AirGreen × GENERAL AIRSTAGE
Sold and installed by AirGreen.
Montreal, Laval, Longueuil, the North Shore and the South Shore.
GENERAL AIRSTAGE // LMAH · R-410A
LMAH: the LMAS indoor unit, with an outdoor unit that has a NEEP point at −26 °C
2 sizes, 9,000 and 12,000 BTU, on R-410A. The LMAH keeps the ASUH..LMAS indoor unit and changes the outdoor unit: −26 °C is the coldest point on its NEEP listing, and GENERAL's XLTH series page states −15 °F (−26 °C) for this group, with no table per model. Our product pages give −15 °C for the LMAS.
R-32 at GENERAL
At −26 °C, the Orion XLTH at 9,000 and 12,000
On R-32, GENERAL's series closest to the LMAH, at the same sizes and down to −26 °C, is the Orion XLTH.
Orion XLTH AOUH12KZAH1
- Refrigerant
- R-32
- At −26 °C, maximum (NEEP)
- 12,200 BTU/h
- COP at that point
- 1.81
LMAH AOUH12LMAH1
- Refrigerant
- R-410A
- At −26 °C, maximum (NEEP)
- 6,180 BTU/h
- COP at that point
- 1.40
At 12,000 and −26 °C, on the NEEP listings: at most 12,200 BTU/h for the Orion XLTH, 6,180 BTU/h for the LMAH.
The tool // Three series side by side
Pick the size, the temperature and the comparison: the R-32 Orion XLTH, or the LMAS
The Orion XLTH is GENERAL's R-32 series that also reaches −26 °C at 9,000 and 12,000. Against the generation H LMAS, the LMAH keeps the same ASUH..LMAS indoor unit; its outdoor unit adds the −26 °C point and, at 12,000, higher rated heating at −8.3 °C. At −15 °C, on the other hand, the LMAH 9,000 gives less than the LMAS (9,400 vs 10,100 BTU/h rated) and the 12,000 has a lower COP at maximum (2.27 vs 2.45).
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 23,000 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.08
LMAH AOUH09LMAH1 · R-410A
- Maximum heating
- 16,000 BTU/h
- Rated heating
- 9,000 BTU/h
- COP at maximum
- 2.81
At 8.3 °C, at maximum, the Orion XLTH gives 7,000 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 3.08 and the LMAH at 2.81.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 17,500 BTU/h
- Rated heating
- 7,500 BTU/h
- COP at maximum
- 2.49
LMAH AOUH09LMAH1 · R-410A
- Maximum heating
- 10,550 BTU/h
- Rated heating
- 7,400 BTU/h
- COP at maximum
- 2.22
At −8.3 °C, at maximum, the Orion XLTH gives 6,950 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 2.49 and the LMAH at 2.22.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 15,400 BTU/h
- Rated heating
- 15,400 BTU/h
- COP at maximum
- 2.26
LMAH AOUH09LMAH1 · R-410A
- Maximum heating
- 9,400 BTU/h
- Rated heating
- 9,400 BTU/h
- COP at maximum
- 2.01
At −15 °C, at maximum, the Orion XLTH gives 6,000 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 2.26 and the LMAH at 2.01.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 11,400 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.70
LMAH AOUH09LMAH1 · R-410A
- Maximum heating
- 5,470 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.24
At −26 °C, at maximum, the Orion XLTH gives 5,930 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 1.70 and the LMAH at 1.24.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 23,600 BTU/h
- Rated heating
- 16,000 BTU/h
- COP at maximum
- 3.07
LMAH AOUH12LMAH1 · R-410A
- Maximum heating
- 19,100 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.35
At 8.3 °C, at maximum, the Orion XLTH gives 4,500 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 3.07 and the LMAH at 3.35.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 18,700 BTU/h
- Rated heating
- 10,000 BTU/h
- COP at maximum
- 2.44
LMAH AOUH12LMAH1 · R-410A
- Maximum heating
- 12,700 BTU/h
- Rated heating
- 10,300 BTU/h
- COP at maximum
- 2.68
At −8.3 °C, at maximum, the Orion XLTH gives 6,000 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 2.44 and the LMAH at 2.68.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 16,600 BTU/h
- Rated heating
- 16,600 BTU/h
- COP at maximum
- 2.16
LMAH AOUH12LMAH1 · R-410A
- Maximum heating
- 10,700 BTU/h
- Rated heating
- 10,300 BTU/h
- COP at maximum
- 2.27
At −15 °C, at maximum, the Orion XLTH gives 5,900 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 2.16 and the LMAH at 2.27.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 12,200 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.81
LMAH AOUH12LMAH1 · R-410A
- Maximum heating
- 6,180 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.40
At −26 °C, at maximum, the Orion XLTH gives 6,020 BTU/h more than the LMAH. At maximum, the Orion XLTH runs at a COP of 1.81 and the LMAH at 1.40.
