GENERAL AIRSTAGE // Altair 500 · KPAS
Altair 500: the GENERAL R-32 wall heat pump in six sizes, from 9,000 to 36,000 BTU
6 sizes on R-32, published down to −15 °C, including GENERAL's only R-32 wall unit at 30,000 and 36,000 BTU. ENERGY STAR certified at every size, and cold climate from 18,000.
The tool // Size by size
Six sizes, three builds: pick a size
The Altair 500 changes build twice between 9,000 and 36,000 BTU, and becomes cold climate from 18,000.
Altair 500 9,000 BTU AOUH09KPAS1
- Indoor unit
- 270 × 834 × 222 mm, 9.5 kg
- Outdoor unit
- 541 × 663 × 290 mm, 23 kg
- Line set
- 3 to 20 m, 15 m pre-charged, 15 m height difference
- Cooling in cold weather
- down to −10 °C
- Quiet, cooling · heating
- 19 · 21 dB(A)
- ENERGY STAR Canada
- yes, without the cold-climate mention
- At −15 °C, rated (NEEP)
- 7,100 BTU/h
- LogisVert, indicative amount
- $0 (under 12,000 BTU/h nominal)
At 9,000, the Altair 500 is ENERGY STAR certified without the cold-climate mention: no LogisVert under 12,000 BTU/h of nominal cooling.
Altair 500 12,000 BTU AOUH12KPAS1
- Indoor unit
- 270 × 834 × 222 mm, 9.5 kg
- Outdoor unit
- 541 × 663 × 290 mm, 26 kg
- Line set
- 3 to 20 m, 15 m pre-charged, 15 m height difference
- Cooling in cold weather
- down to −10 °C
- Quiet, cooling · heating
- 19 · 21 dB(A)
- ENERGY STAR Canada
- yes, without the cold-climate mention
- At −15 °C, rated (NEEP)
- 8,500 BTU/h
- LogisVert, indicative amount
- $435
At 12,000, the Altair 500 is ENERGY STAR certified without the cold-climate mention: $50 per 1,000 BTU/h at −8 °C, that is $435 as an indicative amount.
Altair 500 18,000 BTU AOUH18KPAS1
- Indoor unit
- 280 × 980 × 240 mm, 12.5 kg
- Outdoor unit
- 632 × 799 × 290 mm, 39 kg
- Line set
- 3 to 30 m, 15 m pre-charged, 25 m height difference
- Cooling in cold weather
- down to −20 °C (special function)
- Quiet, cooling · heating
- 26 · 28 dB(A)
- ENERGY STAR Canada
- cold climate
- At −15 °C, rated (NEEP)
- 18,500 BTU/h
- LogisVert, indicative amount
- $1,356
From 18,000 the Altair 500 is cold climate certified: $120 per 1,000 BTU/h at −8 °C, that is $1,356 as an indicative amount for this size.
Altair 500 24,000 BTU AOUH24KPAS1
- Indoor unit
- 280 × 980 × 240 mm, 12.5 kg
- Outdoor unit
- 632 × 799 × 290 mm, 39 kg
- Line set
- 3 to 30 m, 15 m pre-charged, 25 m height difference
- Cooling in cold weather
- down to −20 °C (special function)
- Quiet, cooling · heating
- 31 · 32 dB(A)
- ENERGY STAR Canada
- cold climate
- At −15 °C, rated (NEEP)
- 20,000 BTU/h
- LogisVert, indicative amount
- $1,776
From 18,000 the Altair 500 is cold climate certified: $120 per 1,000 BTU/h at −8 °C, that is $1,776 as an indicative amount for this size.
Altair 500 30,000 BTU AOUH30KPAS1
- Indoor unit
- 340 × 1,150 × 280 mm, 16.5 kg
- Outdoor unit
- 788 × 940 × 320 mm, 53 kg
- Line set
- 5 to 50 m, 20 m pre-charged, 30 m height difference
- Cooling in cold weather
- down to −20 °C (special function)
- Quiet, cooling · heating
- 32 · 32 dB(A)
- ENERGY STAR Canada
- cold climate
- At −15 °C, rated (NEEP)
- 25,800 BTU/h
- LogisVert, indicative amount
- $2,352
From 18,000 the Altair 500 is cold climate certified: $120 per 1,000 BTU/h at −8 °C, that is $2,352 as an indicative amount for this size.
