zones · updated October 28, 2026

HITACHI 3-zone heat pump: the smallest outdoor unit earns the most, $1,920

Three outdoor units take three heads. The RAM-G24N3HAA, the smallest of the three, is the only ENERGY STAR Cold Climate one: $1,920 in LogisVert, against $1,250 for the RAM-G36N4HAA and $1,500 for the RAM-G42N5HAA. In return, it uses all three of its connections and accepts no 24,000 head.

HITACHI3 zones

Three units, three amounts

Indicative LogisVert, three non-ducted heads. Tap a row to open the system.

$1,920RAM-G24N3HAA, the smallest
$1,250RAM-G36N4HAA, 36,000 BTU/h
3possible outdoor units
16three-zone installations published as of Oct. 28, 2026
The HITACHI shop · airHome Multi · 3 zones

The 3 three-zone systems, right below.

Each with three wall heads. A ceiling mini-cassette or a ducted head in the basement is validated on quotation, against Hitachi’s table.

AirGreenHITACHI
01 · Planner

Three rooms, three possible units.

Start from an example home or set each head. The planner tells you whether the RAM-G24N3HAA, the one that earns the most, accepts your three heads, and if not, which of the two other units takes them and why.

Example homes
Living roomWall · 12,000 BTU/h
Bedroom 1Wall · 9,000 BTU/h
Bedroom 2Wall · 9,000 BTU/h
ConfigurationAll non-ducted
Total connected30,000 BTU/h

2 outdoor units out of 4 take these rooms according to Hitachi’s tables. The RAM-G42N5HAA is confirmed with the distributor.

Not allowedRAM-G18N2HAA18,000 BTU/h · 2 connections · heads 7,000 to 12,000

Only 2 connections: 3 rooms do not fit.

AHRI216097706
ENERGY STAR (US market)
$745Indicative LogisVert

MCA / MOP · 50 m of line set in total

Published by HitachiRAM-G24N3HAA24,000 BTU/h · 3 connections · heads 7,000 to 18,000

12,000 + 9,000 + 9,000 = 30,000 BTU/h: a combination listed in Hitachi’s table 3.6.

AHRI216097707
ENERGY STAR Cold Climate (US market)Most Efficient
$1,920Indicative LogisVert

MCA / MOP 19 / 35 A · 60 m of line set in total

See this system in our shop
Published by HitachiRAM-G36N4HAA36,000 BTU/h · 4 connections · heads 7,000 to 24,000

12,000 + 9,000 + 9,000 = 30,000 BTU/h: a combination listed in Hitachi’s table 3.7.

AHRI216097708
ENERGY STAR (US market)
$1,250Indicative LogisVert

MCA / MOP 24 / 40 A · 70 m of line set in total

See this system in our shop
To be confirmedRAM-G42N5HAA42,000 BTU/h · 5 connections · no published table

Hitachi publishes no combination table for this unit: we confirm each combination with the distributor.

AHRI215827114
ENERGY STAR (US market)
$1,500Indicative LogisVert, if the combination is confirmed

MCA / MOP 30 / 50 A · 80 m of line set in total

See this system in our shop

Combinations published by Hitachi (airHome Multi technical guide): RAM-G24N3HAA (table 3.6), 10 pairs and 13 triples of 7,000 to 18,000 BTU/h heads, no 22,000 or 24,000, 36,000 BTU/h at most; RAM-G36N4HAA (table 3.7), 21 pairs, 32 triples and 28 quadruples, some with an 18,000, 22,000 or 24,000 head, 48,000 BTU/h at most. A combination missing from its unit’s list is not allowed. RAM-G42N5HAA: Hitachi publishes no combination table; we confirm each combination with the distributor. Mini-cassettes and floor consoles count as non-ducted in the certificates; a RAD-GJ ducted head changes the AHRI number. In its tables, Hitachi lists the largest mini-cassette as size “22” (RAI-GJ22QHAA): it is the RAI-GJ24QHAA we sell as 24,000 BTU/h (technical guide: 24,000 BTU/h cooling, 20,500 BTU/h heating). The planner counts it as 22,000 on the RAM-G36N4HAA. Example sizes: each room’s size is worked out during the visit. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.

02 · LogisVert

$120 against $50 per 1,000 BTU/h: the certification makes the difference.

The RAM-G24N3HAA is certified at 16,000 BTU/h at -8.3°C, against 25,000 for the RAM-G36N4HAA and 30,000 for the RAM-G42N5HAA. But it is the only ENERGY STAR Cold Climate unit: Hydro-Québec pays it $120 per 1,000 BTU/h, against $50 for the other two. Tap a configuration: its amount does not move, while the other two drop.

RAM-G24N3HAA
AHRI 216097707
$1,920 16 × $120 = $1,920
RAM-G36N4HAA
AHRI 216097708
$1,250 25 × $50 = $1,250
RAM-G42N5HAA
AHRI 215827114
$1,500 30 × $50 = $1,500
RAM-G24N3HAA
ENERGY STAR Cold Climate (US market)Most Efficient
RAM-G36N4HAA
ENERGY STAR (US market)
RAM-G42N5HAA
ENERGY STAR (US market)

Indicative amounts: list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates. Hydro-Québec pays on the heat certified at -8.3°C: $120 per 1,000 BTU/h for an ENERGY STAR Cold Climate unit, $50 otherwise.

