GENERAL AIRSTAGE // LZAS · R-410A
LZAS: GENERAL R-410A wall heat pump from 9,000 to 15,000 BTU, function by function
3 sizes on R-410A, with the ASUG..LZBS indoor unit, the same as the LZAH's. Its manual describes seven functions, from the human sensor to the weekly timer; the tool shows what each one does and which ones a wired controller restricts.
R-32 at GENERAL
The Orion XLTH, on R-32, from 9,000 to 24,000 BTU
On R-32, GENERAL's series closest to the LZAS in size and efficiency is the Orion XLTH.
Orion XLTH AOUH09KZAH1
- Refrigerant
- R-32
- SEER2 (NEEP)
- 33.1
- Coldest point on the NEEP listing
- −26 °C
LZAS AOUG09LZAS1
- Refrigerant
- R-410A
- SEER2 (NEEP)
- 33.1
- Coldest point on the NEEP listing
- −21 °C
At 9,000, the same SEER2 on the NEEP listings, 33.1; the Orion XLTH listing goes down to −26 °C, the LZAS listing stops at −21 °C.
The tool // Function by function
Seven indoor-unit functions: what each one does, with or without a wired controller
Pick a function, then the control. GENERAL's manual says what the function does, and whether a wired wall controller restricts it.
Human sensor ASUG..LZBS
- What the manual says
- When nobody is in the room, the unit runs moderately to avoid wasting electricity; after about 20 minutes with nobody there, the temperature is adjusted.
- Name in the manual
- HUMAN SENSOR · section 7.2
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "HUMAN SENSOR" works as section 7.2 describes, and the manual does not restrict it with a wired controller either.
Human sensor ASUG..LZBS
- What the manual says
- When nobody is in the room, the unit runs moderately to avoid wasting electricity; after about 20 minutes with nobody there, the temperature is adjusted.
- Name in the manual
- HUMAN SENSOR · section 7.2
- With a 2-wire wired controller
- not on the restricted list
"HUMAN SENSOR" is not on the list of functions the manual restricts with a 2-wire wired controller (section 12.1).
Weekly timer ASUG..LZBS
- What the manual says
- Up to 4 settings for each day of the week.
- Name in the manual
- WEEKLY TIMER · section 6.1
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "WEEKLY TIMER" works as section 6.1 describes; adding a 2-wire wired controller is what would restrict it (section 12.1).
Weekly timer ASUG..LZBS
- What the manual says
- Up to 4 settings for each day of the week.
- Name in the manual
- WEEKLY TIMER · section 6.1
- With a 2-wire wired controller
- restricted
Restricted: the manual lists "WEEKLY TIMER" among the functions limited when a 2-wire wired controller is connected (section 12.1). If you set it anyway, the unit beeps and its indicators blink.
Powerful ASUG..LZBS
- What the manual says
- Maximum power and strong airflow to cool or warm the room quickly; the mode stops by itself 20 minutes after it starts.
- Name in the manual
- POWERFUL · section 8.1
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "POWERFUL" works as section 8.1 describes; adding a 2-wire wired controller is what would restrict it (section 12.1).
Powerful ASUG..LZBS
- What the manual says
- Maximum power and strong airflow to cool or warm the room quickly; the mode stops by itself 20 minutes after it starts.
- Name in the manual
- POWERFUL · section 8.1
- With a 2-wire wired controller
- restricted
Restricted: the manual lists "POWERFUL" among the functions limited when a 2-wire wired controller is connected (section 12.1). If you set it anyway, the unit beeps and its indicators blink.
Economy ASUG..LZBS
- What the manual says
- Saves more electricity than the other modes by moving the set temperature to a moderate setting.
- Name in the manual
- ECONOMY · section 7.1
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "ECONOMY" works as section 7.1 describes, and the manual does not restrict it with a wired controller either.
Economy ASUG..LZBS
- What the manual says
- Saves more electricity than the other modes by moving the set temperature to a moderate setting.
- Name in the manual
- ECONOMY · section 7.1
- With a 2-wire wired controller
- not on the restricted list
"ECONOMY" is not on the list of functions the manual restricts with a 2-wire wired controller (section 12.1).
Minimum heat ASUG..LZBS
- What the manual says
- Keeps the room at 10 °C (50 °F) so the temperature does not drop too low.