Altair 500 36,000 BTU AOUH36KPAS1
- Indoor unit
- 340 × 1,150 × 280 mm, 16.5 kg
- Outdoor unit
- 788 × 940 × 320 mm, 53 kg
- Line set
- 5 to 50 m, 20 m pre-charged, 30 m height difference
- Cooling in cold weather
- down to −20 °C (special function)
- Quiet, cooling · heating
- 32 · 32 dB(A)
- ENERGY STAR Canada
- cold climate
- At −15 °C, rated (NEEP)
- 25,800 BTU/h
- LogisVert, indicative amount
- $2,688
From 18,000 the Altair 500 is cold climate certified: $120 per 1,000 BTU/h at −8 °C, that is $2,688 as an indicative amount for this size.
Indoor dimensions and sound levels: design manual DR_AS237ES, November 13, 2024, p. 2, 4 and 6. Outdoor unit, line set and cooling down to −20 °C (18,000 to 36,000 only): 09 to 36KPAS1 submittals, version 20250409A. ENERGY STAR Canada and NEEP checked November 5, 2026. Indicative LogisVert amounts; only Hydro-Québec confirms the assistance granted.
The six sizes
Each size at a glance
Altair 500 9,000 BTU · AOUH09KPAS1
| Units | ASUH09KPAS / AOUH09KPAS1 |
|---|---|
| AHRI | 215212609 |
| NEEP listing | 392097 |
| ENERGY STAR Canada | 3554408 |
| SEER2 · HSPF2 (IV) | 26.0 · 10.8 |
| At 8.3 °C, rated (min–max) | 10,000 BTU/h (2,400–13,600) |
| At −8.3 °C · at −15 °C, rated | 6,400 · 7,100 BTU/h |
| Coldest point on the listing | −15 °C: 7,100 BTU/h |
| Heating limit published by GENERAL | −15 °C |
| Indoor sound, quiet speed | 19 dB(A) |
| LogisVert, indicative amount | $0 (under 12,000 BTU/h nominal) |
Altair 500 12,000 BTU · AOUH12KPAS1
| Units | ASUH12KPAS / AOUH12KPAS1 |
|---|---|
| AHRI | 215212610 |
| NEEP listing | 392096 |
| ENERGY STAR Canada | 3554409 |
| SEER2 · HSPF2 (IV) | 24.0 · 10.5 |
| At 8.3 °C, rated (min–max) | 14,000 BTU/h (2,700–17,000) |
| At −8.3 °C · at −15 °C, rated | 8,700 · 8,500 BTU/h |
| Coldest point on the listing | −15 °C: 8,500 BTU/h |
| Heating limit published by GENERAL | −15 °C |
| Indoor sound, quiet speed | 19 dB(A) |
| LogisVert, indicative amount | $435 |
Altair 500 18,000 BTU · AOUH18KPAS1
| Units | ASUH18KPAS / AOUH18KPAS1 |
|---|---|
| AHRI | 215441046 |
| NEEP listing | 388111 |
| ENERGY STAR Canada | 3627258 · cold climate |
| SEER2 · HSPF2 (IV) | 22.0 · 10.5 |
| At 8.3 °C, rated (min–max) | 18,000 BTU/h (4,150–24,000) |
| At −8.3 °C · at −15 °C, rated | 11,300 · 18,500 BTU/h |
| Coldest point on the listing | −15 °C: 18,500 BTU/h |
| Heating limit published by GENERAL | −15 °C |
| Indoor sound, quiet speed | 26 dB(A) |
| LogisVert, indicative amount | $1,356 |
Altair 500 24,000 BTU · AOUH24KPAS1
| Units | ASUH24KPAS / AOUH24KPAS1 |
|---|---|
| AHRI | 215441047 |
| NEEP listing | 388110 |
| ENERGY STAR Canada | 3627259 · cold climate |
| SEER2 · HSPF2 (IV) | 21.5 · 10.0 |
| At 8.3 °C, rated (min–max) | 24,000 BTU/h (4,150–28,500) |
| At −8.3 °C · at −15 °C, rated | 14,800 · 20,000 BTU/h |
| Coldest point on the listing | −15 °C: 20,000 BTU/h |
| Heating limit published by GENERAL | −15 °C |
| Indoor sound, quiet speed | 31 dB(A) |
| LogisVert, indicative amount | $1,776 |
Altair 500 30,000 BTU · AOUH30KPAS1
| Units | ASUH30KPAS / AOUH30KPAS1 |
|---|---|
| AHRI | 215390440 |
| NEEP listing | 389412 |
| ENERGY STAR Canada | 3629536 · cold climate |
| SEER2 · HSPF2 (IV) | 22.0 · 10.2 |
| At 8.3 °C, rated (min–max) | 30,000 BTU/h (9,200–34,800) |
| At −8.3 °C · at −15 °C, rated | 19,600 · 25,800 BTU/h |
| Coldest point on the listing | −15 °C: 25,800 BTU/h |
| Heating limit published by GENERAL | −15 °C |
