AirGreenGENERAL

AirGreen × GENERAL AIRSTAGE

Sold and installed by AirGreen.

Montreal, Laval, Longueuil, the North Shore and the South Shore.

GENERAL AIRSTAGE // Orion XLTH · KZAH

Orion XLTH: the GENERAL wall heat pump published down to −26 °C, from 9,000 to 24,000 BTU

5 sizes, from 9,000 to 24,000 BTU, on R-32, with a published heating range down to −26 °C and, according to GENERAL, no automatic low-temperature shut-off. It is the only GENERAL R-32 wall series that reaches −26 °C at 18,000 and 24,000 BTU.

5sizes online
−26 °Cpublished heating limit, with no automatic shut-off according to GENERAL
33.1SEER2, at 9,000 BTU
6indoor fan speeds, from "Quiet" to "High"
$1,908highest LogisVert, at 24,000 BTUIndicative amount. Only Hydro-Québec confirms the assistance granted.

The tool // Cold curve

Pick the size: here is how much heat the Orion XLTH keeps as it gets cold

Each size, from 8.3 °C down to −26 °C, next to a GENERAL R-410A wall unit that also reaches −26 °C at that size: the LZAH up to 15,000, the RLX FWH at 18,000 and 24,000.

Size, BTU
Orion XLTH AOUH12KZAH1 · R-32LZAH AOUG12LZAH1 · R-410Amaximum BTU/h · % = share of the same model's rated heating at 8.3 °C
8.3 °C

23,600 BTU/h 148%22,100 BTU/h 184%

−8.3 °C

18,700 BTU/h 117%17,500 BTU/h 146%

−15 °C

16,600 BTU/h 104%16,600 BTU/h 138%

−26 °C

12,200 BTU/h 76%11,800 BTU/h 98%

At −26 °C, at maximum, the Orion XLTH gives 400 BTU/h more than the same-size LZAH; COP at that point: 1.81 for the Orion XLTH, 1.55 for the LZAH. At 8.3 °C, the Orion XLTH has 16,000 BTU/h rated, vs 12,000 for the LZAH. SEER2: 30.5 for the Orion XLTH, 29.4 for the LZAH.

Maximum heating at the four points of the NEEP listings (8.3, −8.3, −15 and −26 °C), at 21 °C indoors: listings 392121 to 392123, 385841 and 385842 (Orion XLTH), 438610, 438612 and 438614 (LZAH), 438661 and 438662 (RLX FWH), modified August 24, 2026 and checked November 5, 2026. The share is computed on the same model's rated heating at 8.3 °C. GENERAL publishes the LZAH down to −26 °C in its submittals; for the RLX FWH, −26 °C is a NEEP point, which GENERAL's XLTH series page states for this group, with no table per model. A maximum is the most the unit can give, not what it gives all night.

The five sizes

Each size at a glance

Orion XLTH 9,000 BTU

UnitsASUH09KZAS / AOUH09KZAH1
AHRI214888800
NEEP listing392123
ENERGY STAR Canada3554344 · cold climate
SEER2 · HSPF2 (IV)33.1 · 13.3
At 8.3 °C, rated (min–max)12,000 BTU/h (3,500–23,000)
At −8.3 °C, rated · maximum7,500 · 17,500 BTU/h
At −15 °C, rated · maximum15,400 · 15,400 BTU/h
At −26 °C, maximum (COP)11,400 BTU/h (1.70)
Indoor sound, quiet speed23 dB(A)
LogisVert, indicative amount$0 (under 12,000 BTU/h nominal)

Orion XLTH 12,000 BTU

UnitsASUH12KZAS / AOUH12KZAH1
AHRI214888802
NEEP listing392122
ENERGY STAR Canada3554345 · cold climate
SEER2 · HSPF2 (IV)30.5 · 12.7
At 8.3 °C, rated (min–max)16,000 BTU/h (3,500–23,600)
At −8.3 °C, rated · maximum10,000 · 18,700 BTU/h
At −15 °C, rated · maximum16,600 · 16,600 BTU/h
At −26 °C, maximum (COP)12,200 BTU/h (1.81)
Indoor sound, quiet speed23 dB(A)
LogisVert, indicative amount$1,200

Orion XLTH 15,000 BTU

UnitsASUH15KZAS / AOUH15KZAH1
AHRI214888804
NEEP listing392121
ENERGY STAR Canada3554346 · cold climate
SEER2 · HSPF2 (IV)27.5 · 12.7
At 8.3 °C, rated (min–max)18,000 BTU/h (4,150–25,000)
At −8.3 °C, rated · maximum11,400 · 22,000 BTU/h
At −15 °C, rated · maximum21,000 · 21,000 BTU/h
At −26 °C, maximum (COP)16,400 BTU/h (1.92)
Indoor sound, quiet speed26 dB(A)
LogisVert, indicative amount$1,368

Orion XLTH 18,000 BTU

UnitsASUH18KZAS / AOUH18KZAH1
AHRI215647921
NEEP listing385842
ENERGY STAR Canada3629537 · cold climate
SEER2 · HSPF2 (IV)25.5 · 12.5
At 8.3 °C, rated (min–max)21,600 BTU/h (8,000–31,800)
At −8.3 °C, rated · maximum13,600 · 27,200 BTU/h
At −15 °C, rated · maximum24,800 · 25,400 BTU/h
At −26 °C, maximum (COP)19,110 BTU/h (1.65)
Indoor sound, quiet speed30 dB(A)
LogisVert, indicative amount$1,632

Orion XLTH 24,000 BTU

UnitsASUH24KZAS / AOUH24KZAH1
AHRI215647924
NEEP listing385841
ENERGY STAR Canada3629538 · cold climate
SEER2 · HSPF2 (IV)24.0 · 11.9
At 8.3 °C, rated (min–max)25,200 BTU/h (8,200–36,800)
At −8.3 °C, rated · maximum15,900 · 28,900 BTU/h
At −15 °C, rated · maximum25,200 · 25,800 BTU/h
At −26 °C, maximum (COP)19,110 BTU/h (1.65)
Indoor sound, quiet speed30 dB(A)
LogisVert, indicative amount$1,908

Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.