- Name in the manual
- MIN. HEAT · section 8.3
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "MIN. HEAT" works as section 8.3 describes; adding a 2-wire wired controller is what would restrict it (section 12.1).
Minimum heat ASUG..LZBS
- What the manual says
- Keeps the room at 10 °C (50 °F) so the temperature does not drop too low.
- Name in the manual
- MIN. HEAT · section 8.3
- With a 2-wire wired controller
- restricted
Restricted: the manual lists "MIN. HEAT" among the functions limited when a 2-wire wired controller is connected (section 12.1). If you set it anyway, the unit beeps and its indicators blink.
Outdoor-unit low noise ASUG..LZBS
- What the manual says
- The compressor runs slower and the outdoor unit fan turns slowly.
- Name in the manual
- OUTDOOR UNIT LOW NOISE · section 8.2
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "OUTDOOR UNIT LOW NOISE" works as section 8.2 describes; adding a 2-wire wired controller is what would restrict it (section 12.1).
Outdoor-unit low noise ASUG..LZBS
- What the manual says
- The compressor runs slower and the outdoor unit fan turns slowly.
- Name in the manual
- OUTDOOR UNIT LOW NOISE · section 8.2
- With a 2-wire wired controller
- restricted
Restricted: the manual lists "OUTDOOR UNIT LOW NOISE" among the functions limited when a 2-wire wired controller is connected (section 12.1). If you set it anyway, the unit beeps and its indicators blink.
Sleep ASUG..LZBS
- What the manual says
- A timer from 30 minutes to 9 hours; in cooling or dry mode the unit stops when the time is up, and in heating the set temperature changes gradually during the timer.
- Name in the manual
- SLEEP · section 6.4
- Wireless remote only
- as the manual describes it, with no wired controller
With the wireless remote alone, "SLEEP" works as section 6.4 describes, and the manual does not restrict it with a wired controller either.
Sleep ASUG..LZBS
- What the manual says
- A timer from 30 minutes to 9 hours; in cooling or dry mode the unit stops when the time is up, and in heating the set temperature changes gradually during the timer.
- Name in the manual
- SLEEP · section 6.4
- With a 2-wire wired controller
- not on the restricted list
"SLEEP" is not on the list of functions the manual restricts with a 2-wire wired controller (section 12.1).
GENERAL, ASUG09-15LZBS wall-mounted indoor unit operation manual, ref. 9387602210-02, sections 6 to 8 (functions) and 12.1 (2-wire wired controller), read November 5, 2026. The LZAH uses the same indoor unit. The wired controller is an option; the manual states that the wireless remote and the wired controller can be used together.
The three sizes
Each size at a glance
LZAS 9,000 BTU · AOUG09LZAS1
| Units | ASUG09LZBS / AOUG09LZAS1 |
|---|---|
| AHRI | 206597208 |
| NEEP listing | 438615 |
| ENERGY STAR Canada | 2417192 · cold climate |
| SEER2 · HSPF2 (IV) | 33.1 · 13.4 |
| At 8.3 °C, rated (min–max) | 9,000 BTU/h (3,100–22,000) |
| At −8.3 °C · at −15 °C, rated | 7,400 · 15,400 BTU/h |
| Coldest point on the listing | −21 °C: 14,000 BTU/h |
| Heating limit (NEEP point and our product pages) | −21 °C |
| Indoor sound, quiet speed (our product pages) | 23 dB(A) |
| LogisVert, indicative amount | $0 (under 12,000 BTU/h nominal) |
LZAS 12,000 BTU · AOUG12LZAS1
| Units | ASUG12LZBS / AOUG12LZAS1 |
|---|---|
| AHRI | 206597210 |
| NEEP listing | 438613 |
| ENERGY STAR Canada | 2409903 · cold climate |
| SEER2 · HSPF2 (IV) | 29.4 · 12.9 |
| At 8.3 °C, rated (min–max) | 12,000 BTU/h (3,100–22,100) |
| At −8.3 °C · at −15 °C, rated | 10,000 · 16,600 BTU/h |
| Coldest point on the listing | −21 °C: 15,000 BTU/h |
| Heating limit (NEEP point and our product pages) | −21 °C |
| Indoor sound, quiet speed (our product pages) | 23 dB(A) |
| LogisVert, indicative amount | $1,200 |
LZAS 15,000 BTU · AOUG15LZAS1
| Units | ASUG15LZBS / AOUG15LZAS1 |
|---|---|
| AHRI | 206597212 |
| NEEP listing | 438611 |
| ENERGY STAR Canada | 2417194 · cold climate |
| SEER2 · HSPF2 (IV) | 25.3 · 12.8 |
| At 8.3 °C, rated (min–max) | 14,500 BTU/h (3,100–23,900) |
| At −8.3 °C · at −15 °C, rated | 11,200 · 17,500 BTU/h |
| Coldest point on the listing | −21 °C: 18,600 BTU/h |
| Heating limit (NEEP point and our product pages) | −21 °C |
| Indoor sound, quiet speed (our product pages) | 26 dB(A) |
| LogisVert, indicative amount | $1,344 |
Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.
