Only 2 connections: 5 rooms do not fit.
MCA / MOP · 50 m of line set in total
See this system in our shopFive rooms, a single possible outdoor unit: the RAM-G42N5HAA, 42,000 BTU/h, five connections. It is in both airHome Multi brochures, but not in the technical guide: no combination table, no capacity window. So we confirm each combination with the distributor. The essentials of what Hitachi and NEEP publish are here.
Three configurations, three certificates. Indicative LogisVert.
RAM-G42N5HAA with five wall heads. As with any combination on this unit, the sizes of your five heads are confirmed with the distributor before the quotation.
Set your five heads. With no published table, the planner cannot validate any combination on the RAM-G42N5HAA; it does show the certificate, the indicative LogisVert amount and the electrical values for each configuration, and why the three other units are out.
No unit with a published table takes these rooms. The RAM-G42N5HAA is confirmed with the distributor.
Only 2 connections: 5 rooms do not fit.
MCA / MOP · 50 m of line set in total
See this system in our shopOnly 3 connections: 5 rooms do not fit.
MCA / MOP · 60 m of line set in total
See this system in our shopOnly 4 connections: 5 rooms do not fit.
MCA / MOP · 70 m of line set in total
See this system in our shopHitachi publishes no combination table for this unit: we confirm each combination with the distributor.
MCA / MOP 30 / 50 A · 80 m of line set in total
See this system in our shopRAM-G42N5HAA: Hitachi publishes no combination table; we confirm each combination with the distributor. The three other units do not have five connections. Mini-cassettes and floor consoles count as non-ducted in the certificates; a RAD-GJ ducted head changes the AHRI number. Example sizes: each room’s size is worked out during the visit. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.
The RAM-G42N5HAA is in both airHome Multi brochures and on the NEEP list, but not in the technical guide, the one that holds the combination tables of the three other units. Here are both columns, with nothing rounded off.
Published: airHome Multi brochures EN (February 2025) and FR (December 2024), NEEP certificates. “Per branch” and “between two heads”: our reading of Hitachi’s labels, which it does not define. Not published: searched in both brochures, the 183-page technical guide and Hitachi’s documentation portal, on Oct. 14, 2026.
At 8.3°C, NEEP certifies up to 51,000 BTU/h. At -20°C, the coldest point of its certificate, 24,500 remain, with a COP of 1.8. It is the highest heat at -20°C in the airHome Multi range.
Maximum certified capacity (NEEP, certificate 215827114, all non-ducted), rated certified capacity and COP at maximum.
The brochure prints 29,000 BTU/h at 17°F. The certificate says 30,000, and Hydro-Québec computes on that figure: 30 × $50 = $1,500.
NEEP certifies 7.29; Hitachi’s brochure prints 7.2.
NEEP’s “sold in” field, which is for information only, gives the USA and Canada for the RAM-G42N5HAA’s three certificates. On the ENERGY STAR side, the listed market is still the United States.
Five wall, mini-cassette or floor heads: certificate 215827114, ENERGY STAR (US market), $1,500. A single ducted head among the five, and the system moves to the mixed certificate, which is not on the ENERGY STAR list: no more LogisVert grant.
NEEP and ENERGY STAR certificates re-checked Oct. 28, 2026; indicative LogisVert, list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates.
950 mm wide, 945 mm tall, 98 kg: the RAM-G42N5HAA is the only one of its size. It also takes the longest line network, 80 m in total, and the greatest height, 23 m.
Width × height, airHome Multi brochures. Depth: 298 mm for the other three, 370 mm for the RAM-G42N5HAA.
Three 3/8 in. ports and two 1/2 in. ports, all taken with five heads. The guide that lists the supplied adaptors does not cover the RAM-G42N5HAA: we confirm the adaptors with the distributor, and Hitachi does not publish the rule for which head goes on which port.
A snow protection accessory is available per the brochure, with no published part number. We choose the stand and its height during the visit, for a 98 kg unit with a 26 mm drain.
One room fewer, and the RAM-G36N4HAA returns. At five, only the RAM-G42N5HAA is left.
With four rooms, the RAM-G36N4HAA comes in, with 28 quadruples published in its table, 24 / 40 A, a 25 A fuse and $1,250 of LogisVert. The 4-zone page
One head per connection: with five rooms, the RAM-G42N5HAA has no free spot left. A sixth room would need a second outdoor unit.
From three to five heads, Hitachi prints the same tier for the RAM-G42N5HAA, 30 / 50 A (MCA / MOP): going from four to five rooms does not change the circuit at the panel.
Because Hitachi publishes no combination table for the RAM-G42N5HAA, the only unit with five connections. We confirm each combination with the distributor before the quotation.
Hitachi does not publish it: neither allowed sizes nor total connected capacity. Our 5-zone system in the shop comes with wall heads; as with any combination on this unit, their sizes are confirmed with the distributor before the quotation.
No. It is on the ENERGY STAR list (US market) without the cold-climate designation: LogisVert pays $50 per 1,000 BTU/h, so 30 × $50 = $1,500. It heats down to -20°C according to Hitachi, with 24,500 BTU/h certified at that point.
The system moves to the mixed certificate 217512354 (or all-ducted 215827115), not on the ENERGY STAR list: no LogisVert grant. A mini-cassette or a floor console keeps the non-ducted certificate.
Hitachi gives a 30 A minimum circuit ampacity (MCA) and a 50 A maximum overcurrent protection (MOP) with 3 to 5 heads. The recommended fuse is not published for this unit. We check your panel during the visit.
The cabinet measures 950 × 945 × 370 mm and weighs 98 kg, with a 26 mm drain. We found no published clearances for this unit: we choose the location and the stand during the visit.
Not yet: as of Oct. 28, 2026, our blog has no 5-zone article. During the visit, we show you what changes with five heads: 30 / 50 A at the panel, up to 80 m of line set and a 98 kg cabinet.
Hitachi and AirGreen warranties: explained once for the whole brand, on the HITACHI page.
No question matches. Call us at 514 316-2973.
During the visit, we measure the five rooms, then submit your combination to the distributor. The quotation comes with the confirmed combination, its AHRI number and its indicative LogisVert amount.
Hydro-Québec never solicits anyone by phone or door to door for LogisVert. If someone calls “on behalf of Hydro-Québec” to sell you a heat pump, hang up.
Monday to Thursday 8 a.m. to 6 p.m. · Friday 8 a.m. to 4 p.m.








LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.