| Indoor sound, quiet speed | 32 dB(A) |
| LogisVert, indicative amount | $2,352 |
Altair 500 36,000 BTU · AOUH36KPAS1
| Units | ASUH36KPAS / AOUH36KPAS1 |
|---|---|
| AHRI | 215390441 |
| NEEP listing | 389411 |
| ENERGY STAR Canada | 3621237 · cold climate |
| SEER2 · HSPF2 (IV) | 21.0 · 10.0 |
| At 8.3 °C, rated (min–max) | 34,000 BTU/h (9,200–36,800) |
| At −8.3 °C · at −15 °C, rated | 22,400 · 25,800 BTU/h |
| Coldest point on the listing | −15 °C: 25,800 BTU/h |
| Heating limit published by GENERAL | −15 °C |
| Indoor sound, quiet speed | 32 dB(A) |
| LogisVert, indicative amount | $2,688 |
Capacities: NEEP registry. At 8.3 °C, GENERAL's manual gives slightly different maximums: 29,000 BTU/h for the 24,000 and 37,500 for the 36,000. Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.
The 6 Altair 500 online
Price by quote.
GENERAL // Did you know
Three details about the Altair 500, from its documents
Did you know · The minimum
How far down can the Altair 500 9,000 throttle in heating?
Did you know · The two big ones
In deep cold, does the 36,000 heat more than the 30,000?
Did you know · The remote
Do all six Altair 500 sizes have the same remote?
LogisVert
From $0 to $2,688 depending on size
Under the LogisVert guide v1.10 (September 15, 2026): $0 for the 9,000 (under 12,000 BTU/h of nominal cooling), $435 for the 12,000 (ENERGY STAR, $50 per 1,000 BTU/h at −8 °C), then, cold climate at $120, $1,356 (18,000), $1,776 (24,000), $2,352 (30,000) and $2,688 (36,000), as indicative amounts.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about the Altair 500
From what size is it cold climate?
From 18,000 BTU. The 9,000 and the 12,000 are ENERGY STAR certified without the cold-climate mention; that is what moves the LogisVert amount from $50 to $120 per 1,000 BTU/h at −8 °C.
At −15 °C, what does each Altair 500 size give?
From 7,100 BTU/h (9,000) to 25,800 BTU/h (30,000 and 36,000), on the NEEP listings. That is the bottom of its published heating range; its submittals state it has no automatic low-temperature cut-out.
Is Wi-Fi included?
No: it needs an optional USB Wi-Fi adapter, for the AIRSTAGE Mobile app. A backlit wireless remote is included.
With six sizes, how do you know which one fits?
Through a visit: the room, its insulation and its windows set the capacity, and the line route can rule out a build. We recommend a size after seeing all that, not before.
How much LogisVert for an Altair 500?
From $0 (9,000) to $2,688 (36,000), as indicative amounts. Only Hydro-Québec confirms the assistance granted.
An Altair 500 at the right size, installed by AirGreen.
Three builds, three line-length limits: we look on site at the room, the wall and the route to the outdoor unit, and the size follows. The quote then carries its AHRI number and indicative LogisVert amount.
Sold and installed by AirGreen.
See the Altair 700 · See the Altair 300 · See the LPAS (R-410A)
Sources
Where the numbers come from
- GENERAL, Altair 500 (KPAS1) series page, airstagehvac.com, read November 5, 2026.
- GENERAL, design and technical manual "Wall Mounted Type", DR_AS237ES, November 13, 2024, p. 2, 4 and 6.
- GENERAL, 09, 12, 18, 24, 30 and 36KPAS1 submittals, version 20250409A.
- NEEP listings 392096, 392097, 388110, 388111, 389411 and 389412, checked November 5, 2026.
- ENERGY STAR, Canadian market, records 3554408, 3554409, 3627258, 3627259, 3629536 and 3621237, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.