The 3 LZAS online
Price by quote.
GENERAL // Did you know
Three details about the LZAS, from GENERAL's own documents
Did you know · The name
Under what name does GENERAL sell the AOUG..LZAS1 outdoor unit with our indoor unit?
Did you know · The defrost
How long can a defrost cycle last?
Did you know · The filters
How often does the manual ask for the ASUG..LZBS filters to be looked after?
LogisVert
The same amount as the LZAH, size for size
ENERGY STAR Canada lists the LZAS with the cold climate mark (records 2417192, 2409903 and 2417194). At −8.3 °C its rated heating is that of the same-size LZAH, 10,000 BTU/h at 12,000 and 11,200 at 15,000; so are its indicative amounts, at $120 per 1,000 BTU/h under the LogisVert guide v1.10 (September 15, 2026): $1,200 and $1,344. The 9,000, under 12,000 BTU/h of nominal cooling, stays at $0.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about the LZAS
LZAS or LZAH?
The LZAH adds a base pan heater and a published −26 °C heating limit; the LZAH page compares the two, temperature by temperature. If your winter goes below −21 °C, look at it; we decide together on site.
Is Wi-Fi built in?
No: with the ASUG..LZBS indoor unit on our product pages, Wi-Fi goes through the UTY-TFSXH4 adapter, an option according to GENERAL. The app then works through that module.
What happens below −21 °C?
No heating value is published below that point: the LZAS NEEP listing stops at −21 °C, and GENERAL's LZAS1 series page states −5 °F (−21 °C), with no table per model. If the house keeps other heating, such as baseboard heaters, it takes over, and we look at this with you during the visit.
Between the LZAS 12,000 and the 15,000, which one?
Whichever the room calls for, and we only know after seeing it: its insulation, its windows, where the outdoor unit goes. This page is for comparing the two, not for choosing between them.
Is it quiet?
At quiet speed, our product pages give 23 dB(A) in the room at 9,000 and 12,000, and 26 dB(A) at 15,000. On the Québec.ca scale, 20 dB(A) is "whispers heard a metre away" and 30 dB(A) "a low-voice conversation".
How much LogisVert for an LZAS?
$1,200 for the 12,000 and $1,344 for the 15,000, as indicative amounts; $0 for the 9,000. Only Hydro-Québec confirms the assistance granted.
An LZAS and the control that suits you, installed by AirGreen.
During the visit we look at the room, where the outdoor unit goes and where a wired wall controller could sit; we also compare the LZAS and the LZAH with you. The quote then gives the AHRI number and indicative LogisVert amount of the model chosen.
Sold and installed by AirGreen.
See the Orion XLTH (R-32) · See the LZAH (−26 °C) · Compare the 13 wall series
Sources
Where the numbers come from
- GENERAL, ASUG09-15LZBS wall-mounted indoor unit operation manual, ref. 9387602210-02, sections 6 to 8, 10, 11 and 12.1, read November 5, 2026.
- GENERAL, LZAS1 and LZBS1 series pages (US site archive), read November 5, 2026.
- NEEP listings 438611, 438613 and 438615 (LZAS), 438610, 438612 and 438614 (LZAH), checked November 5, 2026.
- ENERGY STAR, Canadian market, records 2417192, 2409903 and 2417194, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.
Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.