The 5 Orion XLTH online

Price by quote.

What changes from one size to the next

One series, two builds

9,000 to 15,000Indoor unit 280 × 980 × 240 mm, 12.5 kg; 1/4 in liquid line.
18,000 and 24,000Indoor unit 340 × 1,150 × 280 mm, 16.5 kg; 3/8 and 5/8 in lines.
Quiet speed23 dB(A) at 9,000 and 12,000, 26 at 15,000, 30 at 18,000 and 24,000, indoors.
Top speed43 to 44 dB(A) at 9,000 and 12,000, up to 47 dB(A) at 24,000 in heating, indoors.

Source: GENERAL design and technical manual DR_AS233ES, p. 2 to 5, levels measured in an anechoic chamber.

GENERAL // Did you know

Three details about the Orion XLTH, from GENERAL's own documents

Did you know · The rating

Over what line length does GENERAL rate the Orion XLTH's capacities?

Did you know · The drain

What does the manual provide for the indoor unit's drain hose?

Did you know · The room

Up to what indoor temperature can the Orion XLTH heat?

LogisVert

From $0 to $1,908 depending on size

Every Orion XLTH carries the ENERGY STAR cold climate mark for Canada (records 3554344 to 3554346, 3629537 and 3629538). The LogisVert guide v1.10 (September 15, 2026) therefore counts $120 per 1,000 BTU/h of heating at −8 °C: $1,200 at 12,000, $1,368 at 15,000, $1,632 at 18,000 and $1,908 at 24,000, as indicative amounts.

Nothing for the 9,000: its outdoor unit stays under the 12,000 BTU/h of nominal cooling the guide requires.

These are indicative amounts. Only Hydro-Québec confirms the assistance granted.

The LogisVert rules, explained by AirGreen

Questions

What people ask us about the Orion XLTH

Does it really heat down to −26 °C?

Yes: −26 °C is its published heating limit, and GENERAL states it has no automatic low-temperature shut-off. On the NEEP listings at −26 °C, maximum heating runs from 11,400 BTU/h (9,000) to 19,110 BTU/h (18,000 and 24,000). As a share of rated heating at 8.3 °C, that is from 76% (12,000 and 24,000) to 95% (9,000).

Orion XLTH or Orion XLTH+?

The Orion XLTH+ goes lower (−30 °C published vs −26 °C) but stops at 15,000 BTU. The Orion XLTH goes up to 24,000 BTU. At 12,000, the Orion XLTH has slightly higher rated heating at −15 °C (16,600 BTU/h vs 16,200), the Orion XLTH+ a higher maximum (20,500 BTU/h vs 16,600).

Orion XLTH 15,000 or 18,000: how is it decided?

After seeing the room, its insulation and its windows: the room sets the size, and we only recommend one after the visit. Those two sizes do not share an indoor unit, 980 mm wide for one, 1,150 mm for the other, which also matters for the wall.

Is Wi-Fi included?

Yes, it is built into the indoor unit, for the AIRSTAGE Mobile app. The standard control is a wireless remote; a wired controller is an option.

Is it quiet?

At quiet speed, GENERAL's manual gives 23 dB(A) in the room at 9,000 and 12,000, 26 at 15,000 and 30 at 18,000 and 24,000: on the Québec.ca scale, between "whispers heard a metre away" (20 dB(A)) and "a low-voice conversation" (30 dB(A)). The outdoor unit, which is louder, is placed with you away from bedroom windows.

How much LogisVert for an Orion XLTH?

From $0 (9,000, under the 12,000 BTU/h nominal minimum) to $1,908 (24,000), as indicative amounts. Only Hydro-Québec confirms the assistance granted.

AirGreenGENERAL

An Orion XLTH for winters that reach −26 °C, installed by AirGreen.

At your home we measure the wall for the indoor unit, 980 or 1,150 mm wide depending on size, and choose with you where the outdoor unit goes. The size is decided then; the quote then carries the AHRI number and indicative LogisVert amount of the model chosen.

Sold and installed by AirGreen.

See the Orion XLTH+ (−30 °C) · Compare with the 12 other wall series · See the LZAH (R-410A)

Sources

Where the numbers come from

  1. GENERAL, Orion XLTH (KZAH1) series page, airstagehvac.com, read October 29, 2026 and reviewed November 5, 2026.
  2. GENERAL, design and technical manual "Wall mounted type", DR_AS233ES, January 17, 2025, p. 2 to 5 and 12.
  3. NEEP listings 392121, 392122, 392123, 385841 and 385842 (Orion XLTH), 438610, 438612 and 438614 (LZAH), 438661 and 438662 (RLX FWH), modified August 24, 2026, checked November 5, 2026.
  4. ENERGY STAR, Canadian market, records 3554344, 3554345, 3554346, 3629537 and 3629538, checked November 5, 2026.
  5. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
  6. Government of Québec, "Noise measurement", Québec.ca, updated June 16, 2022.
  7. airgreen.ca product pages, read November 5, 2026.

Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.