AirGreenHITACHI
HITACHI COOLING & HEATING · airHome Multi · 5 zonesThe HITACHI space at AirGreenFive rooms on a single RAM-G42N5HAA, sold and installed by AirGreen.
All of HITACHI
Free in-home estimate1 system · 5 heads
HITACHI airHome Multi · 5 zones · updated October 28, 2026

HITACHI 5-zone heat pump: a single RAM-G42N5HAA, and no published combination table

Five rooms, a single possible outdoor unit: the RAM-G42N5HAA, 42,000 BTU/h, five connections. It is in both airHome Multi brochures, but not in the technical guide: no combination table, no capacity window. So we confirm each combination with the distributor. The essentials of what Hitachi and NEEP publish are here.

HITACHI5 zones

RAM-G42N5HAA

Three configurations, three certificates. Indicative LogisVert.

5connections, all taken
80 mof line set in total, the most in the range
$1,500LogisVert, all non-ducted
0published combination table
The HITACHI shop · airHome Multi · 5 zones

The 5-zone system, right below.

RAM-G42N5HAA with five wall heads. As with any combination on this unit, the sizes of your five heads are confirmed with the distributor before the quotation.

AirGreenHITACHI
01 · Planner

Five rooms: the planner can only say “to be confirmed”.

Set your five heads. With no published table, the planner cannot validate any combination on the RAM-G42N5HAA; it does show the certificate, the indicative LogisVert amount and the electrical values for each configuration, and why the three other units are out.

Example homes
Living roomWall · 12,000 BTU/h
Bedroom 1Wall · 9,000 BTU/h
Bedroom 2Wall · 9,000 BTU/h
Bedroom 3Wall · 9,000 BTU/h
OfficeWall · 7,000 BTU/h
ConfigurationAll non-ducted
Total connected46,000 BTU/h

No unit with a published table takes these rooms. The RAM-G42N5HAA is confirmed with the distributor.

Not allowedRAM-G18N2HAA18,000 BTU/h · 2 connections · heads 7,000 to 12,000

Only 2 connections: 5 rooms do not fit.

AHRI216097706
ENERGY STAR (US market)
$745Indicative LogisVert

MCA / MOP · 50 m of line set in total

Not allowedRAM-G24N3HAA24,000 BTU/h · 3 connections · heads 7,000 to 18,000

Only 3 connections: 5 rooms do not fit.

AHRI216097707
ENERGY STAR Cold Climate (US market)Most Efficient
$1,920Indicative LogisVert

MCA / MOP · 60 m of line set in total

Not allowedRAM-G36N4HAA36,000 BTU/h · 4 connections · heads 7,000 to 24,000

Only 4 connections: 5 rooms do not fit.

AHRI216097708
ENERGY STAR (US market)
$1,250Indicative LogisVert

MCA / MOP · 70 m of line set in total

To be confirmedRAM-G42N5HAA42,000 BTU/h · 5 connections · no published table

Hitachi publishes no combination table for this unit: we confirm each combination with the distributor.

AHRI215827114
ENERGY STAR (US market)
$1,500Indicative LogisVert, if the combination is confirmed

MCA / MOP 30 / 50 A · 80 m of line set in total

See this system in our shop

RAM-G42N5HAA: Hitachi publishes no combination table; we confirm each combination with the distributor. The three other units do not have five connections. Mini-cassettes and floor consoles count as non-ducted in the certificates; a RAD-GJ ducted head changes the AHRI number. Example sizes: each room’s size is worked out during the visit. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.

02 · Published, not published

What Hitachi publishes for the RAM-G42N5HAA, and what is missing.

