Added to comparison
-
Added to comparison
-
Added to comparison
AirGreen × GENERAL AIRSTAGE
Sold and installed by AirGreen.
Montreal, Laval, Longueuil, the North Shore and the South Shore.
GENERAL AIRSTAGE // LZAH · R-410A
LZAH: the GENERAL R-410A wall heat pump published down to −26 °C, at 9,000, 12,000 and 15,000 BTU
3 sizes on R-410A, with the same indoor unit as the LZAS, a base pan heater and a heating range published down to −26 °C. It is the deep-cold version of the LZ pair.
R-32 at GENERAL
The Orion XLTH, the R-32 series that also reaches −26 °C
On R-32, GENERAL's series closest to the LZAH in size and cold is the Orion XLTH, from 9,000 to 24,000 BTU.
Orion XLTH AOUH12KZAH1
- Refrigerant
- R-32
- Published heating limit
- −26 °C
- At −26 °C, maximum (NEEP)
- 12,200 BTU/h
LZAH AOUG12LZAH1
- Refrigerant
- R-410A
- Published heating limit
- −26 °C
- At −26 °C, maximum (NEEP)
- 11,800 BTU/h
At 12,000, GENERAL publishes both down to −26 °C; at that point, on the NEEP listings, the Orion XLTH gives at most 12,200 BTU/h, the LZAH 11,800 BTU/h.
The tool // The extra cold
Pick the size, the temperature and the comparison: the R-32 Orion XLTH, or the LZAS
The Orion XLTH is GENERAL's R-32 series that also goes down to −26 °C, from 9,000 to 15,000 BTU like the LZAH. The LZAS shares the LZAH's ASUG..LZBS indoor unit: down to −15 °C their NEEP listings give the same heat, and at −26 °C only the LZAH is left.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 23,000 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.08
LZAH AOUG09LZAH1 · R-410A
- Maximum heating
- 22,000 BTU/h
- Rated heating
- 9,000 BTU/h
- COP at maximum
- 3.34
At 8.3 °C, at maximum, the Orion XLTH gives 1,000 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 3.08 and the LZAH at 3.34.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 17,500 BTU/h
- Rated heating
- 7,500 BTU/h
- COP at maximum
- 2.49
LZAH AOUG09LZAH1 · R-410A
- Maximum heating
- 16,000 BTU/h
- Rated heating
- 7,400 BTU/h
- COP at maximum
- 2.12
At −8.3 °C, at maximum, the Orion XLTH gives 1,500 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 2.49 and the LZAH at 2.12.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 15,400 BTU/h
- Rated heating
- 15,400 BTU/h
- COP at maximum
- 2.26
LZAH AOUG09LZAH1 · R-410A
- Maximum heating
- 15,400 BTU/h
- Rated heating
- 15,400 BTU/h
- COP at maximum
- 2.01
At −15 °C, the same maximum heating on the NEEP listings: 15,400 BTU/h. At maximum, the Orion XLTH runs at a COP of 2.26 and the LZAH at 2.01.
Orion XLTH AOUH09KZAH1 · R-32
- Maximum heating
- 11,400 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.70
LZAH AOUG09LZAH1 · R-410A
- Maximum heating
- 11,100 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.46
At −26 °C, at maximum, the Orion XLTH gives 300 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 1.70 and the LZAH at 1.46.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 23,600 BTU/h
- Rated heating
- 16,000 BTU/h
- COP at maximum
- 3.07
LZAH AOUG12LZAH1 · R-410A
- Maximum heating
- 22,100 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.34
At 8.3 °C, at maximum, the Orion XLTH gives 1,500 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 3.07 and the LZAH at 3.34.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 18,700 BTU/h
- Rated heating
- 10,000 BTU/h
- COP at maximum
- 2.44
LZAH AOUG12LZAH1 · R-410A
- Maximum heating
- 17,500 BTU/h
- Rated heating
- 10,000 BTU/h
- COP at maximum
- 2.32
At −8.3 °C, at maximum, the Orion XLTH gives 1,200 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 2.44 and the LZAH at 2.32.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 16,600 BTU/h
- Rated heating
- 16,600 BTU/h
- COP at maximum
- 2.16
LZAH AOUG12LZAH1 · R-410A
- Maximum heating
- 16,600 BTU/h
- Rated heating
- 16,600 BTU/h
- COP at maximum
- 2.16
At −15 °C, the same maximum heating on the NEEP listings: 16,600 BTU/h. At maximum, the Orion XLTH runs at a COP of 2.16 and the LZAH at 2.16.