LMAH AOUH09LMAH1
- Maximum heating
- 16,000 BTU/h
- Rated heating
- 9,000 BTU/h
- COP at maximum
- 2.81
LMAS AOUH09LMAS1
- Maximum heating
- 15,000 BTU/h
- Rated heating
- 9,000 BTU/h
- COP at maximum
- 2.73
At 8.3 °C, at maximum, the LMAH gives 1,000 BTU/h more than the LMAS.
LMAH AOUH09LMAH1
- Maximum heating
- 10,550 BTU/h
- Rated heating
- 7,400 BTU/h
- COP at maximum
- 2.22
LMAS AOUH09LMAS1
- Maximum heating
- 10,100 BTU/h
- Rated heating
- 7,400 BTU/h
- COP at maximum
- 2.21
At −8.3 °C, at maximum, the LMAH gives 450 BTU/h more than the LMAS.
LMAH AOUH09LMAH1
- Maximum heating
- 9,400 BTU/h
- Rated heating
- 9,400 BTU/h
- COP at maximum
- 2.01
LMAS AOUH09LMAS1
- Maximum heating
- 10,200 BTU/h
- Rated heating
- 10,100 BTU/h
- COP at maximum
- 2.35
At −15 °C, at maximum, the LMAS gives 800 BTU/h more than the LMAH. In rated heating, the LMAS is ahead: 10,100 BTU/h vs 9,400.
LMAH AOUH09LMAH1
- Maximum heating
- 5,470 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.24
LMAS AOUH09LMAS1
- At −26 °C
- not published
- Its limit (our product pages)
- −15 °C
- Maximum at −15 °C
- 10,200 BTU/h
At −26 °C, only the LMAH has a published value: 5,470 BTU/h at maximum, COP 1.24, that is 61% of its rated heating at 8.3 °C.
LMAH AOUH12LMAH1
- Maximum heating
- 19,100 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.35
LMAS AOUH12LMAS1
- Maximum heating
- 19,100 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.35
At 8.3 °C, the same maximum heating on the listings: 19,100 BTU/h.
LMAH AOUH12LMAH1
- Maximum heating
- 12,700 BTU/h
- Rated heating
- 10,300 BTU/h
- COP at maximum
- 2.68
LMAS AOUH12LMAS1
- Maximum heating
- 12,700 BTU/h
- Rated heating
- 8,800 BTU/h
- COP at maximum
- 2.68
At −8.3 °C, the same maximum heating on the listings: 12,700 BTU/h. In rated heating, the LMAH is ahead: 10,300 BTU/h vs 8,800.
LMAH AOUH12LMAH1
- Maximum heating
- 10,700 BTU/h
- Rated heating
- 10,300 BTU/h
- COP at maximum
- 2.27
LMAS AOUH12LMAS1
- Maximum heating
- 10,700 BTU/h
- Rated heating
- 10,300 BTU/h
- COP at maximum
- 2.45
At −15 °C, the same maximum heating on the listings: 10,700 BTU/h.
LMAH AOUH12LMAH1
- Maximum heating
- 6,180 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.40
LMAS AOUH12LMAS1
- At −26 °C
- not published
- Its limit (our product pages)
- −15 °C
- Maximum at −15 °C
- 10,700 BTU/h
At −26 °C, only the LMAH has a published value: 6,180 BTU/h at maximum, COP 1.40, that is 52% of its rated heating at 8.3 °C.
NEEP listings 392121 and 392122 (Orion XLTH), 438620 and 438621 (LMAH) and 438528 and 438529 (LMAS, generation H), modified August 24, 2026 and checked November 5, 2026, at 21 °C indoors. The LMAS shown is the same generation H, which uses the same ASUH..LMAS indoor unit.