And in a qualifying rental building

Since June 15, 2026, Hydro-Québec’s multi-unit bonus adds $100 per 1,000 BTU/h at -8.3°C, bringing the rate to $220 per 1,000 BTU/h, in some qualifying rental buildings. It targets ENERGY STAR Cold Climate wall-mounted heat pumps: in Hydro-Québec’s list read Oct. 14, 2026, only the RAM-G24N3HAA certificates are flagged as eligible. The conditions are on our LogisVert page.

03 · The triples

With an 18,000 head, the RAM-G24N3HAA keeps three triples.

Three heads from 7,000 to 12,000: both units with a table accept them. With an 18,000 head, the RAM-G24N3HAA stops at 36,000 BTU/h in total: its table keeps 7,000 + 7,000 + 18,000, 7,000 + 9,000 + 18,000 and 9,000 + 9,000 + 18,000. A 24,000 head, or our 24,000 mini-cassette (size 22 for Hitachi), only fits the RAM-G36N4HAA.

The connected-capacity window, per the spec rows
RAM-G24N3HAA2 to 3 heads · 14,000 to 36,000 BTU/h
RAM-G36N4HAA2 to 4 heads · 14,000 to 48,000 BTU/h
RAM-G42N5HAAwindow not published
Heads (BTU/h)TotalRAM-G24N3HAARAM-G36N4HAARAM-G42N5HAA
7,000 + 7,000 + 7,00021,000 BTU/hpublishedpublishedto confirmno table
9,000 + 9,000 + 9,00027,000 BTU/hpublishedpublishedto confirmno table
9,000 + 9,000 + 12,00030,000 BTU/hpublishedpublishedto confirmno table
12,000 + 12,000 + 12,00036,000 BTU/hpublishedpublishedto confirmno table
7,000 + 7,000 + 18,00032,000 BTU/hpublishedpublishedto confirmno table
7,000 + 9,000 + 18,00034,000 BTU/hpublishedpublishedto confirmno table
9,000 + 9,000 + 18,00036,000 BTU/hpublishedpublishedto confirmno table
7,000 + 12,000 + 18,00037,000 BTU/hnot allowedtotal too highpublishedto confirmno table
12,000 + 12,000 + 18,00042,000 BTU/hnot allowedtotal too highpublishedto confirmno table
12,000 + 18,000 + 18,00048,000 BTU/hnot allowedtotal too highpublishedto confirmno table
9,000 + 9,000 + 22,00040,000 BTU/hnot allowedsize not in tablepublishedto confirmno table
7,000 + 18,000 + 22,00047,000 BTU/hnot allowedsize not in tablepublishedto confirmno table
12,000 + 12,000 + 24,00048,000 BTU/hnot allowedsize not in tablepublishedto confirmno table
18,000 + 18,000 + 18,00054,000 BTU/hnot allowedtotal too highnot allowedtotal too highto confirmno table

Statuses from tables 3.6 and 3.7 of Hitachi’s technical guide, re-read in full Oct. 28, 2026: 13 triples for the RAM-G24N3HAA, 36,000 BTU/h at most; 32 for the RAM-G36N4HAA, 48,000 BTU/h at most. Size 22 is the RAI-GJ22QHAA mini-cassette, which we sell as the 24,000 BTU/h RAI-GJ24QHAA. The planner applies the same lists.

04 · Ports and lines

Three 3/8 in. ports, and an 18,000 wall head that needs an adaptor.

On the RAM-G24N3HAA, all three gas ports are 3/8 in. An 18,000 wall, floor or ducted head, whose gas line is 1/2 in., connects with the TA261D-4-001 adaptor and SEAL-3/8 seal, which Hitachi supplies with the unit. An 18,000 mini-cassette, at 3/8 in., needs none. And with three heads, all three of its connections are taken.

Connections used with three heads
RAM-G24N3HAA3 of 3 usedgas 3/8 × 3 in.
RAM-G36N4HAA3 of 4 usedgas 3/8 × 3 + 1/2 × 1 in.
RAM-G42N5HAA3 of 5 usedgas 3/8 × 3 + 1/2 × 2 in.
TA261D-4-001 + SEAL-3/8

It is the adaptor for a 1/2 in. line on a 3/8 in. port, supplied with the outdoor unit according to the technical guide, tightened to 30-40 N·m (22-30 ft-lbf). Hitachi asks that the seal always be fitted with the adaptor.