Orion XLTH AOUH12KZAH1 · R-32
- Maximum heating
- 12,200 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.81
LZAH AOUG12LZAH1 · R-410A
- Maximum heating
- 11,800 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.55
At −26 °C, at maximum, the Orion XLTH gives 400 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 1.81 and the LZAH at 1.55.
Orion XLTH AOUH15KZAH1 · R-32
- Maximum heating
- 25,000 BTU/h
- Rated heating
- 18,000 BTU/h
- COP at maximum
- 3.26
LZAH AOUG15LZAH1 · R-410A
- Maximum heating
- 23,900 BTU/h
- Rated heating
- 14,500 BTU/h
- COP at maximum
- 3.20
At 8.3 °C, at maximum, the Orion XLTH gives 1,100 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 3.26 and the LZAH at 3.20.
Orion XLTH AOUH15KZAH1 · R-32
- Maximum heating
- 22,000 BTU/h
- Rated heating
- 11,400 BTU/h
- COP at maximum
- 2.35
LZAH AOUG15LZAH1 · R-410A
- Maximum heating
- 21,500 BTU/h
- Rated heating
- 11,200 BTU/h
- COP at maximum
- 2.30
At −8.3 °C, at maximum, the Orion XLTH gives 500 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 2.35 and the LZAH at 2.30.
Orion XLTH AOUH15KZAH1 · R-32
- Maximum heating
- 21,000 BTU/h
- Rated heating
- 21,000 BTU/h
- COP at maximum
- 2.10
LZAH AOUG15LZAH1 · R-410A
- Maximum heating
- 21,000 BTU/h
- Rated heating
- 17,500 BTU/h
- COP at maximum
- 2.12
At −15 °C, the same maximum heating on the NEEP listings: 21,000 BTU/h. At maximum, the Orion XLTH runs at a COP of 2.10 and the LZAH at 2.12.
Orion XLTH AOUH15KZAH1 · R-32
- Maximum heating
- 16,400 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.92
LZAH AOUG15LZAH1 · R-410A
- Maximum heating
- 16,300 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.66
At −26 °C, at maximum, the Orion XLTH gives 100 BTU/h more than the LZAH. At maximum, the Orion XLTH runs at a COP of 1.92 and the LZAH at 1.66.
LZAH AOUG09LZAH1
- Maximum heating
- 22,000 BTU/h
- Rated heating
- 9,000 BTU/h
- COP at maximum
- 3.34
LZAS AOUG09LZAS1
- Maximum heating
- 22,000 BTU/h
- Rated heating
- 9,000 BTU/h
- COP at maximum
- 3.34
At 8.3 °C, both give the same maximum heating, 22,000 BTU/h on the NEEP listings, at the same COP, 3.34.
LZAH AOUG09LZAH1
- Maximum heating
- 16,000 BTU/h
- Rated heating
- 7,400 BTU/h
- COP at maximum
- 2.12
LZAS AOUG09LZAS1
- Maximum heating
- 16,000 BTU/h
- Rated heating
- 7,400 BTU/h
- COP at maximum
- 2.28
At −8.3 °C, both give the same maximum heating, 16,000 BTU/h on the NEEP listings; COP: 2.28 for the LZAS, 2.12 for the LZAH.