The RAM-G42N5HAA is in both airHome Multi brochures and on the NEEP list, but not in the technical guide, the one that holds the combination tables of the three other units. Here are both columns, with nothing rounded off.

publishedIndoor connections5
publishedLiquid ports · gas ports1/4 in. × 5 · 3/8 in. × 3 + 1/2 in. × 2
publishedTotal line set80 m (262 ft)
publishedPer branch, max and min25 m · 5 m
publishedTotal height23 m, the only one in the range above 20 m
publishedBetween two heads, height5 m
publishedMCA / MOP30 / 50 A with 3 to 5 heads · 25 / 40 A with 2 heads
publishedPower supply208-230 V, single phase, 60 Hz
publishedCabinet950 × 945 × 370 mm · 37.4 × 37.2 × 14.6 in.
publishedNet · gross weight98 kg · 105 kg
publishedDrain26 mm (1.02 in.)
publishedOutdoor sound, high58 dB(A)
publishedOperating rangeheating -20 to 24°C · cooling -10 to 46°C
publishedNEEP certificates215827114 · 217512354 · 215827115
publishedSEER2 · EER2 · HSPF2 IV23 · 12.5 · 9.2
not publishedCombination tablenone, in neither the brochures nor the technical guide
not publishedMinimum and maximum connectable headsrow missing
not publishedConnected-capacity windowmissing
not publishedChargeless length, extra charge per metremissing
not publishedFactory chargemissing
not publishedRecommended fuse, running currentsmissing
not publishedCooling and heating sound, sound powermissing
not publishedCompressor oilmissing
not publishedInstallation manualnot found
not publishedPort rule: which head on which portmissing for the whole range

Published: airHome Multi brochures EN (February 2025) and FR (December 2024), NEEP certificates. “Per branch” and “between two heads”: our reading of Hitachi’s labels, which it does not define. Not published: searched in both brochures, the 183-page technical guide and Hitachi’s documentation portal, on Oct. 14, 2026.

03 · Certified figures

From the certified figure at 8.3°C to the -20°C limit.

At 8.3°C, NEEP certifies up to 51,000 BTU/h. At -20°C, the coldest point of its certificate, 24,500 remain, with a COP of 1.8. It is the highest heat at -20°C in the airHome Multi range.

8.3°C51,000 BTU/h · rated 45,000 · COP 3.25
-8.3°C36,000 BTU/h · rated 30,000 · COP 2.29
-15°C29,500 BTU/h · rated 29,400 · COP 2
-20°C24,500 BTU/h · COP 1.8

Maximum certified capacity (NEEP, certificate 215827114, all non-ducted), rated certified capacity and COP at maximum.

Two figures at -8.3°C30,000 certified, 29,000 printed

The brochure prints 29,000 BTU/h at 17°F. The certificate says 30,000, and Hydro-Québec computes on that figure: 30 × $50 = $1,500.

Two figures in Region VHSPF2 7.29 / 7.2

NEEP certifies 7.29; Hitachi’s brochure prints 7.2.

The “sold in” fieldUSA and Canada, per NEEP

NEEP’s “sold in” field, which is for information only, gives the USA and Canada for the RAM-G42N5HAA’s three certificates. On the ENERGY STAR side, the listed market is still the United States.

04 · Three certificates

$1,500, or nothing at all.

Five wall, mini-cassette or floor heads: certificate 215827114, ENERGY STAR (US market), $1,500. A single ducted head among the five, and the system moves to the mixed certificate, which is not on the ENERGY STAR list: no more LogisVert grant.

All non-ducted · wall, mini-cassette, floor headsAHRI 215827114
ENERGY STAR (US market)
ENERGY STAR3712002
SEER2 / EER223 / 12.5
HSPF2 IV / V9.2 / 7.29
Certified at -8.3°C30,000 BTU/h
$1,50030 × $50 = $1,500
Mixed · at least one ducted head and one otherAHRI 217512354
Not on the ENERGY STAR list
ENERGY STARnot on the list
SEER2 / EER220.5 / 11.25
HSPF2 IV / V9.1 / 7.2
Certified at -8.3°C30,600 BTU/h
$0no LogisVert grant
All ducted · every head a RAD-GJAHRI 215827115
Not on the ENERGY STAR list
ENERGY STARnot on the list
SEER2 / EER218 / 10
HSPF2 IV / V9 / 7.11
Certified at -8.3°C31,400 BTU/h
$0no LogisVert grant

NEEP and ENERGY STAR certificates re-checked Oct. 28, 2026; indicative LogisVert, list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates.