The two sizes
Each size at a glance
LMAH 9,000 BTU · AOUH09LMAH1
| Units | ASUH09LMAS / AOUH09LMAH1 |
|---|---|
| AHRI | 206263449 |
| NEEP listing | 438621 |
| ENERGY STAR Canada | 2409907 · cold climate |
| SEER2 · HSPF2 (IV) | 26.5 · 12.3 |
| At 8.3 °C, rated (min–max) | 9,000 BTU/h (2,800–16,000) |
| At −8.3 °C · at −15 °C, rated | 7,400 · 9,400 BTU/h |
| Coldest point on the listing | −26 °C: 5,470 BTU/h |
| Heating limit (NEEP point; XLTH series page) | −26 °C |
| Indoor sound, quiet speed (our product pages) | 19 dB(A) |
| LogisVert, indicative amount | $0 (under 12,000 BTU/h nominal) |
LMAH 12,000 BTU · AOUH12LMAH1
| Units | ASUH12LMAS / AOUH12LMAH1 |
|---|---|
| AHRI | 206263450 |
| NEEP listing | 438620 |
| ENERGY STAR Canada | 2417191 |
| SEER2 · HSPF2 (IV) | 23.0 · 11.2 |
| At 8.3 °C, rated (min–max) | 12,000 BTU/h (2,800–19,100) |
| At −8.3 °C · at −15 °C, rated | 10,300 · 10,300 BTU/h |
| Coldest point on the listing | −26 °C: 6,180 BTU/h |
| Heating limit (NEEP point; XLTH series page) | −26 °C |
| Indoor sound, quiet speed (our product pages) | 19 dB(A) |
| LogisVert, indicative amount | $515 |
The 9,000 is ENERGY STAR cold climate certified, the 12,000 ENERGY STAR without the cold-climate mention. Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.
The 2 LMAH online
Price by quote.
GENERAL // Did you know
Three details about the LMAH, from GENERAL's own documents
Did you know · The family
Under which label does GENERAL file the LMAH, and the LMAS?
Did you know · The letter
Does the LMAH come, like the LMAS, in generation G and generation H?
Did you know · The timers
Does the LMAH's ASUH..LMAS indoor unit have a weekly timer?
LogisVert
$0 or $515
The 9,000 is under the 12,000 BTU/h of nominal cooling the LogisVert guide v1.10 (September 15, 2026) requires: $0. The 12,000 is ENERGY STAR certified without the cold-climate mention: $50 per 1,000 BTU/h of heating at −8 °C, that is $515 as an indicative amount. The generation H LMAS 12,000, with 8,800 BTU/h rated at −8.3 °C, is at $440.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about the LMAH
What does the LMAH give at −26 °C?
On the NEEP listings, at maximum, 5,470 BTU/h for the 9,000 and 6,180 BTU/h for the 12,000, at a COP of 1.24 and 1.40: 61% and 52% of their rated heating at 8.3 °C. On the coldest nights the room will often need backup heat; we cover this during the on-site assessment.
LMAH or LMAS?
Same indoor unit. The LMAH NEEP listing goes down to −26 °C, as GENERAL's XLTH series page states for this group; our product pages give −15 °C for the LMAS. At 12,000 the LMAH also has higher rated heating at −8.3 °C (10,300 BTU/h vs 8,800), hence an indicative LogisVert amount of $515 vs $440. At 9,000 and −15 °C, it is the LMAS that gives more. Only Hydro-Québec confirms the assistance granted.
Is Wi-Fi included?
No: on this indoor unit, Wi-Fi needs an optional wireless adapter, according to GENERAL's manual.
LMAH 9,000 or 12,000: how is the choice made?
During the on-site assessment: the room, its insulation and its windows decide, and we only recommend a size after seeing them. On paper the 12,000 may be eligible for an indicative LogisVert amount and the 9,000 is not, but that is not what sets the size. Only Hydro-Québec confirms the assistance granted.
How much LogisVert for an LMAH?
$0 for the 9,000 and $515 for the 12,000, as indicative amounts. Only Hydro-Québec confirms the assistance granted.
An LMAH: the LMAS indoor unit, on the deep-cold side, installed by AirGreen.
On site we see the room and where the outdoor unit goes, then look with you at what the LMAH's −26 °C point changes, or does not change, for your winter. AHRI number and indicative LogisVert amount of the model chosen: on the quote.
Sold and installed by AirGreen.
See the Orion XLTH (R-32, −26 °C) · See the LMAS · See the LZAH (−26 °C, up to 15,000) · Compare the 13 wall series
Sources
Where the numbers come from
- GENERAL, ASU(G/H)09-12LMAS indoor unit operating manual, ref. 9387602104.
- GENERAL, XLTH and LMAS series pages and 09 and 12LMAH1 model pages (US site archive), read November 5, 2026.
- NEEP listings 438620 and 438621 (LMAH), 438528 and 438529 (LMAS), checked November 5, 2026.
- ENERGY STAR, Canadian market, records 2409907 and 2417191, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.
Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.