LZAH AOUG09LZAH1
- Maximum heating
- 15,400 BTU/h
- Rated heating
- 15,400 BTU/h
- COP at maximum
- 2.01
LZAS AOUG09LZAS1
- Maximum heating
- 15,400 BTU/h
- Rated heating
- 15,400 BTU/h
- COP at maximum
- 2.15
At −15 °C, both give the same maximum heating, 15,400 BTU/h on the NEEP listings; COP: 2.15 for the LZAS, 2.01 for the LZAH.
LZAH AOUG09LZAH1
- Maximum heating
- 11,100 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.46
LZAS AOUG09LZAS1
- At −26 °C
- not published
- Its limit (NEEP point and our product pages)
- −21 °C
- Maximum at −21 °C
- 14,000 BTU/h
At −26 °C only the LZAH has a published value: 11,100 BTU/h, COP 1.46. The NEEP listing of the same-size LZAS stops at −21 °C, where it gives at most 14,000 BTU/h.
LZAH AOUG12LZAH1
- Maximum heating
- 22,100 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.34
LZAS AOUG12LZAS1
- Maximum heating
- 22,100 BTU/h
- Rated heating
- 12,000 BTU/h
- COP at maximum
- 3.34
At 8.3 °C, both give the same maximum heating, 22,100 BTU/h on the NEEP listings, at the same COP, 3.34.
LZAH AOUG12LZAH1
- Maximum heating
- 17,500 BTU/h
- Rated heating
- 10,000 BTU/h
- COP at maximum
- 2.32
LZAS AOUG12LZAS1
- Maximum heating
- 17,500 BTU/h
- Rated heating
- 10,000 BTU/h
- COP at maximum
- 2.49
At −8.3 °C, both give the same maximum heating, 17,500 BTU/h on the NEEP listings; COP: 2.49 for the LZAS, 2.32 for the LZAH.
LZAH AOUG12LZAH1
- Maximum heating
- 16,600 BTU/h
- Rated heating
- 16,600 BTU/h
- COP at maximum
- 2.16
LZAS AOUG12LZAS1
- Maximum heating
- 16,600 BTU/h
- Rated heating
- 16,600 BTU/h
- COP at maximum
- 2.32
At −15 °C, both give the same maximum heating, 16,600 BTU/h on the NEEP listings; COP: 2.32 for the LZAS, 2.16 for the LZAH.
LZAH AOUG12LZAH1
- Maximum heating
- 11,800 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.55
LZAS AOUG12LZAS1
- At −26 °C
- not published
- Its limit (NEEP point and our product pages)
- −21 °C
- Maximum at −21 °C
- 15,000 BTU/h
At −26 °C only the LZAH has a published value: 11,800 BTU/h, COP 1.55. The NEEP listing of the same-size LZAS stops at −21 °C, where it gives at most 15,000 BTU/h.
LZAH AOUG15LZAH1
- Maximum heating
- 23,900 BTU/h
- Rated heating
- 14,500 BTU/h
- COP at maximum
- 3.20
LZAS AOUG15LZAS1
- Maximum heating
- 23,900 BTU/h
- Rated heating
- 14,500 BTU/h
- COP at maximum
- 3.20
At 8.3 °C, both give the same maximum heating, 23,900 BTU/h on the NEEP listings, at the same COP, 3.20.
LZAH AOUG15LZAH1
- Maximum heating
- 21,500 BTU/h
- Rated heating
- 11,200 BTU/h
- COP at maximum
- 2.30
LZAS AOUG15LZAS1
- Maximum heating
- 21,500 BTU/h
- Rated heating
- 11,200 BTU/h
- COP at maximum
- 2.43
At −8.3 °C, both give the same maximum heating, 21,500 BTU/h on the NEEP listings; COP: 2.43 for the LZAS, 2.30 for the LZAH.