05 · Installation

The largest cabinet in the range, and 23 m of height.

950 mm wide, 945 mm tall, 98 kg: the RAM-G42N5HAA is the only one of its size. It also takes the longest line network, 80 m in total, and the greatest height, 23 m.

The cabinets to scale, front view (mm)

Width × height, airHome Multi brochures. Depth: 298 mm for the other three, 370 mm for the RAM-G42N5HAA.

Five gas ports
3/83/83/81/21/2

Three 3/8 in. ports and two 1/2 in. ports, all taken with five heads. The guide that lists the supplied adaptors does not cover the RAM-G42N5HAA: we confirm the adaptors with the distributor, and Hitachi does not publish the rule for which head goes on which port.

Snow

A snow protection accessory is available per the brochure, with no published part number. We choose the stand and its height during the visit, for a 98 kg unit with a 26 mm drain.

06 · Four or five

Five zones or four: a table, or none.

One room fewer, and the RAM-G36N4HAA returns. At five, only the RAM-G42N5HAA is left.

One room fewer4 zones: the RAM-G36N4HAA and its table

With four rooms, the RAM-G36N4HAA comes in, with 28 quadruples published in its table, 24 / 40 A, a 25 A fuse and $1,250 of LogisVert. The 4-zone page

Five roomsAll five connections taken

One head per connection: with five rooms, the RAM-G42N5HAA has no free spot left. A sixth room would need a second outdoor unit.

The electrical supply30 / 50 A from three heads

From three to five heads, Hitachi prints the same tier for the RAM-G42N5HAA, 30 / 50 A (MCA / MOP): going from four to five rooms does not change the circuit at the panel.

07 · Frequently asked questions

Your 5-zone questions, answered.

Because Hitachi publishes no combination table for the RAM-G42N5HAA, the only unit with five connections. We confirm each combination with the distributor before the quotation.

08 · The HITACHI space

One room fewer, or the whole range.

Sources, with the date we read them

  1. Hitachi (Johnson Controls Hitachi Air Conditioning), airHome Multi brochure “Multi-Split Inverter Heat Pump System”, EN “February 2025_CA”, read Oct. 14, 2026.
  2. Hitachi, airHome Multi brochure (FR), “December 2024_CA”, read Oct. 14, 2026.
  3. Hitachi, technical guide “TC_ NA airHome Multi-2024 (EN) - 00”, 183 pages: defrost factors 3.4, adaptors 13.1, read Oct. 14, 2026; combination tables 3.5 to 3.7 and model lists by size (PDF p. 58 to 67), re-read in full Oct. 28, 2026.
  4. Hitachi, documentation portal: “airHome Multi (for NA) RAM-G-N-HAA” page inaccessible and installation guides searched, Oct. 14, 2026.
  5. NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org), records by AHRI number, read Oct. 14, 2026 and re-checked Oct. 28, 2026.
  6. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), read Oct. 14, 2026 and re-checked Oct. 28, 2026. For airHome units, the “markets” field lists the United States.
  7. Hydro-Québec, LogisVert eligible heat pump search tool (homeowner list), read Oct. 14, 2026; amounts recomputed Oct. 28, 2026 from the ENERGY STAR and NEEP certificates, at the rate of LogisVert guide v1.10.
  8. Hydro-Québec, residential LogisVert participant’s guide, version 1.10, September 15, 2026.
  9. Hitachi Cooling & Heating Canada, “Warranties & Training” page (mini-split systems), read Oct. 14, 2026.
  10. AirGreen, “Nos réalisations” blog, Hitachi articles published as of Oct. 28, 2026.

LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.