AirGreenGENERAL

AirGreen × GENERAL AIRSTAGE

Sold and installed by AirGreen.

Montreal, Laval, Longueuil, the North Shore and the South Shore.

GENERAL AIRSTAGE // LZAH · R-410A

LZAH: the GENERAL R-410A wall heat pump published down to −26 °C, at 9,000, 12,000 and 15,000 BTU

3 sizes on R-410A, with the same indoor unit as the LZAS, a base pan heater and a heating range published down to −26 °C. It is the deep-cold version of the LZ pair.

3listings online
−26 °Cheating limit published by GENERAL; −21 °C for the LZAS, NEEP point and our product pages
33.1SEER2, at 9,000 BTU
39 kgthe outdoor unit at 9,000 and 12,000, 40 kg at 15,000, according to GENERAL
$1,344highest LogisVert, at 15,000 BTUIndicative amount. Only Hydro-Québec confirms the assistance granted.

R-32 at GENERAL

The Orion XLTH, the R-32 series that also reaches −26 °C

On R-32, GENERAL's series closest to the LZAH in size and cold is the Orion XLTH, from 9,000 to 24,000 BTU.

Orion XLTH AOUH12KZAH1

Refrigerant
R-32
Published heating limit
−26 °C
At −26 °C, maximum (NEEP)
12,200 BTU/h

LZAH AOUG12LZAH1

Refrigerant
R-410A
Published heating limit
−26 °C
At −26 °C, maximum (NEEP)
11,800 BTU/h

At 12,000, GENERAL publishes both down to −26 °C; at that point, on the NEEP listings, the Orion XLTH gives at most 12,200 BTU/h, the LZAH 11,800 BTU/h.

See the Orion XLTH (R-32)

The tool // The extra cold

Pick the size, the temperature and the comparison: the R-32 Orion XLTH, or the LZAS

The Orion XLTH is GENERAL's R-32 series that also goes down to −26 °C, from 9,000 to 15,000 BTU like the LZAH. The LZAS shares the LZAH's ASUG..LZBS indoor unit: down to −15 °C their NEEP listings give the same heat, and at −26 °C only the LZAH is left.

Size, BTU
Outdoors
Compare with

Orion XLTH AOUH12KZAH1 · R-32

Maximum heating
12,200 BTU/h
Rated heating
not published at this point
COP at maximum
1.81

LZAH AOUG12LZAH1 · R-410A

Maximum heating
11,800 BTU/h
Rated heating
not published at this point
COP at maximum
1.55

At −26 °C, at maximum, the Orion XLTH gives 400 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 1.81 and the LZAH at 1.55.

NEEP listings 392121, 392122 and 392123 (Orion XLTH), 438610, 438612 and 438614 (LZAH) and 438611, 438613 and 438615 (LZAS), modified August 24, 2026 and checked November 5, 2026, at 21 °C indoors. The LZAH's coldest point on the listing is −26 °C, the LZAS's −21 °C. The LZAH's −26 °C is also its limit published by GENERAL (09, 12 and 15LZASH1 submittals); for the LZAS, −21 °C is a NEEP point and our product pages' value, and GENERAL's LZAS1 series page states −5 °F (−21 °C), with no table per model.

The three sizes

Each size at a glance

LZAH 9,000 BTU · AOUG09LZAH1

UnitsASUG09LZBS / AOUG09LZAH1
AHRI206597209
NEEP listing438614
ENERGY STAR Canada2417193 · cold climate
SEER2 · HSPF2 (IV)33.1 · 13.3
At 8.3 °C, rated (min–max)9,000 BTU/h (3,100–22,000)
At −8.3 °C · at −15 °C, rated7,400 · 15,400 BTU/h
Coldest point on the listing−26 °C: 11,100 BTU/h
Heating limit published by GENERAL−26 °C
Indoor sound, quiet speed (our product pages)23 dB(A)
LogisVert, indicative amount$0 (under 12,000 BTU/h nominal)

LZAH 12,000 BTU · AOUG12LZAH1

UnitsASUG12LZBS / AOUG12LZAH1
AHRI206597211
NEEP listing438612
ENERGY STAR Canada2409902 · cold climate
SEER2 · HSPF2 (IV)29.4 · 12.7
At 8.3 °C, rated (min–max)12,000 BTU/h (3,100–22,100)
At −8.3 °C · at −15 °C, rated10,000 · 16,600 BTU/h
Coldest point on the listing−26 °C: 11,800 BTU/h
Heating limit published by GENERAL−26 °C
Indoor sound, quiet speed (our product pages)23 dB(A)
LogisVert, indicative amount$1,200

LZAH 15,000 BTU · AOUG15LZAH1

UnitsASUG15LZBS / AOUG15LZAH1
AHRI206597213
NEEP listing438610
ENERGY STAR Canada2417195 · cold climate
SEER2 · HSPF2 (IV)25.3 · 12.7
At 8.3 °C, rated (min–max)14,500 BTU/h (3,100–23,900)
At −8.3 °C · at −15 °C, rated11,200 · 17,500 BTU/h
Coldest point on the listing−26 °C: 16,300 BTU/h
Heating limit published by GENERAL−26 °C
Indoor sound, quiet speed (our product pages)26 dB(A)
LogisVert, indicative amount$1,344

Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.