LZAH AOUG15LZAH1
- Maximum heating
- 21,000 BTU/h
- Rated heating
- 17,500 BTU/h
- COP at maximum
- 2.12
LZAS AOUG15LZAS1
- Maximum heating
- 21,000 BTU/h
- Rated heating
- 17,500 BTU/h
- COP at maximum
- 2.24
At −15 °C, both give the same maximum heating, 21,000 BTU/h on the NEEP listings; COP: 2.24 for the LZAS, 2.12 for the LZAH.
LZAH AOUG15LZAH1
- Maximum heating
- 16,300 BTU/h
- Rated heating
- not published at this point
- COP at maximum
- 1.66
LZAS AOUG15LZAS1
- At −26 °C
- not published
- Its limit (NEEP point and our product pages)
- −21 °C
- Maximum at −21 °C
- 18,600 BTU/h
At −26 °C only the LZAH has a published value: 16,300 BTU/h, COP 1.66. The NEEP listing of the same-size LZAS stops at −21 °C, where it gives at most 18,600 BTU/h.
NEEP listings 392121, 392122 and 392123 (Orion XLTH), 438610, 438612 and 438614 (LZAH) and 438611, 438613 and 438615 (LZAS), modified August 24, 2026 and checked November 5, 2026, at 21 °C indoors. The LZAH's coldest point on the listing is −26 °C, the LZAS's −21 °C. The LZAH's −26 °C is also its limit published by GENERAL (09, 12 and 15LZASH1 submittals); for the LZAS, −21 °C is a NEEP point and our product pages' value, and GENERAL's LZAS1 series page states −5 °F (−21 °C), with no table per model.
The three sizes
Each size at a glance
LZAH 9,000 BTU · AOUG09LZAH1
| Units | ASUG09LZBS / AOUG09LZAH1 |
|---|---|
| AHRI | 206597209 |
| NEEP listing | 438614 |
| ENERGY STAR Canada | 2417193 · cold climate |
| SEER2 · HSPF2 (IV) | 33.1 · 13.3 |
| At 8.3 °C, rated (min–max) | 9,000 BTU/h (3,100–22,000) |
| At −8.3 °C · at −15 °C, rated | 7,400 · 15,400 BTU/h |
| Coldest point on the listing | −26 °C: 11,100 BTU/h |
| Heating limit published by GENERAL | −26 °C |
| Indoor sound, quiet speed (our product pages) | 23 dB(A) |
| LogisVert, indicative amount | $0 (under 12,000 BTU/h nominal) |
LZAH 12,000 BTU · AOUG12LZAH1
| Units | ASUG12LZBS / AOUG12LZAH1 |
|---|---|
| AHRI | 206597211 |
| NEEP listing | 438612 |
| ENERGY STAR Canada | 2409902 · cold climate |
| SEER2 · HSPF2 (IV) | 29.4 · 12.7 |
| At 8.3 °C, rated (min–max) | 12,000 BTU/h (3,100–22,100) |
| At −8.3 °C · at −15 °C, rated | 10,000 · 16,600 BTU/h |
| Coldest point on the listing | −26 °C: 11,800 BTU/h |
| Heating limit published by GENERAL | −26 °C |
| Indoor sound, quiet speed (our product pages) | 23 dB(A) |
| LogisVert, indicative amount | $1,200 |
LZAH 15,000 BTU · AOUG15LZAH1
| Units | ASUG15LZBS / AOUG15LZAH1 |
|---|---|
| AHRI | 206597213 |
| NEEP listing | 438610 |
| ENERGY STAR Canada | 2417195 · cold climate |
| SEER2 · HSPF2 (IV) | 25.3 · 12.7 |
| At 8.3 °C, rated (min–max) | 14,500 BTU/h (3,100–23,900) |
| At −8.3 °C · at −15 °C, rated | 11,200 · 17,500 BTU/h |
| Coldest point on the listing | −26 °C: 16,300 BTU/h |
| Heating limit published by GENERAL | −26 °C |
| Indoor sound, quiet speed (our product pages) | 26 dB(A) |
| LogisVert, indicative amount | $1,344 |
Indicative LogisVert amounts. Only Hydro-Québec confirms the assistance granted.