RAM-G24N3HAARAM-G36N4HAARAM-G42N5HAA
Wall, floor or ducted 18,000 head (1/2 in. gas)3/8 port: TA261D-4-001 + SEAL-3/83/8 port: TA261D-4-001 + SEAL-3/8
1/2 port: no adaptor
no table: to be confirmed
18,000 mini-cassette (3/8 in. gas)3/8 port: no adaptor3/8 port: no adaptor
1/2 port: TA261D-6-002 + SEAL-1/2
no table: to be confirmed
24,000 wall head (5/8 in. gas)not allowed by the table3/8 port: ADAPTOR3-5 + SEAL-3/8
1/2 port: TA261D-7-003 + SEAL-1/2
no table: to be confirmed
24,000 ducted head (1/2 in. gas)not allowed by the table3/8 port: TA261D-4-001 + SEAL-3/8
1/2 port: no adaptor
no table: to be confirmed
Total line set60 m70 m80 m
Total height20 m20 m23 m
Chargeless / extra charge per metre30 m / 12 g/m30 m / 12 g/mnot published
MCA / MOP19 / 35 A24 / 40 A30 / 50 A (3 to 5 heads)
Cabinet850 × 800 × 298 mm
52 kg (Hitachi’s sheet also says 121 lb)
850 × 800 × 298 mm
74 kg
950 × 945 × 370 mm
98 kg

Every 7,000 to 12,000 head, and the 18,000 mini-cassette, has a 3/8 in. gas line: no adaptor on a 3/8 in. port. “24,000” mini-cassette: the guide gives 1/2 in., the brochure 3/8 in.; we check the connection during the visit. Adaptors supplied with the outdoor unit (technical guide, section 13.1, which does not cover the RAM-G42N5HAA); Hitachi does not publish the rule for which head goes on which port. Lines, electrical and cabinets: airHome Multi brochures.

05 · Two, three or four

Three zones: between two and four rooms.

Three rooms is the last count where a cold-climate unit is still possible. One room fewer or more, and the numbers change.

One room fewer2 zones: the RAM-G18N2HAA comes in

Four possible units instead of three, including the $745 RAM-G18N2HAA and its 7,000 to 12,000 heads. The LogisVert spread widens, $745 to $1,920, and the RAM-G42N5HAA drops to the 25 / 40 A tier. The 2-zone page

One more room4 zones: the RAM-G24N3HAA drops out

Only the RAM-G36N4HAA and the RAM-G42N5HAA remain, neither cold climate: the top amount drops to $1,500. The RAM-G36N4HAA table lists 28 quadruples; the RAM-G42N5HAA has no table. The 4-zone page

What stays the sameThe -20°C heating limit

The three units on this page heat down to -20°C according to Hitachi, like the whole airHome Multi range. The number of rooms changes which units are possible, not the cold they handle. Winter, on the airHome Multi page

06 · Our installations

16 three-zone systems, from Senneville to Saint-Vincent-de-Paul.

Homes in the West Island, east-end Montréal and Laval, all published on our blog.

16three-zone installations

Published on our “Nos réalisations” blog as of Oct. 28, 2026. Here are the places, then four of those articles.

The 16 places published as of Oct. 28, 2026
Laval-des-RapidesMercier–Hochelaga-MaisonneuveMontréal-EstMontréal-NordOutremontPierrefonds-RoxboroPointe-ClaireRivière-des-Prairies–Pointe-aux-TremblesRosemont–La Petite-PatrieSaint-LaurentSaint-LéonardSainte-Anne-de-BellevueSainte-RoseSaint-Vincent-de-PaulSennevilleVimont
07 · Frequently asked questions

Your 3-zone questions, answered.

Because it is the only ENERGY STAR Cold Climate unit. Hydro-Québec pays $120 per 1,000 BTU/h certified at -8.3°C: 16 × $120 = $1,920. The RAM-G36N4HAA, certified at 25,000 BTU/h but without the cold-climate designation, gets $50: 25 × $50 = $1,250.

08 · The HITACHI space

One room more or less, or the whole range.

Sources, with the date we read them

  1. Hitachi (Johnson Controls Hitachi Air Conditioning), airHome Multi brochure “Multi-Split Inverter Heat Pump System”, EN “February 2025_CA”, read Oct. 14, 2026.
  2. Hitachi, airHome Multi brochure (FR), “December 2024_CA”, read Oct. 14, 2026.
  3. Hitachi, technical guide “TC_ NA airHome Multi-2024 (EN) - 00”, 183 pages: defrost factors 3.4, adaptors 13.1, read Oct. 14, 2026; combination tables 3.5 to 3.7 and model lists by size (PDF p. 58 to 67), re-read in full Oct. 28, 2026.
  4. NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org), records by AHRI number, read Oct. 14, 2026 and re-checked Oct. 28, 2026.
  5. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), read Oct. 14, 2026 and re-checked Oct. 28, 2026. For airHome units, the “markets” field lists the United States.
  6. Hydro-Québec, LogisVert eligible heat pump search tool (homeowner list), read Oct. 14, 2026; amounts recomputed Oct. 28, 2026 from the ENERGY STAR and NEEP certificates, at the rate of LogisVert guide v1.10.
  7. Hydro-Québec, residential LogisVert participant’s guide, version 1.10, September 15, 2026.
  8. Hitachi Cooling & Heating Canada, “Warranties & Training” page (mini-split systems), read Oct. 14, 2026.
  9. AirGreen, “Nos réalisations” blog, Hitachi articles published as of Oct. 28, 2026.

LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.