DETTSON Suprême Avantage SUP18-A240V12 Electric Furnace | 18 kW - 240V

In stock

The Dettson Suprême Avantage SUP18-A240V12: an 18 kW electric furnace with an ECM motor, well suited to serve as backup for a central heat pump.

Model numberSUP18-A240V12

18 kWat 240 V (13.5 kW at 208 V)
65 °Ftemperature rise at 240 V
3 tonsmax. coil (supply or return)
240/208 V · 2 wires1/2 HP ECM motorMotor covered 5 years
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP18-A240V12
ManufacturerDettson
SeriesSuprême Avantage (ECM)
Output18 kW at 240 V
Power supply240/208 V, 1 ph, 60 Hz
Ampacity94.7 A at 240 V
Max. cooling3 tons

An 18 kW ECM furnace to back up your central heat pump

The role of the SUP18-A240V12

A central heat pump heats the house for most of the winter, but it needs a backup heat source. The Dettson Suprême Avantage SUP18-A240V12 plays that role. The heat-pump coil goes on its supply or return side, up to 3 tons, and its electric elements take over when the thermostat calls for them.

One point to know: Dettson requires non-simultaneous operation. The elements and the heat pump never heat at the same time; the thermostat chooses one source or the other. We set up the system accordingly.

What you get

The furnace delivers 18 kW at 240 V (13.5 kW at 208 V), with a first stage of 9 kW. Its 1/2 HP ECM motor lets the airflow be set separately for heating and for cooling, which helps match the furnace to the coil. Dettson publishes a 65 °F temperature rise at 240 V and covers the ECM motor for 5 years, on top of parts for 5 years in residential use. Labour is not covered by the manufacturer.

The controls stay simple: continuous-fan switch, low/high power switch, heat-demand indicator light and front-mounted breakers.

In a home in the region

This model suits ducted homes whose heating needs come to 18 kW, whether in Longueuil, Laval or a Montreal neighbourhood. The electrical side can be planned ahead: Dettson publishes a 94.7 A ampacity and calls for a 100 A maximum breaker at 240 V. The furnace is wired on two wires, or on three wires with accessories.

As for location, the Suprême is multi-position: upflow, downflow with the DFB-SUP base depending on the floor, horizontal or suspended, at 36 1/2 in high and 22 in deep. It is approved for zero clearance and for copper or aluminum wiring.

What AirGreen does

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work lets us handle every step:

  • the free on-site estimate and the written quote;
  • setting the furnace and wiring it;
  • integrating the coil and connecting the ducts;
  • programming the thermostat to respect non-simultaneous operation;
  • setting the ECM airflow and commissioning.

We also work on the North Shore and the South Shore.

Let’s talk about your project

Ask for a free estimate for your furnace, alone or with a heat pump: you receive a detailed written quote. Financing can make the project easier.

01 · What it is for

Backup heat for a central heat pump

Paired with a heat-pump coil of up to 3 tons, the SUP18-A240V12 becomes the home’s backup heat source. Its ECM motor adjusts the airflow separately for heating and for cooling.

  • Central heat-pump projects that keep or install an electric furnace as backup
  • Adding central air conditioning to existing ductwork
  • Replacing an 18 kW electric furnace with an ECM-motor model
  • Basement, horizontal or suspended installations
Adjustable airflowThe 1/2 HP ECM motor is set for heating and for cooling.
Published electrical data94.7 A ampacity and 100 A maximum breaker at 240 V: the circuit can be planned at the quote stage.
Dettson warrantyParts for 5 years in residential use and ECM motor for 5 years.
Compatible with
DFB-SUP
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Avantage, ECM motor
TypeElectric furnace with elements, multi-position
Output18 kW at 240 V · 13.5 kW at 208 V
First-stage output9 kW at 240 V · 6.8 kW at 208 V
Heating output at 208 V46,130 BTU/h
Power supply240/208 V, 1 ph, 60 Hz, 2 wires (3 wires possible with accessories)
Element current75.8 / 65.7 A (240 / 208 V)
Motor current2.3 / 2.7 A (240 / 208 V)
Total current78.1 / 68.4 A (240 / 208 V)
Ampacity94.7 / 83.2 A (240 / 208 V)
Max. breaker100 / 90 A (240 / 208 V)
MotorECM, 1/2 HP
Blower wheel12 x 8
AirflowAdjustable for heating and for cooling
Temperature rise65 °F (240 V)
Max. cooling3 tons (coil on supply or return)
PositionsUpflow (factory), downflow (DFB-SUP base), horizontal left or right, suspended
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wiring
Manufacturer warrantyParts: 5 years (residential), 1 year (commercial); ECM motor: 5 years; labour not covered
Model numberSUP18-A240V12
03 · Before installing

What to know before installing

  • Sold alone, an electric furnace is not a heat pump: it does not qualify for the LogisVert grant.
  • With a heat pump, Dettson requires non-simultaneous operation of the elements and the heat pump: the thermostat must manage it.
  • Dedicated circuit: 100 A maximum breaker at 240 V (90 A at 208 V) and 94.7 A ampacity at 240 V.
  • The air-conditioning or heat-pump coil is not included; it goes on the supply or return side.
  • Standard 2-wire connection; a 3-wire connection (120–208/240 V) requires accessories.
  • In downflow, the DFB-SUP base may be required depending on the type of floor.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

Can it serve as backup for a central heat pump?

Yes. The heat-pump coil goes on the supply or return side, up to 3 tons. Dettson does require non-simultaneous operation, though: the thermostat runs either the heat pump or the elements, never both at once.

Why choose the ECM motor over the PSC version?

The 1/2 HP ECM motor lets the airflow be set separately for heating and for cooling, and Dettson covers it for 5 years. The PSC version in the series, the SUP18-A240D12, uses a direct-drive motor.

What electrical circuit is needed?

A 100 A maximum breaker at 240 V (90 A at 208 V). Dettson publishes a 94.7 A ampacity and a 78.1 A total current at 240 V.

How warm is the air at the registers?

Dettson publishes a 65 °F temperature rise at 240 V between the return air and the supply air.

Does it qualify for a grant?

No. Sold alone, an electric furnace is not a heat pump and does not qualify for the LogisVert grant.

What is the manufacturer warranty?

Parts for 5 years in residential use and 1 year in commercial use; ECM motor for 5 years. Labour is not covered by Dettson.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

An 18 kW Suprême Avantage ECM, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.