The 3 LZAH online
Price by quote.
What the submittals say
The LZAH in GENERAL's figures
Source: GENERAL, 09, 12 and 15LZASH1 submittals, effective April 17, 2020 (AOUG..LZAH1 outdoor unit).
GENERAL // Did you know
Three details about the LZAH, from GENERAL's own documents
Did you know · The pan
Between the LZAS and the LZAH, which has a factory base pan heater?
Did you know · Outdoors
What sound level does GENERAL give for the LZAH outdoor unit?
Did you know · The secret
What does GENERAL credit for this family's deep-cold heating?
LogisVert
$0, $1,200 or $1,344
The LZAH is listed with ENERGY STAR Canada with the cold climate mark at 9,000, 12,000 and 15,000 (records 2417193, 2409902 and 2417195). At $120 per 1,000 BTU/h of heating at −8 °C under the LogisVert guide v1.10 (September 15, 2026), the 12,000 and its 10,000 BTU/h rated at −8.3 °C come to $1,200, the 15,000 and its 11,200 BTU/h to $1,344, as indicative amounts. The 9,000 is left out: its outdoor unit does not reach the 12,000 BTU/h of nominal cooling the guide asks for.
These are indicative amounts. Only Hydro-Québec confirms the assistance granted.
Questions
What people ask us about the LZAH
Orion XLTH or LZAH?
Both are published down to −26 °C; the Orion XLTH is on R-32 and goes up to 24,000 BTU. The Orion XLTH page compares them size by size, from 8.3 °C down to −26 °C.
LZAH or LZAS?
Same indoor unit, same output down to −15 °C. The LZAH adds a base pan heater and a heating range published by GENERAL down to −26 °C; for the LZAS, −21 °C is a NEEP point and our product pages' value. The LZAS has the same COP at 8.3 °C and a slightly higher one at −8.3 and −15 °C.
The LZAH 9,000 or the 12,000: who decides?
The room, which we come and see before recommending anything: its insulation, its windows, its exposure. One gap worth keeping in mind: LogisVert does not count the 9,000, and counts an indicative $1,200 for the 12,000. Only Hydro-Québec confirms the assistance granted.
How much line between the two units?
From 3 to 20 m according to GENERAL's submittals, 15 m of it already charged with refrigerant, and at most 15 m of height difference. We measure the run during the on-site assessment.
How much LogisVert for an LZAH?
$0 for the 9,000, $1,200 for the 12,000 and $1,344 for the 15,000, as indicative amounts. Only Hydro-Québec confirms the assistance granted.
The LZAH, the deep-cold version of the LZ pair, installed by AirGreen.
During the visit we look with you at whether your winter calls for the LZAH's −26 °C point or whether the LZAS will do, and where the outdoor unit can go, within 20 m of line. The AHRI number and indicative LogisVert amount of the model chosen then appear on the quote.
Sold and installed by AirGreen.
See the Orion XLTH (R-32, −26 °C) · See the LZAS · Compare the 13 wall series
Sources
Where the numbers come from
- GENERAL, 09LZASH1, 12LZASH1 and 15LZASH1 submittals, effective April 17, 2020.
- GENERAL, press release on the new LZ and LM wall units, February 3, 2020.
- GENERAL, XLTH series page (US site archive), read November 5, 2026.
- NEEP listings 438610, 438612 and 438614 (LZAH), 438611, 438613 and 438615 (LZAS), checked November 5, 2026.
- ENERGY STAR, Canadian market, records 2417193, 2409902 and 2417195, checked November 5, 2026.
- Hydro-Québec, LogisVert participation guide, residential customers, version 1.10, September 15, 2026, p. 14-15.
- airgreen.ca product pages, read November 5, 2026.
Page updated November 5, 2026. Indicative LogisVert amounts: only Hydro-Québec confirms the assistance granted. Price by quote.