The 3 LZAH online

Price by quote.

What the submittals say

The LZAH in GENERAL's figures

−10 to 46 °Cpublished cooling range; in heating, −26 to 24 °C.
3 to 20 mof line, 15 m pre-charged, 15 m of height difference at most.
632 × 799 × 290 mmthe AOUG..LZAH1 outdoor unit, the same for all three sizes.
23 dB(A)indoors, at quiet speed, at 9,000 and 12,000; 26 dB(A) at 15,000. These submittals describe the ASUG..LZAS indoor unit, not the ASUG..LZBS on our product pages.

Source: GENERAL, 09, 12 and 15LZASH1 submittals, effective April 17, 2020 (AOUG..LZAH1 outdoor unit).

GENERAL // Did you know

Three details about the LZAH, from GENERAL's own documents

Did you know · The pan

Between the LZAS and the LZAH, which has a factory base pan heater?

Did you know · Outdoors

What sound level does GENERAL give for the LZAH outdoor unit?

Did you know · The secret

What does GENERAL credit for this family's deep-cold heating?

LogisVert

$0, $1,200 or $1,344

The LZAH is listed with ENERGY STAR Canada with the cold climate mark at 9,000, 12,000 and 15,000 (records 2417193, 2409902 and 2417195). At $120 per 1,000 BTU/h of heating at −8 °C under the LogisVert guide v1.10 (September 15, 2026), the 12,000 and its 10,000 BTU/h rated at −8.3 °C come to $1,200, the 15,000 and its 11,200 BTU/h to $1,344, as indicative amounts. The 9,000 is left out: its outdoor unit does not reach the 12,000 BTU/h of nominal cooling the guide asks for.

These are indicative amounts. Only Hydro-Québec confirms the assistance granted.

The LogisVert rules, explained by AirGreen

Questions

What people ask us about the LZAH

Orion XLTH or LZAH?

Both are published down to −26 °C; the Orion XLTH is on R-32 and goes up to 24,000 BTU. The Orion XLTH page compares them size by size, from 8.3 °C down to −26 °C.

LZAH or LZAS?

Same indoor unit, same output down to −15 °C. The LZAH adds a base pan heater and a heating range published by GENERAL down to −26 °C; for the LZAS, −21 °C is a NEEP point and our product pages' value. The LZAS has the same COP at 8.3 °C and a slightly higher one at −8.3 and −15 °C.

The LZAH 9,000 or the 12,000: who decides?

The room, which we come and see before recommending anything: its insulation, its windows, its exposure. One gap worth keeping in mind: LogisVert does not count the 9,000, and counts an indicative $1,200 for the 12,000. Only Hydro-Québec confirms the assistance granted.

How much line between the two units?

From 3 to 20 m according to GENERAL's submittals, 15 m of it already charged with refrigerant, and at most 15 m of height difference. We measure the run during the on-site assessment.

How much LogisVert for an LZAH?

$0 for the 9,000, $1,200 for the 12,000 and $1,344 for the 15,000, as indicative amounts. Only Hydro-Québec confirms the assistance granted.

AirGreenGENERAL

The LZAH, the deep-cold version of the LZ pair, installed by AirGreen.

During the visit we look with you at whether your winter calls for the LZAH's −26 °C point or whether the LZAS will do, and where the outdoor unit can go, within 20 m of line. The AHRI number and indicative LogisVert amount of the model chosen then appear on the quote.

Sold and installed by AirGreen.

See the Orion XLTH (R-32, −26 °C) · See the LZAS · Compare the 13 wall series

Sources

Where the numbers come from

  1. GENERAL, 09LZASH1, 12LZASH1 and 15LZASH1 submittals, effective April 17, 2020.
  2. GENERAL, press release on the new LZ and LM wall units, February 3, 2020.
  3. GENERAL, XLTH series page (US site archive), read November 5, 2026.
  4. NEEP listings 438610, 438612 and 438614 (LZAH), 438611, 438613 and 438615 (LZAS), checked November 5, 2026.
  5. ENERGY STAR, Canadian market, records 2417193, 2409902 and 2417195, checked November 5, 2026.
  6. Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
  7. airgreen.ca product pages, read November 5, 2026.

Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.